This manual provides detailed instructions for the installation, operation, and maintenance of the Systemair K 125M Sileo duct fan. The K-series fans are designed for efficient air handling in duct systems, featuring robust construction and reliable performance. Please read this manual thoroughly before installation and operation to ensure safe and correct use of the product.

2. Маълумот оид ба бехатарӣ

Always adhere to local electrical codes and safety regulations during installation and operation. Disconnect power before performing any maintenance or installation procedures.

  • The fan is equipped with built-in thermal contacts with automatic reset to protect the motor from overheating.
  • The airtight, folded galvanized steel housing (leak rate according to tightness class C, EN 12237:2003) allows for installation in damp rooms and outdoor areas.
  • The motor has a protection class of IP44.
  • Ба заминкании дуруст таъмин кунед.
  • Агар ягон қисми он вайрон шуда бошад, вентиляторро истифода набаред.

3. Хусусиятҳои маҳсулот

The Systemair K 125M Sileo duct fan offers the following key features:

  • Speed-Controllable: Can be controlled using a stepless thyristor or a 5-step transformer.
  • Муҳофизати гармидиҳии муттаҳидшуда: Built-in thermal contacts with automatic reset for motor safety.
  • Насби чандир: Installation is possible in any mounting position.
  • Outdoor and Damp Room Use: Муносиб барои беруни бино ва гamp environments due to its airtight housing and IP44 motor protection.
  • Reliable and Maintenance-Free: Designed for dependable operation with minimal maintenance requirements.
  • Тарҳрезии самаранок: Features backward-curved impeller blades and external rotor motors for optimal performance.
  • Монтажи осон: Includes a mounting bracket for straightforward installation and removal.

4. Мушаххасоти техникӣ

ПараметрАрзиш
МоделиK 125M Sileo
Ҷилдиtage230В
Басомад50 Гц
Марҳила1~
Electrical Power Consumption (P1)28.2 Вт
ҷорӣ0.164А
Max. Volume Flow187 м³/соат
Суръат2491 1/дақ
Вазн2.3 кг
Max. Medium Temperature70°С
Max. Medium Temperature (Speed Controlled)70°С
Sound Pressure Level at 3m (20m³ Sabin)34.2дБ(А)
Синфи изолятсияB
Protection Class, MotorIP44
Диаметри пайвастшавӣ125мм
Energy Class (Basic Unit)F
Energy Class (Basic Unit Option)C
ErP ReadyErP 2018
ИстеҳсолкунандаSystemair
ASINB07ZP91RP2
Маълумотномаи истеҳсолкунанда103573
Table showing maximum efficiency and operating data for the Systemair K 125M Sileo fan

Figure 4.1: Maximum Efficiency and Operating Data Table. This table provides detailed performance metrics including airflow, static pressure, power consumption, and sound levels at various frequencies.

Energy efficiency labels for Systemair K125M Sileo fan, showing F and C ratings

Figure 4.2: Energy Efficiency Labels. Displays the energy class ratings for the basic unit (F) and an optional configuration (C), along with sound power level (29 dB) and airflow (90 m³/h).

5. Насб ва насб

The K-series fans are designed for easy duct mounting. Ensure the installation location is suitable and allows for proper airflow and access for maintenance.

Systemair K 125M Sileo duct fan, a cylindrical fan with a control box on top

Figure 5.1: Systemair K 125M Sileo Duct Fan. This image shows the main product view of the cylindrical duct fan with its integrated control box.

5.1 Васлкунӣ

  • The fan comes with a mounting bracket to facilitate easy installation and removal.
  • All K-fans feature duct connections at least 25 mm long, compliant with EN 1506:1997, for secure attachment to ductwork.
  • For vibration-free connection to the duct system, consider using FK connecting sleeves (available as accessories).
  • The fan can be installed in any mounting position (horizontal, vertical, etc.).
Technical drawing showing dimensions of the Systemair K 125M Sileo fan

Figure 5.2: Dimensions Diagram. This technical drawing illustrates the various dimensions (A, B, C, D, E, F) of the fan, crucial for planning installation space and duct connections.

5.2 Пайвастшавӣ ба барқ

Connect the fan to a 230V, 50Hz, single-phase power supply. Ensure all wiring is done by a qualified electrician and complies with local regulations. The fan is equipped with an external rotor motor.

6. Амалиёт

The Systemair K 125M Sileo fan is designed for continuous operation within its specified parameters.

