1. Муқаддима
This manual provides comprehensive instructions for the proper setup, operation, and maintenance of your VWR 10500-584 Traceable Refrigerator/Freezer Ultra Thermometer. This device is designed to accurately monitor temperatures in refrigerators and freezers, displaying current, minimum, and maximum readings simultaneously. It is engineered to meet stringent requirements for critical temperature monitoring, including CDC guidelines for vaccine storage.
2. Хусусиятҳои маҳсулот
- Намоиши сегона: Ҳамзамон ҳарорати ҷорӣ, ҳадди ақал ва ҳадди аксарро нишон медиҳад.
- Диапазони васеъи ҳарорат: Андозаҳо аз -50 ° C то 70 ° C (-58 ° F то 158 ° F).
- Қарори баланд: 0.1° resolution for precise readings.
- Ultra Accuracy: ±0.5°C accuracy between -30°C and 50°C; otherwise ±1°C.
- CDC Compliance: Designed to meet current CDC requirements for vaccine storage and monitoring.
- Интихоби санҷиш: Features a switch for selecting between two probes (if applicable, based on image).
- Memory Clear Function: Button to reset minimum and maximum temperature records.
3. Танзимот
Follow these steps to prepare your thermometer for use:
- Насби батарея: Open the battery compartment (typically on the back) and insert the required batteries, observing correct polarity.
- Ҷойгиркунии зонд: Connect the temperature probe(s) to the designated ports. Place the probe(s) in the desired monitoring location within the refrigerator or freezer. Ensure the probe cable is not pinched or damaged by the door seal.
- Фаъолсозии ибтидоӣ: The device should power on automatically once batteries are installed. Verify the display shows temperature readings.
- Интихоби воҳид: If applicable, select the desired temperature unit (°C or °F) using the appropriate button (often the 'MODE' button or a dedicated switch).

Расми 1: VWR 10500-584 Traceable Refrigerator/Freezer Ultra Thermometer. The image displays the thermometer unit with its digital screen showing temperature readings, and a connected probe immersed in a small bottle, likely simulating a buffered solution for stable temperature measurement.
4. Дастурҳои истифодабарӣ
Understanding the display and controls:
- Ҳарорати ҷорӣ: The largest number on the display indicates the real-time temperature reading from the selected probe.
- Minimum (MIN) Temperature: Shows the lowest temperature recorded since the last memory clear.
- Maximum (MAX) Temperature: Shows the highest temperature recorded since the last memory clear.
- MEMORY CLEAR Button: Press this button to reset the recorded minimum and maximum temperatures. The current temperature will then become the initial MIN and MAX values until new extremes are reached.
- Тугмаи MODE: This button typically cycles through display modes or switches between Celsius and Fahrenheit units. Refer to the specific device markings for its exact function.
- PROBE Switch (1/2): If your model has two probes, use this switch to select which probe's readings are displayed as the current temperature. The MIN/MAX values will correspond to the currently selected probe.
5. Нигоҳдорӣ
- Тозакунӣ: Wipe the thermometer unit and probes with a damp cloth. Do not immerse the main unit in water. Avoid using abrasive cleaners or solvents.
- Иваз кардани батарея: When the display becomes dim or the low battery indicator appears, replace the batteries promptly. Use the specified battery type.
- Нигоҳубини санҷиш: Handle probes carefully. Avoid bending or kinking the probe cables excessively. Ensure probe connections are secure.
- Нигоҳдорӣ: When not in use for extended periods, remove batteries and store the thermometer in a cool, dry place.
6. Баррасии мушкилот
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Намоиш ё намоиши хира | Батареяҳои мурда ё кам; нодуруст насб кардани батарея. | Батареяҳоро бо батареяҳои нав иваз кунед, ки полярии дурустро таъмин кунед. |
| Хонишҳои нодурусти ҳарорат | Probe not properly connected; damaged probe; external interference. | Check probe connection. Inspect probe for damage. Ensure probe is correctly positioned. |
| MIN/MAX values not resetting | 'MEMORY CLEAR' button not pressed firmly or device malfunction. | Press the 'MEMORY CLEAR' button firmly. If issue persists, contact support. |
7. Мушаххасоти
- Рақами модел: 10500-584
- Диапазони ҳарорат: -50°C то 70°C (-58°F то 158°F)
- Қарор: 0.1°
- Дақиқӣ: ±0.5°C between -30°C and 50°C; otherwise ±1°C
- Андозаҳои баста: 12.7 х 10.16 х 5.08 см
- Вазн: 1.36 кг
- Истеҳсолкунанда: VWR International
8. Кафолат ва дастгирӣ
For warranty information or technical support regarding your VWR 10500-584 Traceable Refrigerator/Freezer Ultra Thermometer, please contact VWR International directly through their official webсайт ё каналҳои хидматрасонии муштариён. Квитансияи хариди худро ҳамчун далели харид нигоҳ доред.