Dante NG.BVS.CR

Дастури корбарии маҷмӯаи универсалии оташгирандаи чӯбӣ аз Dante Products NG.BVS.CR

Model: NG.BVS.CR

Муқаддима

This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of the Dante Products NG.BVS.CR Universal Log Lighter Combo Kit. This kit is designed to provide a convenient and clean method for igniting natural gas logs in a fireplace.

Лутфан пеш аз насб ва истифода ҳама дастурҳоро бодиққат хонед. Ин дастурро барои истинод дар оянда нигоҳ доред.

Қисмҳои маҳсулот

The Dante Universal Log Lighter Combo Kit includes the following components:

Dante Products NG.BVS.CR Universal Log Lighter Combo Kit components: a chrome key, a chrome floor plate, a long gas log lighter tube with a mixer, and a brass T-fitting.

Расми 1: Барview of the Dante Universal Log Lighter Combo Kit components. This image displays all parts included in the kit: a chrome-plated key for operating the valve, a circular chrome floor plate that covers the valve opening, a long metal tube which is the natural gas log lighter with an attached mixer at one end, and a brass T-fitting for gas line connection.

  • Natural Gas Log Lighter: A 20-inch long tube with an integrated air/gas mixing chamber, designed for efficient gas combustion.
  • Quarter-Turn Ball Valve: A straight 1/2-inch valve for controlling gas flow.
  • Chrome Floor Plate: A decorative zinc die-cast, chrome-plated plate to cover the valve opening.
  • 3-Inch Key: A zinc die-cast, chrome-plated key for operating the quarter-turn ball valve.
  • Brass T-Fitting: For connecting the gas supply line.

Насб ва насб

Маълумоти муҳим оид ба бехатарӣ: Installation must be performed by a qualified professional in accordance with all local codes and regulations. Ensure the main gas supply is turned off before beginning installation.

  1. Prepare Fireplace: Ensure the fireplace is clean and free of debris. Identify the location for the gas line connection.
  2. Хати газро пайваст кунед: Connect the natural gas supply line to the brass T-fitting. Use appropriate pipe sealant on all threaded connections to prevent leaks.
  3. Install Ball Valve: Attach the quarter-turn ball valve to the T-fitting. Ensure it is securely tightened.
  4. Position Log Lighter: Connect the natural gas log lighter tube to the ball valve. Position the log lighter within the fireplace, ensuring the burner holes face upwards and are clear of any obstructions. The log lighter measures 20 inches from end to end with the mixer attached.
  5. Пластинаи фаршро насб кунед: Place the chrome floor plate over the valve stem opening in the hearth or floor, ensuring it sits flush.
  6. Санҷиш барои ихроҷ: After all connections are made, slowly turn on the main gas supply. Apply a leak detection solution (soapy water) to all connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, tighten connections, and re-test. Do not proceed until all leaks are resolved.
  7. Place Gas Logs: Arrange your gas logs over the log lighter, ensuring they do not block the burner holes or the air/gas mixing chamber. Allow adequate air circulation around the log lighter.

Дастурҳои амалиётӣ

Аввалин бехатарӣ: Always ensure proper ventilation when operating gas appliances. Never leave an active flame unattended.

  1. Open Dampэ: Ensure the fireplace damper is fully open before lighting to allow for proper ventilation and prevent smoke from entering the room. The log lighter heats the chimney quickly, causing the fireplace to draw smoke immediately up the chimney.
  2. Калидро ворид кунед: Insert the 3-inch chrome key into the quarter-turn ball valve stem.
  3. Turn On Gas: Slowly turn the key to the "ON" position (typically a quarter-turn). You should hear the sound of gas flowing.
  4. Ignite Gas: Immediately use a long fireplace lighter or match to ignite the gas flowing from the log lighter. The flame should be visible and consistent.
  5. Танзими оташ: Once the logs are ignited, you can adjust the flame intensity by partially turning the key towards the "OFF" position. For full ignition of logs, allow the log lighter to burn for a few minutes until the logs are sufficiently lit.
  6. Turn Off Log Lighter: Once the gas logs are burning steadily, turn the key to the "OFF" position to extinguish the log lighter flame. Remove the key.

Нигоҳдорӣ

The Dante Universal Log Lighter Combo Kit requires minimal maintenance. Regular inspection is recommended to ensure safe and efficient operation.

  • Санҷиши солона: Have a qualified professional inspect the gas connections and the log lighter annually for any signs of wear, corrosion, or leaks.
  • Clean Burner Holes: Periodically check the burner holes on the log lighter tube for any obstructions (e.g., soot, debris). Use a small brush or wire to clear them if necessary. Ensure the gas supply is off before cleaning.
  • Компонентҳои тоза: Wipe down the chrome floor plate and key with a soft, damp cloth to maintain their appearance. Avoid abrasive cleaners.

