The Dwyer Series WMT2 Multi-Jet Water Meter is engineered for commercial and industrial applications requiring accurate water flow measurement. Its multi-jet design ensures reliable performance and accuracy across a broad range of flow rates, including low-flow conditions. The meter is built for durability and minimal maintenance, even in challenging environments. It features a magnetically driven, hermetically sealed register that prevents leaks and fogging, completely isolating it from the water flow. A reed switch, activated by a magnet on the dial, generates a pulsed output directly proportional to the flow rate. This output is suitable for remote monitoring of flow rate or totalization and can be integrated with PLCs, counters, data loggers, and SCADA systems.

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output

Image 1.1: The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter, showing its brass body, blue casing, and the meter face with a pulsed output connection.

2. Маълумот оид ба бехатарӣ

WARNING: This product is NOT FOR POTABLE WATER USE. The brass construction contains lead in excess of low-lead limits. Do not use this meter in applications where water will be consumed by humans or animals.

Always ensure proper installation by qualified personnel to prevent leaks and ensure accurate operation. Adhere to all local codes and regulations regarding plumbing and electrical connections.

3. Хусусиятҳои маҳсулот

  • Multi-Jet Design: Provides high accuracy and wide flow range capabilities.
  • Pulsed Output: Equipped with a reed switch for remote monitoring and integration with control systems.
  • Hermetically Sealed Register: Magnetically driven, preventing leaks and fogging for clear readings.
  • Сохтмони устувор: Designed for long service life in commercial and industrial settings.
  • Бадани биринҷӣ: Robust construction for demanding applications.

4. Мушаххасоти

МушаххасотиАрзиш
МоделиWMT2-B-C-11-1
Андозаи пайвастшавӣ1" BSPT
Суръати ҳадди аксар7 м³/соат
Меъёри номиналӣ0.25 то 3.5 м³/соат
Transitional Flow Rate0.07 м³/соат
Меъёри набзи1 gallon per pulse
Ҳарорати максималӣ104°F (40°C)
Фишори максималӣ232 psi (16 бар)
Пайвастҳои барқӣColor-coded lead wires, 4.5' (1.5 m) long
Вазни ашё13.52 фунт
ИстеҳсолкунандаDwyer Instruments, Inc.

5. Танзим ва насб

Installation of the Dwyer WMT2-B-C-11-1 water meter should be performed by a qualified professional in accordance with all applicable local and national plumbing and electrical codes.

  1. Интихоби макон: Choose a location that is easily accessible for reading and maintenance, protected from freezing temperatures, and where the meter can be installed horizontally with the flow arrow pointing in the direction of water flow.
  2. Омодасозии қубур: Ensure the piping is clean and free of debris before installation. Use appropriate pipe thread sealant on the 1" BSPT couplings.
  3. Насби механикӣ: Install the meter into the pipeline, ensuring a tight, leak-free connection. The meter should be installed in a straight run of pipe, ideally with at least 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream for optimal accuracy.
  4. Пайвастагии барқ: Connect the color-coded lead wires from the pulsed output to your remote monitoring system (PLC, counter, data logger, SCADA). Refer to your system's documentation for specific wiring requirements. Ensure all electrical connections are secure and properly insulated.
  5. Санҷиши ихроҷ: After installation, slowly open the water supply to the meter and check for any leaks at the connections.

6. Дастурҳои истифодабарӣ

Once installed and the water supply is restored, the Dwyer WMT2-B-C-11-1 meter will begin measuring water flow. The meter's register displays the totalized volume of water that has passed through it. The pulsed output provides an electrical signal (1 pulse per gallon) that can be used by external devices for remote monitoring and data logging.

  • Reading the Meter: The main display on the meter face shows the total accumulated volume. Smaller dials may indicate fractional units for more precise readings.
  • Pulsed Output: The reed switch generates a pulse for every gallon of water that flows through the meter. Connect the lead wires to a compatible device (e.g., PLC, counter) to record these pulses and calculate flow rate or total volume remotely.
  • Самти ҷараён: Ensure water flows in the direction indicated by the arrow on the meter body for accurate measurement.

7. Нигоҳдорӣ

The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter is designed for relatively maintenance-free operation. However, periodic checks are recommended to ensure continued accuracy and performance:

  • Санҷиши визуалӣ: Regularly inspect the meter for any signs of physical damage, leaks, or corrosion.
  • Register Clarity: Ensure the hermetically sealed register remains clear and free of fogging, allowing for easy reading.
  • Ягонагии пайвастшавӣ: Verify that all plumbing and electrical connections remain secure and free of corrosion.
  • Тозакунӣ: If the exterior of the meter becomes dirty, wipe it with a damp матоъ. Моддаҳои кимиёвии сахт ё тозакунандаи абразивиро истифода набаред.

