1. Муқаддима
The YA-MAN RF Core EX HRF-18T is a home-use beauty device designed for body, face, and bust care. It integrates three popular beauty salon technologies: Cavitation, Radio Frequency (RF), and Electrical Muscle Stimulation (EMS). This device is waterproof (IPX7 equivalent), allowing for use during bath time.
This manual provides essential information for the safe and effective use of your device. Please read it thoroughly before first use and keep it for future reference.
2. Чорабиниҳои бехатарӣ
Failure to follow these safety instructions may result in injury or device malfunction.
2.1 Do Not Use If You Have Any of the Following Conditions:
- Persons using medical electrical equipment (e.g., implanted pacemakers, life support systems, wearable medical devices).
- Persons with heart disease, disorders, or suspected conditions.
- Persons unable to express their will.
- Persons unable to perceive temperature or stimulation.
- Persons from early pregnancy until immediately after childbirth.
- Persons with autoimmune diseases.
- Persons with uterine diseases such as endometriosis or uterine fibroids.
2.2 Consult a Doctor Before Use If You Have Any of the Following Conditions:
- Acute diseases.
- Бемориҳои сироятӣ.
- Омосҳои ашаддӣ.
- Febrile diseases.
- High blood pressure or blood disorders.
- Fever.
- Sensory impairment due to severe peripheral circulatory dysfunction, such as diabetes.
- Neurological disorders.
- Skin diseases or atopic dermatitis.
- Undergoing medical treatment and taking medication.
- Allergic constitution, contact dermatitis, or other pre-existing skin conditions, or those concerned about their skin during use.
2.3 Do Not Use On Areas Other Than Specified or On the Following Areas:
- Fractured areas.
- Areas with metal implants due to surgical procedures (plastic, orthopedic, cosmetic).
- Areas with internal bleeding, swelling, scabs, etc., after cosmetic medical procedures. (For such areas, refrain from use for 2 weeks after the procedure and consult a doctor before resuming use. Examples of procedures: hyaluronic acid injection, silicone injection, Botox, thread lift, double eyelid surgery, HIFU, etc.)
If you feel unwell or notice any skin abnormalities during use, stop immediately and consult a doctor if the condition does not improve.
3. Маҳсулот ба охир расидview ва Хусусиятҳо
The YA-MAN RF Core EX HRF-18T combines three advanced technologies for comprehensive beauty care:
- RF (Radio Frequency): This high-frequency technology warms the skin from deep within by reacting to moisture, commonly used in professional beauty salons.
- Кавитация: Utilizes powerful 330kHz ultrasonic waves to vibrate the skin, targeting specific areas.
- EMS (Ҳавасмандгардонии мушакҳои барқӣ): Delivers electrical impulses to stimulate muscles. This model features a "Double Wave EMS" combining medium and low frequencies.
This device offers total care for the face, body, and bust. It is waterproof (IPX7 equivalent), allowing for safe use during bath time to enhance the warming effect.

Image: The YA-MAN RF Core EX HRF-18T device, showcasing its ergonomic design and control panel.

Image: Diagram illustrating the three core technologies of the device: RF for warming, Cavitation for targeted vibration, and EMS for muscle stimulation.
4. Танзимот
4.1 Кушодани қуттӣ ва санҷиши ибтидоӣ
Carefully remove the device and all accessories from the packaging. Check for any visible damage. The package should contain:
- YA-MAN RF Core EX HRF-18T main unit
- Адаптери AC
- Дастури таълимӣ (ин ҳуҷҷат)
4.2 Пур кардани дастгоҳ
- Адаптери AC-ро ба порти пуркунандаи дастгоҳ пайваст кунед.
- Plug the AC adapter into a power outlet (100-240V).
- Нишондиҳандаи барқгиранда фурӯзон мешавад. Барои пур кардани барқ тақрибан 3 соат вақт мегирад.
- Once fully charged, the indicator light will change or turn off (refer to the device's specific indicator behavior).
Шарҳ: Ensure the device is fully charged before its first use for optimal performance. Do not operate the device while it is charging.

Image: The YA-MAN RF Core EX HRF-18T device placed on its charging base, indicating the charging process.
5. Дастурҳои истифодабарӣ
Before use, ensure your skin is moisturized with gel or lotion. The device can be used in the bath, but applying a conductive gel is recommended for smoother gliding and better results.
5.1 Фаъолсозӣ/хомӯшкунӣ ва интихоби режим
- Барои фаъол кардани дастгоҳ тугмаи барқро пахш карда нигоҳ доред.
- Press the "MODE" button to cycle through available modes (e.g., RF, Cavitation, EMS).
- Use the level adjustment buttons (usually "+" and "-") to select the desired intensity for RF (3 levels) and EMS (6 levels).
- Барои хомӯш кардани дастгоҳ, тугмаи барқро пахш карда нигоҳ доред.