Мушкилкушо

Мушкилот Сабаби эҳтимолӣ Ҳалли
No gas flow or weak flame.
  • Таъмини гази асосӣ қатъ шудааст.
  • Valve not fully open.
  • Gas line obstruction.
  • Клапани асосии таъминоти газро тафтиш кунед.
  • Боварӣ ҳосил кунед, ки калид пурра ба ҳолати "ON" гардонида шудааст.
  • Contact a qualified technician to inspect gas lines.
Бӯи газ муайян карда шуд.
  • Gas leak at connections.
  • Valve not fully closed.
  • Immediately turn off gas supply. Ventilate area. Apply leak detection solution to all connections. Tighten or repair as needed. If smell persists, evacuate and call gas company.
  • Ensure key is fully turned to "OFF" and removed.
Log lighter does not ignite.
  • No gas flow (see above).
  • Ignition source not applied quickly enough.
  • Burner holes obstructed.
  • Follow steps for "No gas flow".
  • Apply ignition source immediately after turning on gas.
  • Clean burner holes (ensure gas is off).

Агар қадамҳои ислоҳи мушкилот ҳалли худро наёбанд, бо мутахассиси соҳаи хизматрасонӣ тамос гиред.

Мушаххасоти

Рақами модел NG.BVS.CR
Бренд Dante Products
Навъи сӯзишворӣ Гази табиӣ (NG)
Log Lighter Length 20 inches (end to end with mixer)
Рейтинги BTU 30,000 БТУ
Андоза халќи 1/2-inch (straight quarter-turn ball valve)
Material (Key & Floor Plate) Zinc Die-Cast, Chrome Plated
Андозаҳои умумӣ 24 x 3 x 3 инч
Вазни ашё 3 фунт
Маҷлис талаб карда мешавад Бале
Батареяҳо лозиманд Не

Маълумот дар бораи кафолат

The Dante Products NG.BVS.CR Universal Log Lighter Combo Kit comes with a Кафолати 1 солаи маҳдуд аз рӯзи харид.

This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repairs. For warranty claims, please retain your proof of purchase and contact Dante Products customer support.

Дастгирии муштариён

For technical assistance, replacement parts, or warranty inquiries, please contact Dante Products customer support.

Please have your model number (NG.BVS.CR) and proof of purchase available when contacting support.

For additional information and resources, you may visit the official Dante Products website (if available, link would be here).

Истеҳсолкунанда: Dante Products

Ҳуҷҷатҳои марбут - NG.BVS.CR

Пешview Дастури соҳиби оташдон гармкунаки барқӣ ва дастури насби Dante
Дастури ҳамаҷонибаи соҳиб ва дастури насб барои гармкунаки барқии оташдонҳои Dante Flat Panel (Модели EFW-TJ42A), ки бехатарӣ, истифода, васлкунӣ ва ҳалли мушкилотро дар бар мегирад.
Пешview Данте Саволҳо оид ба ҳалли мушкилот: Роҳҳо барои масъалаҳои маъмулии шабакаҳои аудиоӣ
Ин дастури ҳамаҷонибаи FAQ барои мушкилоти умумӣ бо шабакаи аудиоии Данте, аз ҷумла Данте Контроллер ва Корти садоии виртуалии Данте, роҳҳо ва тавзеҳотро пешниҳод мекунад. Омӯзед, ки чӣ гуна ҳалли масъалаҳои марбут ба намуди зоҳирии дастгоҳ, таҳрифи аудио, ҳамоҳангсозии соат ва ғайра.
Пешview Рамзгузор/декодери аудиоии Dante 2CH USB бо POE: Дастури корбар ва хусусиятҳо
Дастури мукаммали корбар барои рамзгузор/декодери аудиоии Dante 2CH USB бо POE. Дар бораи хусусиятҳо, мушаххасот, амалиёт ва истифодаи ... маълумот гиред.amples барои шабакаи касбии аудио.
Пешview Рамзгузори аудиоии аналогии Dante 2CH бо POE | Дастури корбар ва хусусиятҳо
Дастури корбар барои рамзгузори аудиоии аналогии Dante 2CH бо POE, ки хусусиятҳо, мушаххасот, амалиёт ва татбиқи онро муфассал шарҳ медиҳад.amples барои шабакаи касбии аудио.
Пешview DANTE DMIC 3 Dante Microphone Specifications and Features
Detailed specifications and features of the DANTE DMIC 3 Dante microphone, including directivity, frequency response, power supply, and dimensions. Learn about its PoE capabilities and Dante network integration for professional audio applications.
Пешview Dante AVIO Install: 2-Channel Analog Adapters for Pro AV Integrators
Discover the Dante AVIO Install line of 2-channel analog adapters, designed for seamless integration of analog audio equipment into Dante-enabled Pro AV systems. Learn about features like Euroblock terminals, the ClickGrid mounting system, and superior audio performance.