The LifeSmart LS-946 2TwoPlus Blood Glucose and Ketone Monitoring System is designed for accurate measurement of blood glucose, hematocrit, and ketone levels. This system is suitable for a wide range of users, from infants to adults, due to its broad hematocrit range (0-70%). It features smartphone connectivity for real-time data transfer, viewing, and analysis, enabling users to share their health data with healthcare professionals or family members.

LifeSmart LS-946 2TwoPlus Blood Glucose and Ketone Monitoring System device and features

Расми 1: The LifeSmart LS-946 2TwoPlus meter displaying a reading, alongside key features such as 5-second results, 2+2 Bio-Signal Technology, lifetime warranty, and compatibility with LS-946 test strips. It highlights features like 0-70% HCT range, GDH-FAD enzyme, 3 parameters (Glucose, HCT, Ketone), no coding required, 1.0µL sample size, and a backlight screen.

2. Хусусиятҳои асосӣ

  • Multi-Parameter Measurement: Accurately measures blood glucose, hematocrit (HCT), and ketone levels.
  • Wide Hematocrit Range: Supports a 0-70% hematocrit range, suitable for diverse patient populations.
  • Пайвастшавӣ ба смартфон: Enables real-time data transfer, viewing, and analysis via a dedicated mobile application.
  • Мубодилаи маълумот: Facilitates sharing of health data with doctors, dieticians, or family members.
  • Enzyme Type: Utilizes GDH-FAD for glucose and HBD for ketone measurements.
  • Ketone Warning: Provides alerts for elevated ketone levels.
  • Хурд СampАндоза: Requires only 1.0 µL of blood for testing.
  • Натиҷаҳои зуд: Натиҷаҳоро тақрибан дар давоми 5 сония пешниҳод мекунад.
  • Capacity Memory: Stores up to 1000 memory sets with Date/Time/AC/PC tags.
  • Average Calculations: Provides 7, 14, 21, 28, 60, and 90-day average readings.
  • No Coding: Eliminates the need for manual coding, simplifying the testing process.
  • Backlight Screen: Қобилияти хонданро дар шароити гуногуни равшанӣ таъмин мекунад.

3. Танзимот

  1. Системаро кушоед: Carefully remove all components from the packaging. Verify that the meter, lancing device, lancets, test strips (glucose and ketone), control solution (if included), and user manual are present.
  2. Батареяҳоро насб кунед: Open the battery compartment on the back of the meter and insert the required batteries, ensuring correct polarity. Close the compartment securely.
  3. Таъин кардани сана ва вақт: Power on the meter. Follow the on-screen prompts or refer to the detailed instructions in the full manual to set the current date and time. Accurate date and time settings are crucial for proper record-keeping.
  4. Prepare Lancing Device: Insert a new lancet into the lancing device according to its specific instructions. Adjust the penetration depth setting as needed for your skin type.
  5. Ҷойгиркунии рахи санҷишӣ: The LS-946 system is "No Coding." Insert the appropriate test strip (glucose or ketone) into the meter. The meter will automatically recognize the strip type.
  6. Connect to Smartphone (Optional): Download the LifeSmart mobile application from your device's app store. Follow the app's instructions to pair your LS-946 meter via Bluetooth for data synchronization.

4. Дастурҳои истифодабарӣ

4.1 Санҷиши глюкозаи хун

  1. Дастҳоятонро бо собун ва оби гарм бодиққат бишӯед, сипас онҳоро пурра хушк кунед.
  2. Prepare the lancing device with a fresh lancet.
  3. Insert a new LS-946 Blood Glucose Test Strip into the meter. The meter will turn on automatically and display a blood drop symbol.
  4. Prick the side of your fingertip with the lancing device to obtain a blood sampле.
  5. Gently touch the tip of the test strip to the blood drop. The blood will be drawn into the strip. Do not apply blood to the top of the strip.
  6. The meter will begin counting down (approx. 5 seconds). Your blood glucose result will appear on the display.
  7. Record your result if not using the app, or ensure it syncs with the app.
  8. Dispose of the used lancet and test strip safely in a sharps container.

4.2 Blood Ketone Testing

  1. Follow steps 1-2 from Blood Glucose Testing.
  2. Insert a new LS-946 β-Ketone Test Strip into the meter. The meter will turn on automatically and display a blood drop symbol.
  3. Гирифтани хунample using the lancing device.
  4. Gently touch the tip of the ketone test strip to the blood drop.
  5. The meter will begin counting down. Your blood ketone result will appear on the display.
  6. Record your result or ensure it syncs with the app.
  7. Dispose of the used lancet and test strip safely.

