SIMPLEX 4099-9005

Simplex 4099-9005 Addressable Manual Pull Station (Dual Action) User Manual

Модел: 4099-9005

1. Муқаддима

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. Маълумот оид ба бехатарӣ

Дастурҳои муҳими бехатарӣ:

3. Маҳсулот ба охир расидview

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

Пеш view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

Расми 1: Пеш view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. Насбкунӣ

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 Васлкунӣ

4.2 Ноқилҳо

4.3 Танзимоти суроға

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

Тараф view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

Расми 2: Тараф view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. Амалиёт

5.1 Фаъолсозии ҳушдор

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. Дароед: Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. Поён кашед: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 Аз нав танзим кардани истгоҳи интиқол

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. Turn Key: Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. Сарпӯши пӯшида: Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. Нигоҳдорӣ

Regular maintenance ensures the continued reliability of your Simplex 4099-9005 pull station.

7. Баррасии мушкилот

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. Мушаххасоти

ХусусиятМушаххасоти
БрендSIMPLEX
Рақами модел4099-9005
УслубБехатарӣ
Манбаи нерӯДастур
Вазни ашё3.53 унсия (100 Грам)
Навъи ҳушдорAudible (via FACP)
МатериалGlass (referring to break-glass type, though this model is dual-action)
Андозаҳои маҳсулот1 x 3.4 x 5 инч
UPC643485652991
Рақами қисмS4099-9005
Батареяҳо лозимандНе

9. Маълумот дар бораи кафолат

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. Дастгирии муштариён

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.

Ҳуҷҷатҳои марбут - 4099-9005

Пешview Simplex IDNet/MAPNET II Пойгоҳҳои ҳушдордиҳии дастӣ аз сӯхтор - Маълумоти маҳсулот
Маълумоти муфассал дар бораи Simplex 4099 Силсилаи суроғавии истгоҳҳои ҳушдордиҳии сӯхтор, ки бо системаҳои IDNet ва MAPNET II мувофиқанд. Хусусиятҳо, мушаххасот, имконоти васлкунӣ ва интихоби маҳсулот барои моделҳои гуногун, аз ҷумла амали яккаса, амали дукарата (айнаки шиша ва тела) ва имконоти NO GRIP. Бо талаботи ADA мувофиқ аст ва аз ҷониби UL, ULC, FM ва CSFM номбар шудааст.
Пешview Истгоҳҳои дастии суроғашавандаи симплекс: Қисмҳои периферии IDNet/MAPNET II
Истгоҳҳои сигнализатсияи сӯхторхомӯшкунии дастӣ бо суроғаи Simplex-ро омӯзед, хусусиятҳои онҳо, намудҳои амали яккарата/дукарата, имконоти NO GRIP ва мутобиқат бо системаҳои IDNet/MAPNET II-ро муфассал шарҳ диҳед. Маълумоти васлкунӣ ва хусусиятҳоро дар бар мегирад.
Пешview Simplex 2099 Series Single and Double Action Manual Fire Alarm Stations Datasheet
Datasheet for Simplex 2099 Series non-coded, non-addressable manual fire alarm pull stations. Covers features, operation types, application references, product selection, mounting options, and specifications.
Пешview Simplex 4010ES: Системаҳои фармондеҳии автоматии нобудшавӣ
Дастури техникаи Simplex 4010ES тафсилоти модулҳои модулҳои фармондеҳии рехт, системаҳои аз байн рафтани автоматӣ, шеваҳои тозакунӣ ва пешгирикунанда, мушаххасоти авҷ, гомологҳо ва схемаҳои câblage.
Пешview Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
Пешview Simplex 4004 Fire Alarm Control Panel: Installation and Operation Instructions
Comprehensive guide for installing, operating, and programming the Simplex 4004 Fire Alarm Control Panel (FACP), including system overview, requirements, wiring, module descriptions, and troubleshooting.