Juniper Networks EX2200-24T-4G

Дастури корбарии коммутатори қабати 3-юми Juniper EX2200-24T-4G

Model: EX2200-24T-4G

1. Муқаддима

This manual provides essential information for the installation, operation, and maintenance of your Juniper EX2200-24T-4G Layer 3 Switch. The EX2200 series switches are designed to deliver high-performance, wire-rate forwarding capabilities, even with advanced control plane features enabled. This device incorporates an application-specific integrated circuit (ASIC)-based Packet Forwarding Engine (PFE) with an integrated CPU, ensuring consistent performance and reliability.

2. Маҳсулот ба охир расидview

The Juniper EX2200-24T-4G is a compact, high-performance Layer 3 Ethernet switch. It features 24 10/100/1000BASE-T Gigabit Ethernet ports for network connectivity and 4 Gigabit Ethernet SFP (Small Form-Factor Pluggable) uplink ports for fiber optic connections to other network devices or the core network.

Пеш view of the Juniper EX2200-24T-4G Layer 3 Switch, showing 24 RJ45 Ethernet ports and 4 SFP uplink ports.

Расми 1: Front panel of the Juniper EX2200-24T-4G switch. This image displays the front panel of the Juniper EX2200-24T-4G switch. It features 24 RJ45 Gigabit Ethernet ports, numbered 0 through 23, arranged in two rows. To the right, there are four SFP (Small Form-Factor Pluggable) uplink ports, typically used for fiber optic connections. Status LEDs for system (SYS), alarm (ALM), speed (SPD), duplex (DX), enable (EN), and Power over Ethernet (POE) are also visible on the right side. Note that this specific model (EX2200-24T-4G) does not support PoE.

2.1 Хусусиятҳои асосӣ

  • 24 x 10/100/1000BASE-T Ethernet ports
  • 4 x Gigabit Ethernet SFP uplink ports
  • Layer 3 switching capabilities
  • Junos operating system
  • Тарҳи паймоне 1U, ки ба rack васлшаванда

3. Танзимот

3.1 Кушодани баста

Carefully remove the switch and all accessories from the packaging. Verify that all components listed in the packing list are present. Retain the packaging materials for future use or transport.

3.2 Васлкунӣ

The EX2200-24T-4G switch can be deployed as a desktop unit or rack-mounted. For rack mounting, use the provided rack-mount kit and secure the switch in a standard 19-inch equipment rack. Ensure adequate airflow around the device for proper cooling.

3.3 Пайваст кардани қувваи барқ

  1. Connect one end of the provided AC power cord to the AC power receptacle on the rear panel of the switch.
  2. Connect the other end of the power cord to a grounded AC power outlet.
  3. Ensure the power source provides the correct voltagд (240 вольт).

3.4 Пайваст кардани кабелҳои шабакавӣ

  • Портҳои RJ45: Connect standard Ethernet cables (Cat5e or higher) from your network devices (computers, servers, access points) to the 24 RJ45 ports on the front panel.
  • SFP Uplink Ports: Insert compatible SFP transceivers into the 4 SFP uplink ports. Connect fiber optic cables from these transceivers to your core network or other switches.

3.5 Дастрасии ибтидоии конфигуратсия

To perform initial configuration, connect a console cable (RJ-45 to DB-9) from your management workstation to the console port on the switch. Use a terminal emulation program (e.g., PuTTY, Tera Term) with the following settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control. Alternatively, if the switch has a default management IP, you can connect via a web browser or SSH after basic network connectivity is established.

4. Амалиёт

4.1 Фаъол кардан/хомӯш кардан

Once the power cord is connected, the switch will automatically power on. There is no separate power button. To power off, disconnect the power cord from the AC outlet.

4.2 Нишондиҳандаҳои LED

The front panel LEDs provide status information about the switch and its ports:

  • SYS (Система): Indicates overall system status. Green for normal operation, amber for a fault.
  • ALM (Ҳушдор): Ҳолати ҳушдорро нишон медиҳад.
  • SPD (Суръат): Indicates the link speed of the corresponding port.
  • DX (Дуплекс): Indicates the duplex mode (half or full) of the corresponding port.
  • EN (Фаъол): Indicates if the port is enabled.
  • POE (Power over Ethernet): This LED is present but not functional on the EX2200-24T-4G model as it does not support PoE.

4.3 Junos OS

The switch runs on Juniper Networks' Junos operating system. Configuration and management are primarily performed via the command-line interface (CLI) accessible through the console port or SSH. Junos provides a robust and feature-rich environment for network management.

5. Нигоҳдорӣ

5.1 Тозакунӣ

Keep the switch clean and free of dust. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners directly on the device. Ensure ventilation openings are clear of obstructions.

5.2 Навсозии нармафзор

Дастгирии Juniper Networks-ро мунтазам тафтиш кунед website for available Junos OS updates. Firmware updates can provide new features, performance enhancements, and security patches. Follow the instructions provided by Juniper Networks for the update process.

5.3 Мулоҳизаҳои муҳити зист

Operate the switch within its specified environmental limits (temperature, humidity). Ensure proper ventilation to prevent overheating. Avoid exposing the device to direct sunlight, excessive moisture, or extreme temperatures.

