Idec RJ2S-CL-D12

RJ2S-CL-D12 Electromechanical Relay User Manual

Model: RJ2S-CL-D12 | Brand: Idec

1. Маҳсулот ба охир расидview

The Idec RJ2S-CL-D12 is an 8A DPDT (Double Pole Double Throw) electromechanical relay designed for general purpose switching applications. It operates on a 12VDC coil voltage and features a compact design suitable for various industrial electrical control systems. This relay is typically used for switching higher power circuits with a low power control signal, providing isolation between control and load circuits.

Idec RJ2S-CL-D12 Electromechanical Relay

Figure 1: Idec RJ2S-CL-D12 Electromechanical Relay. This image shows the compact, transparent yellow casing of the relay, revealing the internal coil and contacts, with the pin base visible at the bottom.

2. Маълумот оид ба бехатарӣ

Always observe the following safety precautions when installing, operating, or maintaining the relay:

3. Танзим ва насб

The RJ2S-CL-D12 relay is designed for socket mounting. Follow these steps for proper installation:

  1. Қатъи барқ: Before beginning, ensure that all power to the circuit where the relay will be installed is completely disconnected and locked out.
  2. Интихоби розетка: Use a compatible relay socket (e.g., Idec SY4S-05 or similar) that matches the relay's pin configuration.
  3. Mounting the Socket: Securely mount the relay socket to a DIN rail or panel using appropriate fasteners.
  4. Wiring the Socket: Ҷилди назоратро пайваст кунедtage (12VDC) to the coil terminals of the socket. Refer to the socket's wiring diagram for correct polarity. Connect the load circuit wires to the appropriate contact terminals (common, normally open, normally closed) as required by your application. The DPDT configuration provides two independent sets of contacts.
  5. Inserting the Relay: Carefully align the relay pins with the corresponding holes in the socket. Gently push the relay into the socket until it is fully seated. Do not force the relay, as this may bend or damage the pins.
  6. Тафтиш: Double-check all wiring connections for correctness and security before restoring power.

4. Дастурҳои истифодабарӣ

The RJ2S-CL-D12 relay operates by energizing its coil, which then actuates the internal contacts to switch the connected load circuits.

5. Нигоҳдорӣ

Electromechanical relays like the RJ2S-CL-D12 are generally low-maintenance devices. However, periodic inspection can help ensure reliable operation.

6. Баррасии мушкилот

If the RJ2S-CL-D12 relay is not functioning as expected, consider the following troubleshooting steps:

МушкилотСабаби эҳтимолӣҲалли
Relay coil does not energize (no click, no indicator light)
  • No 12VDC power to coil terminals.
  • Ҳаҷми печи нодурустtage (e.g., AC instead of DC, or wrong DC voltagва).
  • Loose or incorrect wiring to coil.
  • Кабели вайроншуда.
  • Verify 12VDC supply at coil terminals with a multimeter.
  • Боварӣ ҳосил кунед, ки ҷилди дурустtage and polarity are applied.
  • Check all coil wiring connections.
  • Replace relay if coil is confirmed damaged.
Relay energizes but load does not switch
  • Incorrect wiring of load contacts.
  • Open circuit in load path.
  • Load current exceeds relay contact rating.
  • Damaged contacts.
  • Review wiring diagram and verify load connections.
  • Check continuity of load circuit.
  • Ensure load current is within 8A rating.
  • Replace relay if contacts are damaged.
Relay buzzes or chatters
  • Insufficient or fluctuating coil voltage.
  • Ҳаҷми печи нодурустtage type (e.g., AC ripple on DC).
  • Verify stable 12VDC supply to the coil.
  • Ensure power supply is clean DC.

7. Мушаххасоти

АттрибутАрзиш
Рақами моделRJ2S-CL-D12
БрендIdec
Навъи тамосDPDT (Double Pole Double Throw)
Coil Voltage12VDC
Рейтинги ҷорӣ8 Amps
Муқовимати coil271 Ом
Андозаҳо (тақрибан)28.8 x 12.7 x 33 мм
Режими амалиётАвтоматӣ
ИстеҳсолкунандаIDEC

8. Кафолат ва дастгирӣ

Specific warranty terms and conditions for the Idec RJ2S-CL-D12 relay are not provided in this manual. For detailed warranty information, technical support, or service inquiries, please contact Idec Corporation directly or refer to their official webсайт.

You may also contact the authorized distributor or seller from whom you purchased the product for assistance.

Ҳуҷҷатҳои марбут - RJ2S-CL-D12

Пешview Дастури интихоби реле IDEC
A comprehensive guide to selecting IDEC relays, covering various series like RV8H, RJ, RH, RU, RR, RL, RY, RF, and RSC solid-state relays. It details specifications, features, and cross-references for industrial applications.
Пешview Гузаришҳои Силсилаи IDEC YW & Чароғҳои пилотӣ - Каталоги ҳамаҷонибаи маҳсулот
Силсилаи IDEC YW-и Ø22 ва Ø30 ва чароғҳои пилотӣ, аз ҷумла коммутаторҳои қатъи фавқулодда, тугмаҳо, калидҳои селекторӣ, калидҳои селекторӣ ва чароғҳои пилотиро омӯзед. View мушаххасот, рақамҳои қисмҳо, андозаҳо ва лавозимот.
Пешview Релеҳои универсалии IDEC RU Series: Хусусиятҳо, мушаххасот ва барномаҳо
Дастури мукаммал оид ба релеҳои универсалии миниатюрии IDEC RU Series, ки тафсилоти хусусиятҳои онҳо, мушаххасоти техникӣ, хатҳои умри барқ, андозаҳо, рақамҳои қисмҳо, розеткаҳои мувофиқ ва чораҳои бехатарӣ барои автоматизатсияи саноатӣ мебошад.
Пешview IDEC RF1V Force Guided Relays & SF1V Relay Sockets | Safety Circuit Components
Explore IDEC's RF1V Force Guided Relays and SF1V Relay Sockets, designed for flexible and reliable safety circuit construction. Features include EN50205 compliance, fast response, and shock resistance.
Пешview IDEC SmartRelay FL1F: IIoT-Ready Compact Programmable Relay
Discover the IDEC SmartRelay FL1F, a versatile and compact IIoT-ready programmable relay designed for efficient automation, control, and remote monitoring. This document details its features, extensive I/O capabilities, communication protocols (Modbus TCP, MQTT), web server functionality, and comprehensive technical specifications.
Пешview IDEC SmartRelay FL1F Series User's Manual
Comprehensive user's manual for the IDEC SmartRelay FL1F series, covering installation, wiring, programming, functions, and software for industrial logic modules. Includes technical specifications and operational guidelines.