6.1 Назорати суръат

The fan's speed can be controlled to adjust airflow as needed. This can be achieved using:

  • A stepless thyristor controller.
  • A 5-step transformer.

Refer to the performance diagrams to understand the fan's behavior at different operating points.

Performance curves for the Systemair K 125M Sileo fan showing static pressure and power versus volume flow

Figure 6.1: Performance Diagrams. These graphs illustrate the fan's static pressure (P stat.) and power consumption (P) in relation to the volume flow (Q), providing insight into its operational characteristics.

7. Нигоҳдорӣ

The Systemair K 125M Sileo fan is designed to be reliable and largely maintenance-free. However, periodic checks can help ensure optimal performance and longevity.

  • Тозакунӣ: Periodically inspect the impeller and housing for dust and debris accumulation. Clean gently with a soft brush or cloth. Ensure power is disconnected before cleaning.
  • Санҷиш: Пайвастҳои барқиро аз нигоҳи маҳкамӣ ва аломатҳои фарсудашавӣ тафтиш кунед.
  • Подшипникҳо: The fan's motor bearings are typically sealed and do not require lubrication.

8. Баррасии мушкилот

If you encounter issues with your Systemair K 125M Sileo fan, consider the following common troubleshooting steps:

  • Fan not starting: Check the power supply, circuit breaker, and electrical connections. Ensure the thermal contacts have not tripped (they reset automatically).
  • Кам шудани гардиши ҳаво: Inspect ducts for obstructions or leaks. Check if the fan speed controller is set correctly.
  • Садо ё ларзиши ғайриоддӣ: Ensure the fan is securely mounted. Check for any foreign objects in the impeller or housing. Verify that the FK connecting sleeves are properly installed if used.
  • Аз ҳад зиёд гармшавӣ: Ensure adequate ventilation around the fan. Check for obstructions that might restrict airflow. The built-in thermal contacts should protect the motor.

If problems persist after performing these checks, contact qualified service personnel or Systemair support.

9. Кафолат ва дастгирӣ

For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your Systemair dealer. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or service inquiries, please contact your local Systemair representative or the seller from whom you purchased the product. Provide the model number (K 125M Sileo) and serial number (if applicable) when seeking support.

Ҳуҷҷатҳои марбут - K 125M Sileo

Пешview Systemair K 315 L SILEO вентилятори каналҳои марказӣ - Мушаххасоти техникӣ ва андозаҳо
Мушаххасоти муфассали техникӣ, андозаҳо, диаграммаҳои ноқилҳо ва замимаҳо барои мухлиси канали марказгурези Systemair K 315 L SILEO. Маълумоти кор, сатҳи садо ва маълумоти насбкуниро дар бар мегирад.
Пешview Systemair RVK Fan Circular Duct: Дастурҳои насб ва истифода
Ин дастур насб, истифода ва нигоҳдории вентиляторҳои каналҳои даврашакли Systemair RVK-ро муфассал шарҳ медиҳад. Он протоколҳои бехатарӣ, пайвастҳои барқӣ, ба кор андохтан, ҳалли мушкилот ва таҷрибаҳои беҳтаринро барои кори беҳтарини системаҳои вентилятсия фаро мегирад.
Пешview Systemair DXRE/DXRE-D Duct Cooler Installation and Maintenance Manual
This document provides comprehensive installation, mounting, and cleaning instructions for the Systemair DXRE/DXRE-D duct cooler, designed for central cooling of ventilation air and compatible with outdoor units for heating and cooling.
Пешview Systemair Internet Access Module (IAM) User Manual
Comprehensive user manual for the Systemair Internet Access Module (IAM) for SAVE residential ventilation units, covering installation, configuration, network connectivity, Modbus TCP mode, and mobile app integration.
Пешview Systemair SAVE VTR 300/B Дастур оид ба насби хидмат ва лавозимот
Дастури мукаммал оид ба насб, танзим ва хидматрасонии воҳиди вентилятсияи гармидиҳии Systemair SAVE VTR 300/B, ки бехатарӣ, маълумоти техникӣ, амалиёт ва лавозимотро дар бар мегирад.
Пешview Systemair SAVE VTR 150/B Installation Manual
Comprehensive installation manual for the Systemair SAVE VTR 150/B heat recovery ventilation unit. Covers general information, technical specifications, dimensions, mounting procedures for various kitchen hoods, electrical connections, system checks, commissioning, and disposal guidelines.