1. Муқаддима
This manual provides essential information for the proper installation, operation, and maintenance of the AKO D-14323 230V Universal Digital Temperature Controller. Designed for industrial and commercial refrigeration applications, this controller offers precise temperature management and adjustable defrost cycles. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
2. Маълумот оид ба бехатарӣ
Барои пешгирии осеби шахсӣ ё осеб дидани дастгоҳ ҳамеша чораҳои бехатарии зеринро риоя кунед:
- Насбкунӣ ва нигоҳдорӣ бояд танҳо аз ҷониби кормандони соҳибихтисос анҷом дода шаванд.
- Disconnect power to the unit before performing any wiring or maintenance.
- Таъмини таъминоти барқ voltage matches the controller's specifications (230V).
- Protect the device from water, moisture, and extreme temperatures.
- Do not open the controller housing unless specifically instructed.
3. Маҳсулот ба охир расидview
The AKO D-14323 is a versatile digital temperature controller equipped with a clear digital display and intuitive controls. It is suitable for a wide range of refrigeration and freezer units.
Хусусиятҳои асосӣ:
- Digital thermostat for industrial and commercial freezers.
- Temperature range from -50.0 °C to +99.9 °C (-58°F to +210.2°F).
- Three relays for compressor, fan, and auxiliary functions.
- Two temperature sensors included.
- Panel mounting design.
- Programmable defrost cycles.
- Fahrenheit and Celsius readings.
- Programmable digital inputs for door switch, alarm, remote defrost, energy saving, or continuous cycle.
Controller Front Panel:

Тасвири 3.1: Пеш view of the AKO D-14323 controller, showing the digital display and control buttons. The display shows temperature readings, and buttons include ESC, SET, Power, and up/down arrows (often used for defrost and parameter adjustment).
The front panel features a digital display for temperature readings and status indicators. Control buttons allow for setting parameters, initiating defrost cycles, and navigating menus.
4. Насб ва насб
Proper installation is crucial for the controller's performance and longevity.
4.1 Монтажи панел
The AKO D-14323 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals.
4.2 Пайвастҳои барқӣ
Refer to the wiring diagram on the back of the unit for correct electrical connections. All wiring must comply with local electrical codes.

Тасвири 4.1: Бозгашт view of the AKO D-14323 controller, displaying the wiring diagram and product specifications. This diagram illustrates connections for power (230V), sensors (S1, S2), compressor (COOL), fan, and auxiliary outputs, along with digital inputs (D1, D2).
Wiring Key Points:
- Таъмини нерӯ: Connect 230V AC to the designated terminals.
- Сенсорҳо: Connect the two temperature sensors (S1, S2) to their respective terminals.
- Натиҷаҳои реле: Connect the compressor, fan, and auxiliary loads to their corresponding relay terminals. The diagram specifies maximum current ratings for each output (e.g., COOL: 12(9)A 250V~, FAN: 5(4)A 250V~, AUX: 8(4)A 250V~).
- Вурудоти рақамӣ: Utilize terminals for programmable digital inputs such as door switches or external alarms.
4.3 Фаъолсозии ибтидоӣ
After wiring, apply power to the controller. The display should illuminate, showing the current temperature or an initial setup prompt.
5. Дастурҳои истифодабарӣ
The AKO D-14323 offers various programmable parameters to suit different refrigeration needs.
5.1 Амалиёти асосӣ
- Намоиши ҳарорат: The main display shows the current temperature measured by the primary sensor.
- Тугмаи SET: -ро пахш кунед view or modify the setpoint temperature. Hold to enter parameter programming mode.
- Тугмаи ESC: Used to exit menus or cancel changes.
- Тирҳои боло/поён: Used to adjust values in programming mode or manually initiate defrost (if configured).
- Тугмаи барқ: Turns the unit on/off or acts as a reset in some configurations.
5.2 Setting the Temperature Setpoint
- -ро пахш кунед САТ button briefly. The current setpoint will flash.
- -ро истифода баред Up or Поён тугмаҳои тирча барои танзими ҳарорати дилхоҳ.
- пахш кунед САТ again to confirm and save the new setpoint, or ФАРОР бе захира кардан баромадан.
5.3 Advanced Parameter Programming
To access advanced parameters (e.g., defrost cycles, differential, auxiliary relay functions), hold the САТ button for several seconds until the first parameter code appears. Navigate using the arrow buttons and press САТ to enter/confirm values. Refer to the detailed programming guide (usually provided separately or available from AKO) for a complete list of parameters and their functions.
5.4 Defrost Cycle Management
The controller supports various defrost methods, including controlling the compressor, resistance heaters, or fans. Defrost parameters can be adjusted to optimize performance based on the application. An optional probe allows defrosting by temperature.
6. Нигоҳдорӣ
Regular maintenance ensures optimal performance and extends the lifespan of your temperature controller.
- Тозакунӣ: Periodically clean the front panel with a soft, damp матоъ. Тозакунанда ё ҳалкунандаҳои абразивиро истифода набаред.
- Санҷишҳо: Regularly check wiring connections for tightness and signs of wear or corrosion.
- Санҷиши сенсор: Ensure temperature sensors are securely in place and free from damage.
For any internal maintenance or repairs, contact a qualified technician.
7. Баррасии мушкилот
If you encounter issues with your AKO D-14323 controller, refer to the following common problems and solutions:
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Намоиш холӣ аст | Не таъминоти барқ; ноқилҳои нодуруст | Check power connections and ensure 230V supply. Verify wiring according to the diagram. |
| Хониши нодурусти ҳарорат | Faulty sensor; sensor not properly connected or placed | Check sensor connections. Replace sensor if damaged. Ensure sensor is correctly positioned in the controlled environment. |
| Compressor/Fan not operating | Setpoint issue; relay fault; wiring error; parameter misconfiguration | Verify setpoint and differential settings. Check wiring to the compressor/fan. Review advanced parameters for correct configuration. |
| Барф кардани яхкунӣ оғоз намешавад | Defrost parameters incorrect; manual defrost not triggered | Check defrost cycle settings (interval, duration, temperature). Attempt manual defrost if configured. |
If the problem persists after attempting these solutions, contact AKO technical support or a qualified service technician.
8. Мушаххасоти
Detailed technical specifications for the AKO D-14323 controller:
- Модели: AKO D-14323
- Ҷилдиtage: 230 вольт
- Диапазони ҳарорат: -50.0 °C to +99.9 °C (-58°F to +210.2°F)
- Реле: 3 (Compressor, Fan, Auxiliary)
- Сенсорҳо: 2 temperature sensors included
- Монтаж: Монтажи панел
- Мавод: Пластмасса
- Вазни ашё: 0.01 унсия (тақрибан)
- Услуби намоиш: Рақамӣ
- Хусусиятҳои махсус: Барномашаванда
- Истифода: Тиҷоратӣ / истиқоматӣ
- Сертификатсияҳо: ETL, CE, IP65, GAMA
- Истеҳсолкунанда: AKOCONTROL
9. Кафолат ва дастгирӣ
For warranty information and technical support, please contact AKO directly or refer to their official webсайт. Квитансияи хариди худро барои даъвоҳои кафолат нигоҳ доред.
Истеҳсолкунанда: AKOCONTROL
Webсайт: www.ako.com