SIMPLEX 4010 9403

Simplex 4010-9403 4010ES Addressable Fire Control Unit User Manual

Model: 4010 9403 | Brand: SIMPLEX

1. Муқаддима

This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4010-9403 4010ES Addressable Fire Control Unit. This unit is designed to provide reliable fire detection and alarm capabilities for various applications. Please read this manual thoroughly before attempting any installation or operation.

2. Маълумот оид ба бехатарӣ

Always adhere to local and national electrical codes and fire safety regulations during installation and operation. Only qualified personnel should install, service, or maintain this equipment. Disconnect all power sources before servicing. Failure to follow these instructions may result in injury, death, or property damage.

3. Маҳсулот ба охир расидview

The Simplex 4010ES Addressable Fire Control Unit (FCU) is a robust system designed for comprehensive fire detection and notification. It features an addressable loop for connecting various fire alarm devices such as smoke detectors, heat detectors, and manual pull stations. The unit is housed in a durable red enclosure with a clear LED display for status indication.

Пеш view of the Simplex 4010ES Addressable Fire Control Unit, showing the red enclosure and the control panel with LED display and buttons.

Расми 3.1: Пеш view of the Simplex 4010ES Addressable Fire Control Unit. The unit is red with a dark grey control panel featuring a green LED display and various buttons and indicators.

The unit operates on 120V AC power and includes a battery backup system to ensure continuous operation during power outages. The front panel provides access to system controls, status indicators, and a key lock for secure access.

4. Танзим ва насб

4.1 Кушодан ва тафтиш

Carefully unpack the fire control unit and inspect it for any signs of shipping damage. Verify that all components listed in the packing slip are present. The unit's part number is 0743904, and the PID is 4010-9403, as indicated on the packaging.

Shipping label on a cardboard box for the Simplex 4010-9403, showing PID, Part No. 0743904, and Serial Number.

Figure 4.1: Product identification label on the shipping box, displaying the PID (4010-9403), Part No. (0743904), and serial number for the Simplex 4010ES FACP.

Accessories included with the Simplex 4010ES unit, including a key and cable ties, with a partial view of the control panel in the background.

Figure 4.2: Included accessories such as the system key and cable ties, essential for installation and secure operation.

4.2 Ҷойгиркунии дастгоҳ

Select a clean, dry, and secure location for mounting the unit, away from direct sunlight and heat sources. Ensure adequate space for ventilation and access for servicing. Mount the unit securely to a wall using appropriate fasteners, ensuring it is level and stable.

4.3 Пайвастҳои барқӣ

The unit requires a 120V AC power supply. All wiring must comply with national and local electrical codes. Connect the main power supply to the designated terminals inside the unit. Ensure proper grounding. Install backup batteries as per the wiring diagram provided with the unit.

4.4 Ноқилҳои дастгоҳ

Connect addressable fire alarm devices (detectors, modules, pull stations) to the unit's addressable loop terminals. Follow the specific wiring diagrams for each device type to ensure correct addressing and functionality. Verify all connections are secure before applying power.

5. Дастурҳои истифодабарӣ

5.1 Фаъолсозии барқ

Once all connections are complete and verified, apply main AC power to the unit. The unit will perform a self-diagnostic test. Observe the LED indicators for system status. The green 'POWER' LED should illuminate steadily.

5.2 Фаҳмидани нишондиҳандаҳо

5.3 Ҷавоб додан ба ҳушдорҳо

  1. Upon an alarm, the red ALARM LED will illuminate, and audible signals will activate.
  2. Immediately investigate the cause of the alarm.
  3. To silence the audible alarm, press the ХОМУШ тугма.
  4. Once the cause of the alarm is resolved, press the АЗ НАВОР КУНЕД button to clear the alarm condition and restore the system to normal operation.
  5. If the alarm persists or cannot be reset, refer to the Troubleshooting section or contact qualified service personnel.

6. Нигоҳдорӣ

Regular maintenance is crucial for the reliable operation of your fire control unit. Perform the following checks periodically:

7. Баррасии мушкилот

This section provides solutions to common issues you may encounter with your Simplex 4010ES unit. For problems not listed here, contact qualified service personnel.