No internal user-serviceable parts are present. Do not attempt to disassemble the meter, as this will void the warranty and may damage the device.

8. Баррасии мушкилот

If you encounter issues with your Dwyer WMT2-B-C-11-1 water meter, consider the following troubleshooting steps:

  • No Flow Reading:
    • Check if water is actually flowing through the pipe.
    • Verify the meter is installed with the flow arrow in the correct direction.
    • Inspect for any blockages upstream or downstream of the meter.
  • Хонишҳои нодуруст:
    • Ensure the meter is installed horizontally.
    • Check for air in the pipeline, which can affect accuracy.
    • Verify that the flow rate is within the meter's specified nominal flow range.
  • No Pulsed Output:
    • Confirm that water is flowing through the meter and the mechanical register is advancing.
    • Check the electrical connections of the lead wires to your monitoring device.
    • Ensure the monitoring device is correctly configured to receive pulses.
  • Ихроҷ дар пайвастшавӣ:
    • Tighten connections carefully, ensuring not to overtighten.
    • If necessary, drain the system, reapply pipe thread sealant, and reassemble.

If problems persist after performing these checks, contact Dwyer Instruments, Inc. technical support for assistance.

9. Кафолат ва дастгирӣ

For information regarding the product warranty, technical support, or replacement parts, please contact Dwyer Instruments, Inc. directly or visit their official website. Keep your purchase receipt and product model number (WMT2-B-C-11-1) readily available when seeking support.

Ҳуҷҷатҳои марбут - WMT2-B-C-11-1

Пешview Dwyer Series 477AV манометри дастӣ: Мушаххасот, насб ва дастурҳои истифода
Дастури ҳамаҷониба ба манометри рақамии дастии Dwyer Series 477AV, ки хусусиятҳо, насб, дастурҳои истифода, хусусиятҳо ва нигоҳдорӣ барои андозагирии фишор, ҷараён ва суръатро дар бар мегирад.
Пешview Силсилаи Dwyer IEF интиқолдиҳандаи ҷараёни электромагнитӣ: Дастурҳои насб ва истифода
Ин ҳуҷҷат тавсифи ҳамаҷониба, дастурҳои насб ва дастурҳои истифодабарии интиқолдиҳандаи ҷараёни электромагнитии Dwyer Series IEF-ро дар бар мегирад, ки хусусиятҳо, барномаҳо ва протоколҳои иртиботиро барои андозагирии суръати моеъи саноатӣ муфассал шарҳ медиҳад.
Пешview Маҳсулоти андозагирӣ ва назорати ҷараёни Dwyer: Дастури мукаммали интихоб
Explore Dwyer Instruments' extensive range of flowmeters, flow switches, and flow transmitters. This guide provides detailed specifications and selection criteria to help identify the optimal product for your industrial or commercial application.
Пешview Dwyer Series VFC Visi-Float Flowmeters Дастури оғози зуд
Дастури зуд барои оғозёбӣ барои Dwyer Series VFC Visi-Float Flowmeters, ки дастурҳои муҳими насбкунӣ, васлкунӣ ва хонданро дар якҷоягӣ бо огоҳиҳои муҳими амалиётӣ таъмин мекунад.
Пешview Ҳисобкунакҳои энергетикии ултрасадои Dwyer Series TUF: Мониторинги ҷараён ва ҳарорат
Мушаххасоти муфассал, хусусиятҳо, барномаҳо ва маълумоти фармоишӣ барои Ҳисобкунакҳои энергияи ултрасадои Dwyer Series TUF, ки барои мониторинги дақиқи ҷараён ва ҳарорат бо алоқаи Modbus® ё BACnet тарҳрезӣ шудаанд.
Пешview Барномаҳо ва дастурҳои интихоби маҳсулоти автоматикунонии равандҳои Dwyer
Дастури ҳамаҷонибаи Dwyer Instruments-ро оид ба автоматикунонии равандҳо, ки татбиқи маҳсулот ва интихоби HVAC, коркарди об, нафт ва газ ва ғайраро дар бар мегирад, омӯзед. Роҳҳои ҳалли асбобҳоро барои фишор, ҷараён, сатҳ, ҳарорат ва сифати ҳаво кашф кунед.