Муқаддима
This manual provides essential information for the proper installation, operation, and maintenance of the Cleveland 110198 Motor Driven Timer. This is a genuine OEM replacement part designed for specific Cleveland steam cooking equipment and foodservice applications. Adhering to these instructions will ensure safe, reliable, and optimal performance of the timer.
Маълумоти муҳим оид ба бехатарӣ
- Ҳамеша барқро ҷудо кунед to the equipment before installing, servicing, or removing the timer.
- Installation and service should only be performed by qualified personnel.
- Танҳо истифода баред genuine Cleveland OEM parts for replacement to ensure compatibility and safety.
- Refer to the main equipment's service manual for specific wiring diagrams and safety precautions.
- Do not operate the equipment if the timer is damaged or malfunctioning.
Мундариҷаи баста
Боварӣ ҳосил кунед, ки ҳамаи ҷузъҳо ҳангоми кушодан мавҷуданд:
- 1 x Cleveland 110198 Motor Driven Timer
- (Note: Additional mounting hardware or connectors may be required and are sold separately or are part of the main equipment.)
Маҳсулот ба охир расидview
The Cleveland 110198 Motor Driven Timer is a mechanical timing device designed for integration into various foodservice equipment. Below is an image of the timer for identification.

Расми 1: Cleveland 110198 Motor Driven Timer. This image shows the timer unit with its motor, metal mounting plate, output shaft, and electrical leads. The label indicates "PRECISION TIMER" and model number "#110198".
Насб ва насб
Follow these steps carefully for proper installation:
- Қатъи барқ: Ensure the main power supply to the equipment is completely disconnected and locked out before beginning installation.
- Дастрасӣ: Locate the existing timer or the designated mounting area within the equipment.
- Removal (if replacing): Carefully disconnect the electrical leads from the old timer. Remove any mounting screws or clips securing the old timer.
- Монтаж: Position the new Cleveland 110198 timer in the designated location. Secure it using appropriate mounting hardware (not included). Ensure the timer is firmly seated and does not vibrate.
- Ноқил: Connect the electrical leads to the new timer according to the equipment's wiring diagram. Ensure all connections are secure and properly insulated. Refer to the equipment's service manual for specific wiring instructions.
- Тафтиш: Double-check all connections and ensure no loose wires or obstructions are present.
- Барқарорсозии барқ: Restore power to the equipment.
Дастурҳои амалиётӣ
The Cleveland 110198 is a motor-driven mechanical timer. Its operation is typically integrated into the larger control system of the equipment it is installed in.
- Функсия: This timer is designed to control specific operational cycles within the equipment, such as cooking times or process durations.
- Танзимот: The timer features 2 settings, which are typically configured by the equipment's main control panel or internal adjustments. Refer to your equipment's user manual for how to set or adjust the timing cycles.
- Фаъолсозӣ: The timer activates when power is supplied to its motor, initiating a countdown or timed cycle.
- Натиҷа: Upon completion of the timed cycle, the timer will trigger an internal switch, signaling the equipment's control system to proceed to the next step or shut off a function.
Нигоҳдорӣ
The Cleveland 110198 Motor Driven Timer is designed for durability and requires minimal maintenance.
- Санҷиши мунтазам: Periodically inspect the timer and its connections for any signs of wear, damage, or corrosion.
- Тозакунӣ: Keep the area around the timer clean and free from dust, grease, or debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
- Хизматрасонии касбӣ: If the timer exhibits erratic behavior or fails to function correctly, contact qualified service personnel for diagnosis and repair. Do not attempt to disassemble the timer.
Мушкилкушо
Барои масъалаҳои умумӣ ва роҳҳои ҳалли эҳтимолии онҳо ба ҷадвали зер муроҷиат кунед.
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Timer does not activate. | No power supply; Loose wiring connection; Faulty timer motor. | Check equipment power supply. Verify all wiring connections are secure. If power is present and wiring is correct, the timer may need replacement by a qualified technician. |
| Timer runs continuously or stops prematurely. | Internal mechanical fault; Incorrect equipment settings. | Consult the equipment's user manual for correct timer settings. If the issue persists, the timer likely requires replacement by a qualified technician. |
| Inaccurate timing. | Worn internal components; Electrical interference. | Ensure the timer is not exposed to excessive heat or vibration. If accuracy issues persist, replacement by a qualified technician is recommended. |
Мушаххасоти
- Бренд: КЛИВленд
- Рақами модел: 110198
- Навъи: Motor Driven Timer
- Мавод: Plastic (housing/internal components)
- Шумораи Танзимот: 2
- Вазни ашё: Тақрибан 1.6 унс (0.1 фунт)
- Андозаҳои маҳсулот: Approximately 5 x 5 x 8 inches (packaging/overall size)
- UPC: 088308265338, 421524042152
- Компонентҳои дохилшуда: Қисми иваз
- Батареяҳои зарурӣ: Не
Кафолат ва дастгирӣ
As a genuine OEM replacement part, the Cleveland 110198 Motor Driven Timer is typically covered by the warranty of the original equipment manufacturer. Please refer to the warranty documentation provided with your Cleveland equipment for specific terms and conditions.
For technical assistance, replacement parts, or service inquiries, please contact your authorized Cleveland service provider or the equipment manufacturer directly. Using genuine OEM parts helps maintain your equipment's warranty and ensures safety and reliability.
Маълумот барои тамос: Please refer to your original equipment documentation for the most current customer support contact details.