6. Баррасии мушкилот

6.1 Не қудрат

  • Verify the power cord is securely connected to both the switch and the AC outlet.
  • Васлаки барқро бо дастгоҳи дигар санҷед, то боварӣ ҳосил кунед, ки он кор мекунад.
  • Боварӣ ҳосил кунед, ки манбаи барқ ​​voltage matches the switch's requirements (240 Volts).

6.2 Пайванд дар Порт нест

  • Сими Ethernet-ро аз ҷиҳати осеб тафтиш кунед ва боварӣ ҳосил кунед, ки он ҳам дар порти коммутатор ва ҳам дар дастгоҳи пайвастшуда дуруст ҷойгир шудааст.
  • Боварӣ ҳосил кунед, ки дастгоҳи пайвастшуда фурӯзон аст ва дуруст кор мекунад.
  • Check the port configuration in Junos OS to ensure it is enabled and correctly configured.
  • For SFP ports, ensure the transceiver is correctly inserted and compatible, and the fiber optic cable is clean and undamaged.

6.3 System Alarm (ALM LED)

If the ALM LED is lit, consult the Junos OS documentation or the Juniper Networks support website for specific alarm codes and recommended actions. This typically indicates a hardware fault or a critical system event.

7. Мушаххасоти

ХусусиятМушаххасоти
Рақами моделEX2200-24T-4G
БрендШабакаҳои Juniper
Портҳои Ethernet24 x 10/100/1000BASE-T (RJ45)
Портҳои Uplink4 x Gigabit Ethernet SFP
Навъи интерфейсRJ45, SFP
Меъёри интиқоли маълумот1000 Мегабит дар як сония
Низоми амалЮнос
Ҷилдиtage240 вольт
Андозаҳои маҳсулот (LxWxH)10 x 17.4 x 1.75 инч
Вазни ашё6 фунт
Компонентҳои дохилшудаSwitch, Accessories
Истеҳсолкунандаарча
UPC832938043305

8. Дастгирӣ ва кафолат

8.1 Дастгирии техникӣ

For technical assistance, documentation, and software downloads, please visit the official Juniper Networks support website. You can find resources such as knowledge base articles, community forums, and contact information for customer support.

8.2 Кафолати маҳсулот

This Juniper Networks product is covered by a standard manufacturer's warranty. Details regarding the warranty period and terms can be found on the Juniper Networks official website or in the warranty documentation included with your purchase. Please retain your proof of purchase for warranty claims.

Ҳуҷҷатҳои марбут - EX2200-24T-4G

Пешview Juniper Networks Junos OS for EX Series Ethernet Switches: Power over Ethernet (PoE) Guide
This document provides comprehensive information on configuring and managing Power over Ethernet (PoE) for Juniper Networks EX Series Ethernet Switches running Junos OS. It covers an overview of PoE, configuration tasks, administration, and troubleshooting.
Пешview Juniper EX3300 Switch Hardware Guide
This guide provides comprehensive information on the Juniper Networks EX3300 Ethernet Switch hardware, covering installation, configuration, maintenance, and troubleshooting. Learn about system overview, chassis components, power, cooling, site planning, and safety guidelines for the EX3300 series.
Пешview Junos OS барои гузаришҳои EX Series Ethernet: Дастури конфигуратсияи виртуалии шасси
Ин ҳуҷҷат тафсилоти мукаммали конфигуратсия ва фармонҳои амалиётиро барои коммутаторҳои Ethernet-и силсилаи Juniper Networks EX пешниҳод мекунад, ки ба татбиқ ва идоракунии технологияи шасси виртуалӣ нигаронида шудааст. Он танзимот, ҳалли мушкилот ва хусусиятҳои пешрафтаро барои моделҳои EX2200, EX3300, EX4200, EX4500 ва EX4550 фаро мегирад.
Пешview Дастури сахтафзори коммутатори Juniper EX3400: Насб, танзим ва нигоҳдорӣ
Дастури мукаммали сахтафзор барои коммутаторҳои Ethernet силсилаи Juniper Networks EX3400, ки насб, васлкунӣ, барқ, пайвастшавӣ, нигоҳдорӣ, ҳалли мушкилот ва бехатариро барои ҷойгиркунии шабакаҳои корхонаӣ дар бар мегирад.
Пешview Дастури сахтафзори коммутатори Juper Networks EX2300: Насб ва танзимот
Дастури мукаммали сахтафзор барои коммутаторҳои Ethernet-и Juniper Networks EX2300. Дар бораи насб, танзим, нигоҳдорӣ ва ҳалли мушкилоти шабакавии корхона ва маркази додаҳо маълумот гиред.
Пешview Коммутаторҳои Ethernet-и Juniper EX4300: Варақаи маълумот
Варақаи иттилоотии мукаммал барои коммутаторҳои Ethernet силсилаи Juniper EX4300, хусусиятҳои муфассал, мушаххасот, технологияи шасси виртуалӣ ва имконоти идоракунӣ барои корхонаҳоampшабакаҳои маркази додаҳо ва ИМА.