МушкилотСабаби эҳтимолӣҲалли
Unit has no power (no LEDs).No AC power; tripped circuit breaker; dead battery.Check AC power supply; reset circuit breaker; check/replace backup battery.
TROUBLE LED is illuminated.Wiring fault; device malfunction; low battery.Check wiring connections; inspect devices; test/replace battery. Consult system logs for specific trouble codes.
Ҳушдорҳои бардурӯғ.Dust/debris in detectors; environmental factors; faulty device.Clean detectors; identify and mitigate environmental factors (e.g., steam); replace faulty device.
System will not reset.Alarm condition still present; system fault.Ensure all alarm conditions are cleared; check for trouble signals. If issue persists, contact service.

8. Мушаххасоти

ХусусиятТафсилот
БрендSIMPLEX
Рақами модел4010 9403
Рақами қисмS40109403
UPC767571882953
Манбаи нерӯ120V AC, Battery Powered (Backup)
РангиСурх
Навъи ҳушдорВизуалӣ
ИстеҳсолкунандаSIMPLEX
Миқдори бастаи адад1

9. Кафолат ва дастгирӣ

For specific warranty information regarding your Simplex 4010-9403 4010ES Addressable Fire Control Unit, please refer to the documentation provided at the time of purchase or contact your authorized Simplex distributor. Simplex is committed to providing excellent customer service and support for its products.

If you require technical assistance, service, or have questions regarding your unit, please contact Simplex customer support or an authorized service provider. Contact information can typically be found on the manufacturer's official webсайт ё тавассути дистрибютори маҳаллии худ.

Ҳуҷҷатҳои марбут - 4010 9403

Пешview Simplex 4010ES Addressable Fire Detection and Control Units: Modules and Accessories
Comprehensive guide to Simplex 4010ES Addressable Fire Detection and Control Units, detailing features, modules, accessories, specifications, and installation.
Пешview Simplex IDNet Signal IAM Installation Instructions
Detailed installation instructions for the Simplex 4090-9007 IDNet Addressable Signal Individual Adapter Module (Signal IAM), covering address setting, wiring configurations for Class A and Class B Notification Appliance Circuits (NACs), and mounting procedures. This guide provides essential information for integrating the Signal IAM with fire alarm control panels and notification appliances.
Пешview Истгоҳҳои дастии суроғашавандаи симплекс: Қисмҳои периферии IDNet/MAPNET II
Истгоҳҳои сигнализатсияи сӯхторхомӯшкунии дастӣ бо суроғаи Simplex-ро омӯзед, хусусиятҳои онҳо, намудҳои амали яккарата/дукарата, имконоти NO GRIP ва мутобиқат бо системаҳои IDNet/MAPNET II-ро муфассал шарҳ диҳед. Маълумоти васлкунӣ ва хусусиятҳоро дар бар мегирад.
Пешview Simplex 4010ES: Системаҳои фармондеҳии автоматии нобудшавӣ
Дастури техникаи Simplex 4010ES тафсилоти модулҳои модулҳои фармондеҳии рехт, системаҳои аз байн рафтани автоматӣ, шеваҳои тозакунӣ ва пешгирикунанда, мушаххасоти авҷ, гомологҳо ва схемаҳои câblage.
Пешview Варақаи маълумотии воҳиди муайянкунӣ ва назорати сӯхтор Simplex 4007ES
Варақаи маълумоти муфассал барои воҳиди муайянкунӣ ва назорати сӯхтор Simplex 4007ES, ки қобилиятҳо, хусусиятҳо, мушаххасот ва тафсилоти насби MX Digital Addressable Initiation ва Addressable Ogohlantirishро дар бар мегирад.
Пешview Simplex 4090-9007 IDNet Signal IAM: Addressable Module for Fire Alarm Systems
Detailed technical specifications and features for the Simplex 4090-9007 IDNet Signal Individual Addressable Module (IAM), designed for enhanced selective signaling and audio control in Simplex 4100ES, 4010ES, 4100U, and 4008 Series fire alarm control panels. Includes wiring, operation, and mounting information.