This manual provides essential information for the safe and efficient operation of your Einhell GC-DW 1045 N Deep Well Pump. Please read these instructions carefully before initial use and keep them for future reference. This robust base pump is designed for pumping clear and service water for garden and household use, featuring a multi-stage impeller for constant pressure and a powerful motor.

Image: The Einhell GC-DW 1045 N Deep Well Pump with its included drain rope.
2. Дастурамал оид ба бехатарӣ
Барои пешгирӣ аз ҷароҳат ва вайроншавии насос, ҳамеша чораҳои бехатарии зеринро риоя кунед:
- Ensure the power supply matches the pump's specifications (230 V).
- Do not operate the pump in explosive atmospheres or with flammable liquids.
- Never pull the pump by its power cable. Use the provided drain rope for lowering and retrieving.
- Protect the pump from frost. Disconnect and drain it during winter months if not in continuous use.
- Ensure the well or bore hole has sufficient operating space (minimum 99 x 99 mm) to prevent the pump from getting stuck.
- The pump is equipped with thermal overload protection. If it overheats, it will shut off automatically. Allow it to cool down before restarting.
3. Танзимот
- Кушодани: Carefully remove the pump and all accessories from the packaging. Check for any transport damage.
- Connecting the Pressure Hose: Attach a suitable pressure hose to the pump's discharge connection. Ensure a tight, leak-free seal.

Image: Close-up of the pump's pressure connection point.
- Attaching the Drain Rope: Securely fasten the provided drain rope to the designated eyelets on the pump. This rope is crucial for safe lowering and retrieval.

Image: The deep well pump with the drain rope attached, ready for deployment.
- Lowering the Pump: Carefully lower the pump into the well using the drain rope. Ensure the pump hangs freely and does not touch the bottom or sides of the well. Maintain the minimum operating space of 99 x 99 mm.

Image: Diagram illustrating the required minimum operating space of 99 x 99 mm for the pump in a well.

Image: Diagram showing the deep well pump submerged in a water source.
- Пайвастагии барқ: Connect the pump to a properly grounded power outlet (230 V). Ensure the connection is protected from moisture.
4. Амалиёт
Once properly installed, operating the Einhell GC-DW 1045 N is straightforward:
- Оғози ибтидоӣ: After ensuring all connections are secure and the pump is fully submerged, switch on the power. The pump will begin to draw water. It may take a few moments for water to flow consistently as air is purged from the system.
- Фаъолияти доимӣ: Мулти-сtage impeller ensures constant pressure and efficient water delivery. The pump is designed for continuous operation within its specified limits.
- Мониторинг: Periodically check the water flow and pump sound. Any unusual noises or reduced flow may indicate an issue.

Image: A person preparing to install the deep well pump into a well opening.

Image: Diagram showing the multi-stage impeller system inside the pump, designed for consistent pressure.
5. Нигоҳдорӣ
Regular maintenance ensures the longevity and optimal performance of your deep well pump:
- Cleaning the Dirt Sieve: The pump is equipped with a dirt sieve. If water flow decreases significantly, the sieve may be clogged. Retrieve the pump and clean the sieve as needed.

Image: Close-up of the dirt sieve at the bottom of the pump.
- Санҷиши пайвастшавӣ: Periodically inspect all hose and electrical connections for wear, damage, or leaks.
- Зимистонгузаронӣ: If the pump will not be used during freezing temperatures, it must be removed from the well, thoroughly drained, and stored in a frost-free environment.
- Мӯҳри механикӣ: The high-quality mechanical seal is designed for long service life and generally requires no maintenance.
6. Баррасии мушкилот
Пеш аз тамос бо хадамоти муштариён, роҳҳои ҳалли зеринро барои мушкилоти умумӣ санҷед:
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Насос оғоз намекунад. | No power supply; Thermal overload protection activated. | Check power connection and circuit breaker; Allow pump to cool down for 30 minutes. |
| Ҷараёни об кам ё тамоман нест. | Clogged dirt sieve; Air in the system; Hose kinked or blocked; Water level too low. | Clean dirt sieve; Ensure pump is fully submerged and primed; Check hose for obstructions; Verify sufficient water in well. |
| Pump motor hums but does not pump. | Impeller blocked; Air lock. | Disconnect power, retrieve pump and check for obstructions around impeller; Ensure pump is properly submerged and primed. |
If problems persist after attempting these solutions, please contact qualified service personnel.
7. Мушаххасоти
| Хусусият | Арзиш |
|---|---|
| Рақами модел | 4170955 |
| Қувва | 1000 ватт |
| Ҷилдиtage | 230 вольт |
| Макс. Меъёри ҷараён | 6500 литр дар як соат |
| Max. Head Height | 45 метр |
| Диаметри насос | 99 mm (implied from operating space) |
| Материал | Пулоди Зангнамезадагӣ |
| Вазни ашё | 7.7 килограмм |
| Андозаҳо (L x W x H) | 73 х 14 х 22 см |
| Ба таҳвил дохил карда шудааст | Deep well pump; Drain rope |

Image: Icon indicating a flow rate of 6500 liters per hour.

Image: Icon indicating a maximum head height of 45 meters.
8. Кафолат ва дастгирӣ
Einhell offers extended warranty services for its products:
- Кафолати тамдидшуда: Einhell extends the warranty period for all Einhell Power X-Change batteries and Einhell devices to 3 years.
- Фаъолсозӣ: To activate the extended warranty, Einhell products must be registered on the official Einhell webсайт дар давоми 30 рӯзи харид.

Image: Einhell 3-year warranty logo, indicating extended warranty upon online registration.
For further support, technical assistance, or to register your product, please visit the official Einhell website or contact their customer service department. Keep your purchase receipt and model number handy when seeking support.
Шумо метавонед маълумоти бештар ва тафсилоти тамосро дар сайт пайдо кунед Einhell Store Page.