Муқаддима
This document serves as the official instruction manual for the Tektronix T912 10 MHz Storage Oscilloscope. It provides comprehensive information regarding the setup, operation, maintenance, and troubleshooting of the instrument. Users are advised to read this manual thoroughly to ensure safe and efficient use of the Tektronix T912 oscilloscope.
Маълумот оид ба бехатарӣ
Always observe the following safety precautions when operating the Tektronix T912 oscilloscope:
- Манбаи нерӯ: Асбобро танҳо ба манбаи барқ бо ҳаҷми муайяншуда пайваст кунедtage and frequency. Ensure proper grounding.
- Вентилятсия: Do not block ventilation openings. Adequate airflow is essential to prevent overheating.
- Шароити экологӣ: Operate the oscilloscope in a dry environment, away from moisture, dust, and extreme temperatures.
- Probes and Cables: Use only probes and cables designed for the instrument and rated for the voltages being measured.
- Хизматрасонӣ: Refer all servicing to qualified service personnel. Do not attempt to open or repair the instrument yourself.
- Ҷилди баландtage: Аз ҳаҷми баланд огоҳ бошедtage hazards. Always disconnect power before making or changing connections, especially when dealing with high voltagсхемаҳои e.
Маҳсулот ба охир расидview: The Instruction Manual
Ин бахш бартарӣ медиҳадview of the physical instruction manual itself, which guides users through the operation of the Tektronix T912 10 MHz Storage Oscilloscope.

Figure 1: Front Cover of the Instruction Manual. This image displays the blue front cover of the Tektronix T912 10 MHz Storage Oscilloscope Instruction Manual. The Tektronix logo is prominently featured at the top, with "T912 10 MHz STORAGE OSCILLOSCOPE WITH OPTIONS" and "INSTRUCTION MANUAL" printed below. The manual is spiral-bound on the left side.

Figure 2: Inside Cover Page of the Instruction Manual. This image shows the inside cover page of the manual. It features the Tektronix logo with "COMMITTED TO EXCELLENCE" below it. Text prompts the user to "PLEASE CHECK FOR CHANGE INFORMATION AT THE REAR OF THIS MANUAL." Details about the T912 model, storage oscilloscope, and instruction manual are visible, along with Tektronix Inc. contact information, product group, serial number, and printing dates (First Printing JUL 1975, Revised JUL 1982).

Figure 3: Back Cover of the Instruction Manual. This image displays the plain blue back cover of the spiral-bound instruction manual. It matches the front cover's color and texture, showing the spiral binding along the left edge.
Ташкил кардан
Proper setup is crucial for accurate measurements and safe operation. Follow these general steps:
- Кушодани: Carefully remove the oscilloscope and all accessories from its packaging. Inspect for any signs of shipping damage.
- Ҷойгиршавӣ: Place the oscilloscope on a stable, level surface with adequate ventilation space around it.
- Пайвасти барқ: Connect the power cord to the instrument and then to a grounded AC power outlet matching the specified voltage.
- Пайвастшавии зонд: Connect the desired probes to the input channels. Ensure probes are properly compensated before use.
- Фаъолсозии ибтидоӣ: Turn on the oscilloscope and allow it to warm up for a few minutes as per the specific instructions in the full manual.
Дастурҳои амалиётӣ
The Tektronix T912 is a 10 MHz storage oscilloscope designed for capturing and displaying waveforms. Basic operation involves:
- Фаъол / Хомӯш: Use the main power switch to turn the unit on or off.
- Назорати амудӣ: Adjust the VOLTS/DIV knob for each channel to set the vertical sensitivity. Use the POSITION knob to move the waveform vertically.
- Назорати уфуқӣ: Adjust the SEC/DIV knob to set the time base. Use the POSITION knob to move the waveform horizontally.
- Интиқол: Set the TRIGGER LEVEL and SOURCE to stabilize the waveform display. The T912, being a storage oscilloscope, allows for capturing single-shot events.
- Функсияи нигоҳдорӣ: Utilize the storage controls to capture and hold transient or non-repetitive waveforms on the screen for detailed analysis. Refer to the full manual for specific storage mode operations.
- Focus and Intensity: Adjust these controls for a clear and bright display.
Нигоҳдорӣ
Regular maintenance ensures the longevity and performance of your oscilloscope:
- Тозакунӣ: Пеш аз тоза кардан, барқро ҷудо кунед. нармро истифода баред, гamp cloth with a mild detergent to clean the exterior. Avoid abrasive cleaners or solvents.
- Нигоҳдорӣ: When not in use, store the oscilloscope in a clean, dry environment, protected from dust and extreme temperatures.
- Калибрченкунӣ: Periodically, the oscilloscope may require calibration to maintain accuracy. Refer to the detailed calibration procedures in the complete service manual or contact qualified service personnel.
- Нигоҳубини санҷиш: Inspect probes regularly for damage. Keep probe tips clean.
Мушкилкушо
If you encounter issues with your Tektronix T912, consider the following common troubleshooting steps:
- Намоиши:
- Check power connection and fuse.
- Ensure intensity and focus controls are not set to minimum.
- Verify that the oscilloscope is powered on.
- Шакли мавҷи ноустувор:
- Adjust the trigger level and source settings.
- Check probe connections and compensation.
- Ensure the input signal is within the oscilloscope's measurement range.
- Ягон сигнал нишон дода нашудааст:
- Verify the input signal is present at the probe tip.
- Check channel selection and vertical position.
- Ensure the probe is correctly connected to the circuit under test.
- Distorted Waveform:
- Check probe compensation.
- Ensure the signal amplitude does not exceed the vertical range.
- Verify the signal frequency is within the oscilloscope's bandwidth.
For more detailed troubleshooting, consult the complete instruction manual or contact Tektronix support.
Мушаххасоти
The following specifications apply to the Tektronix T912 10 MHz Storage Oscilloscope:
| Хусусият | Тафсилот |
|---|---|
| Истеҳсолкунанда | Tektronix |
| Модели | T912 |
| Маҷрои маҷрои | 10 МГц |
| Навъи | Осциллографи нигоҳдорӣ |
| Дастгоҳҳои мувофиқ | Personal computer (as per product listing) |
| Интерфейси корти графикӣ | Integrated (as per product listing) |
Note: Some specifications like "Compatible Devices" and "Graphics Card Interface" are derived from the product listing and may refer to specific configurations or accessories. For detailed technical specifications, refer to the original Tektronix T912 service manual.
Кафолат ва дастгирӣ
For warranty information, please refer to the documentation provided at the time of purchase or contact the seller (ROA) or the manufacturer (Tektronix) directly. Support resources, including technical assistance and service options, can typically be found on the official Tektronix webсайт ё бо тамос бо шӯъбаи хизматрасонии муштариён.
Ширкати Tektronix, Inc.
Почтаи почта 500
Бивертон, Орегон 97077
First Printing JUL 1975
Revised JUL 1982