5. Нигоҳдорӣ

  • Cleaning the Meter: Қисми берунии ҳисобкунакро бо матои нарм пок кунед, damp матоъ. Ҳисобкунакро ба об нағӯтонед ва аз воситаҳои тозакунандаи сахт истифода набаред.
  • Нигоҳдорӣ: Store the meter and test strips in a cool, dry place, away from direct sunlight and extreme temperatures. Keep test strips in their original vial with the cap tightly closed.
  • Иваз кардани батарея: Вақте ки дар экран нишондиҳандаи камии батарея пайдо мешавад, батареяҳоро иваз кунед.
  • Test Strip Expiration: Always check the expiration date on the test strip vial. Do not use expired test strips as they may yield inaccurate results.
  • Назорати сифат: Perform control solution tests regularly as recommended in the full user manual to ensure the meter and strips are working correctly.

6. Баррасии мушкилот

МушкилотСабаби эҳтимолӣҲалли
Метр фурӯзон намешавад.Батареяҳои мурда ё нодуруст гузошташуда.Самти батареяро тафтиш кунед ё батареяҳоро иваз кунед.
Хониши нодуруст.Expired test strips, improper sample application, or meter malfunction.Check strip expiration, re-test with new strip and proper technique, perform control solution test.
Паёми хато дар экран.Refer to the full user manual for specific error codes.Consult the manual's error code section or contact customer support.
Бо смартфон пайваст кардан мумкин нест.Bluetooth off, app not installed, or pairing issue.Ensure Bluetooth is on, reinstall app, restart both devices, try pairing again.

7. Мушаххасоти

Модели маҳсулот:LS-946 (SI-10006777)
Андозаҳо (L x W x H):1 x 7 x 1 cm (Meter) / 10 x 70 x 10 mm (Packaging)
Вазн:1 грамм
Параметрҳои ченшуда:Blood Glucose, Hematocrit (HCT), β-Ketone
Диапазони гематокрит:0% - 70%
SampАндоза:1.0 мкл
Вақти санҷиш:тахминан. 5 сония
Хотира:1000 test results with Date/Time/AC/PC
Пайвастшавӣ:Bluetooth (for smartphone app)
Enzyme Type:GDH-FAD (Glucose), HBD (Ketone)
Рамзгузорӣ:No Coding Required

8. Кафолат ва дастгирӣ

The LifeSmart LS-946 2TwoPlus Blood Glucose and Ketone Monitoring System comes with a Кафолати якумрӣ. To activate your warranty and for detailed terms and conditions, please visit the official LifeSmart webсайт дар mylifesmart.net.au ва маҳсулоти худро ба қайд гиред.

For technical support, troubleshooting assistance, or inquiries regarding your device, please contact LifeSmart customer service through the contact information provided on their official webсайт ё дар дохили бастаи маҳсулот.

Ҳуҷҷатҳои марбут - LS-946

Пешview Дастури истифодабарандаи системаи мониторинги глюкозаи хун ва бета-кетонҳои LifeSmart LS-946
Ин дастур маълумоти муҳимро барои истифодаи дурусти Системаи мониторинги глюкозаи хун ва бета-кетонҳои LifeSmart LS-946 пешниҳод мекунад. Дар бораи хусусиятҳо, насб, тартиби санҷиш, нигоҳдорӣ ва ҳалли мушкилот маълумот гиред.
Пешview LifeSmart LS946N Blood Glucose & Ketone Monitor Quick Start Guide
Concise quick start guide for the LifeSmart LS946N Blood Glucose plus Beta Ketone Monitoring System, covering app setup, device configuration, and pairing.
Пешview Дастури корбари LifeSmart MINS Curtain Motor Controller
Дастури корбар барои назорати мотори LifeSmart MINS Curtain, муфассал дастурҳои маҳсулот, мушаххасот, таърифҳои интерфейс, насб, мундариҷаи баста, кафолат ва нуқтаҳои таваҷҷӯҳ. Пардаҳои анъанавиро ба идоракунии оқилона такмил диҳед.
Пешview Дастури корбарии Cololight PLUS V1.0: Танзимот, хусусиятҳо ва мушаххасот
Дастури мукаммали корбар барои нури муҳити зист LifeSmart Cololight PLUS. Муаррифии маҳсулот, насб, хусусиятҳо, мушаххасот, назорати барнома, кафолат ва эъломияҳоро дар бар мегирад.
Пешview LifeSmart LS-320 Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the LifeSmart LS-320 Dual Mode Digital Infrared Thermometer, covering features, operation, safety precautions, troubleshooting, and specifications.
Пешview Дастури истифодабарандаи системаи гармидиҳии минтақавии инфрасурхи LIFESMART LS-4P1500-HOM
Дастури истифодабаранда барои системаи гармидиҳии инфрасурхи минтақавии LIFESMART LS-4P1500-HOM. Дастурҳои муҳими бехатарӣ, тартиби кор, дастурҳои нигоҳдорӣ, маслиҳатҳои ҳалли мушкилот ва маълумоти кафолатро барои истифодаи беҳтарин дар бар мегирад.