1. Муқаддима
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Savio WMS3600 Water Master Solids Submersible Pump. Please read these instructions thoroughly before use to ensure proper function and longevity of the product.

Image 1.1: Savio WMS3600 Water Master Solids Submersible Pump. This image displays the main unit of the submersible pump, highlighting its compact, black, cylindrical design with an integrated handle and a side outlet.
2. Маълумот оид ба бехатарӣ
Always observe the following safety precautions to reduce the risk of injury, electric shock, or product damage:
- Бехатарии барқ: Ensure the pump is connected to a properly grounded outlet protected by a Ground Fault Circuit Interrupter (GFCI). Do not operate the pump if the power cord is damaged.
- Оббоварӣ: This pump is designed for submersible use only. Do not operate it dry.
- Муносибат: Always disconnect power before handling, installing, or performing maintenance on the pump. Do not lift the pump by its power cord.
- Ҳарорати об: Do not use the pump in water exceeding 95°F (35°C).
- Истифодаи таъиншуда: Use this pump only for its intended purpose of circulating water in ponds and water features, handling solids up to 1 inch in diameter.
3. Хусусиятҳои маҳсулот
The Savio WMS3600 pump incorporates several design elements for reliable performance:
- Муносибати сахт: Capable of handling solids up to 1 inch in diameter, making it suitable for pond filtration and waterfalls.
- Сохтмони устувор: Features a ceramic-coated drive shaft and triple silicon carbide mechanical seals for extended operational life.
- Муҳофизати автомобилҳо: Equipped with a precision-manufactured motor that includes thermal overload protection to prevent damage from overheating.
- Oil-Less Design: Safe for aquatic environments, including those with fish and plants.
- Non-Corrosive Housing: The pump's exterior is constructed from non-corrosive materials.

Image 3.1: Key features of the Savio WMS3600 pump. This image highlights the non-corrosive housing and the 1.25-inch output, along with text descriptions for solids handling, thermal overload protection, and factory testing.
4. Танзим ва насб
Follow these steps for proper installation of your submersible pump:
- Кушодани: Carefully remove the pump from its packaging. Inspect for any visible damage.
- Ҷойгиршавӣ: Position the pump on a stable, level surface within the pond or water feature. Ensure it is fully submerged and not resting directly on the bottom sediment. Using a pump stand or elevated platform is recommended to prevent clogging from debris.
- Пайвастшавии шланг: Connect appropriate hosing to the pump's outlet. The pump features a 1-1/2" outlet (with elbow). Secure the hose with a clamp барои пешгирии ихроҷ.
- Пайвастагии барқ: Route the power cord safely to a GFCI-protected electrical outlet. Ensure the cord is not pinched or damaged. Do not use extension cords unless specifically rated for outdoor, wet conditions and properly grounded.
- Санҷиши ибтидоӣ: Before powering on, ensure all connections are secure and the pump is fully submerged in water.
5. Амалиёт
Operating your Savio WMS3600 pump is straightforward:
- Фаъол: Plug the pump into the GFCI-protected outlet. The pump should start immediately, circulating water.
- Мониторинги ҷараёни: Observe the water flow to ensure it is consistent and free of obstructions.
- Фаъолияти доимӣ: This pump is designed for continuous operation. However, regular checks for debris accumulation are recommended.
- Пӯшида шудан: To turn off the pump, simply unplug it from the electrical outlet.
6. Нигоҳдорӣ
Regular maintenance ensures optimal performance and extends the life of your pump:
- Хомӯш кардани барқ: Always unplug the pump before performing any maintenance.
- Clean Impeller and Housing: Periodically remove the pump from the water and inspect the impeller and pump housing for debris such as leaves, algae, or small stones. Clean these components using a soft brush and water.
- Сими барқро тафтиш кунед: Inspect the power cord for any signs of wear, cuts, or damage. Replace if necessary.
- Зимистонгузаронӣ: In regions with freezing temperatures, remove the pump from the pond before the first freeze. Clean it thoroughly and store it in a frost-free location, submerged in a bucket of water to keep seals lubricated, or follow manufacturer's specific winterization guidelines.
7. Баррасии мушкилот
Барои масъалаҳои умумӣ ва роҳҳои ҳалли онҳо ба ин бахш муроҷиат кунед:
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Pump does not start or operate. | No power; GFCI tripped; clogged impeller; motor overload. | Check power connection and GFCI. Disconnect power, clear impeller, allow motor to cool if overloaded. |
| Кам шудани ҷараёни об. | Clogged intake or impeller; kinked or obstructed hose; low water level. | Disconnect power, clean intake and impeller. Check hose for obstructions. Ensure pump is fully submerged. |
| Pump runs but no water flows. | Air lock; completely blocked intake/impeller. | Disconnect power, remove pump, shake gently to release air, re-submerge. Clear any severe blockages. |
| Pump trips GFCI repeatedly. | Electrical fault; damaged cord; water in motor housing. | Inspect cord for damage. If problem persists, discontinue use and contact qualified service personnel. |
8. Мушаххасоти
Detailed technical specifications for the Savio WMS3600 Water Master Solids Submersible Pump:
| Аттрибут | Арзиш |
|---|---|
| Модели | WMS3600 |
| Бренд | Савио |
| Суръати ҳадди аксар | 3,600 GPH (60 Gallons Per Minute) |
| Диапазони оптималии амалиёт | 1440 gph - 2880 gph |
| Максимум сар | 25 фут |
| Ҷилдиtage | 115 вольт |
| Ватtage | 650 Ватт |
| Ampнест кардан | 6 Amps |
| Герц | 60 Гц |
| Андозаи баромад | 1-1/2" (with elbow) |
| Муомилоти сахт | То 1 дюйм |
| Андозаҳо (L x W x H) | 10 x 8 x 14 дюйм (тақрибан) |
| Вазни ашё | 8 фунт |
| Дарозии сим | 16 фут |
| Материал | Пластмасса |
| Манбаи нерӯ | AC |
| Ранги | Сиёҳ |

Image 8.1: Savio WMS3600 pump with approximate dimensions. The image shows the pump with labels indicating a height of 13"-14" and a width of 6".
Диаграммаҳои иҷроиш

Image 8.2: Savio Water Master Solids Specifications Chart. This chart provides detailed specifications for various WMS models, including dimensions, amps, watts, volts, outlet size, hertz, max flow, optimal operating range, max head, and average monthly operating cost.

Image 8.3: Water Master Solids Flow Rates (gallons per hour) versus Max Head Pressure (in feet) chart. This graph illustrates the performance curves for different Savio WMS pump models (WMS1450, WMS2050, WMS3600, WMS5000, WMS6500).

Image 8.4: Comparative specifications table for Savio Water Master Solids Pumps. This table lists pump model, dimensions, max flow, cord length, watts, volts, amps, and max head for various models.
9. Кафолат ва дастгирӣ
The Savio WMS3600 Water Master Solids Submersible Pump comes with a Кафолати 2-солаи истеҳсолкунанда. For warranty claims or technical support, please contact Savio customer service directly. Retain your proof of purchase for warranty validation.
For additional information or to locate authorized service centers, please visit the official Savio webсомона ё ба маълумоти тамос муроҷиат кунед, ки бо бастаи маҳсулоти шумо оварда шудааст.