Tektronix TBS2074B

Дастури корбарии осциллографи рақамии Tektronix TBS2074B

Model: TBS2074B | Brand: Tektronix

1. Муқаддима

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Расми 1.1: Пеш view of the Tektronix TBS2074B Digital Oscilloscope.

2. Хусусиятҳои асосӣ

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Танзимот

3.1 Кушодани баста

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Пайваст кардани қувваи барқ

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

Қафо view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Фаъолсозии ибтидоӣ

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Амалиёт

4.1 Интерфейси корбар тамом шудview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Андозаҳои асосӣ

To perform a basic measurement:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 Функсияҳои пешрафта

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Пайвастшавӣ

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Расми 5.1: Наздик view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Нигоҳдорӣ

6.1 Тозакунӣ

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Нигоҳдорӣ

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Баррасии мушкилот

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

МушкилотСабаби эҳтимолӣҲалли
Не қудратPower cord not connected; Power outlet fault; Internal fuse blownCheck power cord connection; Test power outlet; Contact service for fuse replacement
Шакли мавҷ нишон дода нашудаастProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Шакли мавҷи ноустуворIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Мушаххасоти

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

МушаххасотиАрзиш
ИстеҳсолкунандаTektronix
Рақами моделTBS2074B
Маҷрои маҷрои70 MHz (Upgradeable to 200 MHz with option)
Каналҳои аналогӣ4
Макс Сample Rate2 GS/s (half channel), 1 GS/s (all channels)
Дарозии сабт5 M points
Намоиш9-inch WVGA Color Display
Automatic Measurements32 намуд
Интерфейси пробTekVPI
ПайвастшавӣUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Вазни ашё3 килограмм
Андозаҳои бастаҳо50 х 40 х 26 см
Компонентҳои дохилшудаStandard Accessory KIT
Batteries UsedНе
First Available Date (Amazon.co.jp)2020/5/11

9. Кафолат ва дастгирӣ

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support

Ҳуҷҷатҳои марбут - TBS2074B

Пешview Tektronix 7L12 Spectrum Analyzer Instruction Manual
This document provides comprehensive instructions for operating, testing, calibrating, and servicing the Tektronix 7L12 Spectrum Analyzer, a dual-width plug-in unit for 7000-Series Oscilloscopes. It details specifications, front panel controls, operational procedures, calibration methods, and applications for RF signal analysis.
Пешview Tektronix 5 Силсилаи B MSO: Мушаххасот ва санҷиши иҷроиш
Мушаххасоти муфассал ва тартиби санҷиши кор барои осциллографҳои Tektronix 5 Series B MSO, аз ҷумла моделҳои MS054B, MS056B ва MS058B. Маълумоти муҳими техникӣ барои инженерҳо ва техникҳо.
Пешview Tektronix 2235 Oscilloscope Service Manual
Comprehensive service manual for the Tektronix 2235 Oscilloscope. Includes detailed specifications, operating instructions, theory of operation, performance checks, adjustment procedures, maintenance, troubleshooting, and parts lists for qualified service personnel.
Пешview Tektronix 3 Силсилаи Кӯмаки осциллографи домени омехта (MD032, MD034)
Дастури корбар барои осциллографи Tektronix 3 Series Mixed Domain (MD032, MD034), ки тафсилоти хусусиятҳо, амалиёт, конфигуратсия ва бартарафсозии мушкилот барои ин асбоби пешрафтаи санҷиш ва андозагирӣ мебошад.
Пешview Tektronix 3 Series MDO Oscilloscope MD032 & MD034: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 3 Series Mixed Domain Oscilloscopes (MDO32 and MDO34), covering analog and digital channel performance, acquisition systems, trigger capabilities, and more.
Пешview Tektronix TBS1000C Series Oscilloscopes User Manual
This comprehensive User Manual for the Tektronix TBS1000C Series Oscilloscopes provides detailed guidance on installation, operation, features, safety, measurements, data saving, and troubleshooting. Essential for engineers and technicians using these digital oscilloscopes for electronic design and analysis.