Image: Close-up of the device's control panel, showing buttons for mode selection and intensity levels for RF (3 levels) and EMS (6 levels).
5.2 Usage Areas and Techniques
The device is designed for use on various body parts, face, and bust. A typical session duration is approximately 10 minutes per area.
For Body:
- Яроқ: Glide the device upwards from the elbow to the shoulder.
- Шикам: Move the device in circular motions or upwards from the lower abdomen.
- Хип: Glide the device upwards from the thighs towards the hips.
- Thighs: Move the device upwards from the knee to the hip.
- Calves: Glide the device upwards from the ankle to the knee.
For Face:
- рухсораҳо: Gently glide the device upwards from the jawline towards the temples.
- Пешонӣ: Move the device upwards from the eyebrows to the hairline.
- Jawline: Glide along the jawline from the chin towards the ears.
For Bust (EX Model Exclusive):
The Bust Mode is specifically designed to target muscles around the bust area. This mode combines RF and EMS for a dual approach.
- Қадами 1: Before treatment, stretch your back to refresh the area.
- Қадами 2: Gently glide the device from under the bust towards the armpit, feeling the RF warmth and EMS stimulation.
- Қадами 3: Move the device upwards from the back towards the bust, lifting the muscles.

Image: Illustration detailing the exclusive Bust Mode feature of the EX model, showing the target muscles (pectoralis major and minor) and the combined RF and EMS approach.

Image: Visual guide demonstrating recommended usage techniques for various body parts (arms, abdomen, hips, thighs, calves), face, and a three-step process for the Bust Mode.
Муҳим: Always apply a conductive gel or lotion to the skin before using the device to ensure smooth gliding and effective treatment. Avoid using the device on dry skin.
6. Нигоҳдорӣ
Нигоҳубини дуруст умри дароз ва гигиении дастгоҳи шуморо таъмин мекунад.
6.1 Тоза кардани дастгоҳ
- After each use, wipe the device clean with a soft, damp матоъ.
- For stubborn residue, use a mild soap solution on the cloth, then wipe again with a clean, damp матоъ.
- Ensure no water enters the charging port or other openings.
- Dry the device thoroughly with a soft, dry cloth before storing.
Шарҳ: The device is waterproof, but it is important to dry it completely after use, especially if used in the bath, to prevent water accumulation in crevices and ensure proper function.
6.2 Нигоҳдорӣ
Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it out of reach of children.
7. Баррасии мушкилот
If you encounter any issues with your YA-MAN RF Core EX HRF-18T, please refer to the following common problems and solutions:
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Дастгоҳ фурӯзон намешавад. | Батарея тамом шудааст. | Дастгоҳро тақрибан 3 соат пур кунед. |
| Ҳангоми истифода ягон эҳсоси заиф ё нотавонӣ вуҷуд надорад. | Insufficient conductive gel/lotion. Intensity level is too low. Device not making full contact with skin. | Apply more gel/lotion. Баланд бардоштани сатҳи шиддат. Ensure the device head is in full contact with the skin. |
| Пӯст худро нороҳат ҳис мекунад ё хашмгин мешавад. | Intensity level is too high. Пӯст хеле хушк аст. Аксуламали аллергӣ. | Сатҳи шиддатро кам кунед. Apply more gel/lotion. Stop use immediately and consult a doctor if irritation persists. |
| Charging issues (e.g., not charging, intermittent charging). | Charging port or adapter connection issues. Corroded charging terminals. | Ensure the AC adapter is securely connected to both the device and the power outlet. Clean charging terminals if visible corrosion. If issues persist, contact customer support. |
If the problem persists after trying these solutions, please contact YA-MAN customer support.
8. Мушаххасоти
| Хусусият | Тафсилот |
|---|---|
| Рақами модел | HRF-18T |
| Бренд | Я-МАН |
| Вуруди ҷилдиtage | 100-240В |
| Андозаҳо (тақрибан) | 83 × 116 × 97 мм |
| Main Unit Weight (approx.) | 307г |
| Кишвари истеҳсолкунанда | Япония |
| Лавозимот | Адаптери AC |
| Вақти пуркунии барқ (тақрибан) | 3 соат |
| Вақти корӣ (тақрибан) | дақиқа 30 |
| Сатҳи обногузар | Муодили IPX7 |
| Материалхо | ABS resin, PET resin, Polycarbonate |
| Навъи батарея | Литий-ион (дарун) |
9. Кафолат ва дастгирӣ
For warranty information and customer support, please refer to the warranty card included with your product or visit the official YA-MAN webсайт. Барои даъвоҳои кафолат далели хариди худро нигоҳ доред.
If you experience any issues not covered in the troubleshooting section, or require further assistance, please contact YA-MAN customer service.
YA-MAN Official Webсайт: www.ya-man.com