Everwell MGTC2423X-20

Дастури корбарии кондитсионери мини-сплитии EVERWELL MGTC2423X-20 Inverter

Model: MGTC2423X-20, MGTC-20, MGTC2423E-20, MGTC2423C-20

1. Муқаддима

This manual provides essential information for the installation, operation, and maintenance of your EVERWELL MGTC2423X-20 Inverter Mini-Split Air Conditioner. This unit is designed for cooling only, offering 24,000 BTU capacity with a high efficiency rating of 20 SEER. It operates on a 220V/1Ph/60Hz power supply and uses R410A refrigerant.

Хусусиятҳои асосӣ инҳоянд:

  • Full DC Inverter Technology: Enables up to 65% energy savings.
  • Самаранокии баланди энергия: 20 SEER rating for optimal performance.
  • Wi-Fi Ready: Control your unit remotely via a smartphone or tablet app.
  • Gold Fin Technology: Extends the functional life of the equipment, especially in high humidity and salinity environments.
  • Noiseless Technology: Ensures quiet operation.
  • AHRI and ETL Certified: Guarantees quality and performance standards.
  • Featured Operations: Includes ECO, SUPER, SLEEP, and TIMER modes for enhanced control and energy management.
Everwell MGTC2423X-20 Mini-Split Air Conditioner with indoor unit, outdoor unit, and installation kit components

Расми 1: Зиёдview of the Everwell MGTC2423X-20 Mini-Split Air Conditioner system, showing the indoor unit, outdoor unit, and included installation accessories.

2. Дастурҳои муҳим оид ба бехатарӣ

ОГОҲӢ: Риоя накардани ин дастурҳо метавонад боиси зарбаи барқ, сӯхтор ё ҷароҳати вазнин гардад.

  • Пеш аз истифода бурдани ин дастгоҳ ҳама дастурҳоро хонед.
  • This unit must be installed by a qualified and licensed HVAC technician in accordance with all local and national electrical and building codes.
  • Ensure the power supply matches the unit's requirements (220V/1Ph/60Hz).
  • Дастгоҳро бо сими барқ ​​​​ё васлаки вайроншуда кор накунед.
  • Ангуштон ё ашёро ба вуруд/хӯроқи ҳаво нагузоред.
  • Кӯшиш накунед, ки дастгоҳро худатон таъмир ё тағйир диҳед. Ҳамаи хидматрасониро ба кормандони соҳибихтисос супоред.
  • Барои пешгирӣ кардани зарбаи барқ ​​ба заминкании дурустро таъмин кунед.
  • Маводҳои оташгирандаро аз дастгоҳ дур нигоҳ доред.

3. Дар қуттӣ чӣ мавҷуд аст

Your EVERWELL MGTC2423X-20 Mini-Split Air Conditioner package includes the following components:

  • Indoor Evaporating Unit
  • Воҳиди конденсатсионӣ дар беруни бино
  • Wireless Control Remote
  • Кабели алоқа
  • Copper Tubing (3m / 9.8 ft)
  • Шамъро холӣ кунед
  • Лентаи изолятсия
  • Остин девор
Components of the Everwell Mini-Split installation kit including copper tubing, communication cable, and insulation

Расми 2: Муфассал view of the installation kit components, including pre-flared copper lines, communication wire, and drainage hose.

4. Насб ва насб

The EVERWELL MGTC2423X-20 is a split-system air conditioner. Due to the complexity involving refrigerant lines, electrical connections, and proper drainage, professional installation by a certified HVAC technician is mandatory to ensure safe and efficient operation and to maintain warranty validity.

4.1 Санҷишҳои пеш аз насб

  • Verify the power supply at the installation site matches the unit's requirements (220V/1Ph/60Hz).
  • Фазои мувофиқро ҳам барои воҳидҳои дарунӣ ва ҳам берунӣ таъмин кунед, ки ба ҷараёни дурусти ҳаво ва дастрасии нигоҳдорӣ имкон медиҳад.
  • Confirm the installation location complies with all local building and electrical codes.

4.2 Насбкунӣ ба охир расидview (For Qualified Technicians)

  1. Mount the indoor unit securely on a wall, ensuring it is level and has proper drainage.
  2. Install the outdoor condensing unit on a stable, level surface, ensuring proper clearance from obstructions.
  3. Connect the copper refrigerant lines between the indoor and outdoor units. Ensure proper flaring and torque for leak-free connections.
  4. Connect the communication cable and power wiring according to the wiring diagram provided in the full installation manual.
  5. Perform a vacuum evacuation of the refrigerant lines to remove air and moisture.
  6. Open the refrigerant service valves.
  7. Check for leaks using appropriate methods.
  8. Connect the drain hose from the indoor unit to a suitable drainage point.
  9. Restore power and test the unit's operation.
Everwell Mini-Split indoor unit showing its sleek design and digital display Everwell Mini-Split outdoor unit with fan and refrigerant line connections

Figure 3: Indoor (left) and Outdoor (right) units of the Everwell Mini-Split system, illustrating their design and connection points.

5. Дастурҳои истифодабарӣ

Your Everwell Mini-Split can be operated using the included wireless remote control or via the Wi-Fi app on your smartphone/tablet.

5.1 Амалиёти идоракунии дурдаст

The remote control allows you to adjust settings, change modes, and set timers. Refer to the remote control's specific manual for detailed button functions.

  • Тугмаи фурӯзон/хомӯш: Дастгоҳро фаъол ё хомӯш мекунад.
  • Тугмаи MODE: Cycles through available operating modes (e.g., Cool, Fan).
  • Танзими ҳарорат: Истифода баред + ва - тугмаҳои барои муқаррар кардани ҳарорати дилхоҳ.
  • Тугмаи FAN: Суръати вентиляторро танзим мекунад.
  • Тугмаи SWING: Controls the louver swing for air distribution.
  • Тугмаи ТАЙМЕР: Sets the auto-on or auto-off time.
  • Тугмаи ЭКО: Activates energy-saving mode, optimizing operation for minimal power consumption.
  • Тугмаи SUPER: Initiates rapid cooling to quickly reach the desired temperature.
  • Тугмаи SLEEP: Adjusts temperature and fan speed for comfortable sleep conditions and energy saving overnight.

5.2 Идоракунии барномаи Wi-Fi

The unit is Wi-Fi ready, allowing remote control via a dedicated smartphone application. Download the "Smart Life - SmartHome" app from your device's app store (available for iOS and Android).

  1. Download and install the "Smart Life - SmartHome" app.
  2. Ҳисобро сабт кунед ва ворид шавед.
  3. Follow the in-app instructions to add your Everwell Mini-Split unit to your account. This typically involves putting the unit into pairing mode and connecting it to your home Wi-Fi network.
  4. Once connected, you can control the unit's functions (ON/OFF, mode, temperature, fan speed, timer, etc.) from anywhere with an internet connection.
Smartphone app interface for controlling the air conditioner and the physical remote control

Figure 4: The Everwell Mini-Split can be controlled via its dedicated smartphone app (left) or the included wireless remote control (right).

6. Нигоҳдорӣ

Нигоҳдории мунтазам кори беҳтаринро таъмин мекунад ва мӯҳлати хизмати кондитсионери шуморо дароз мекунад. Пеш аз анҷом додани ягон таъмир ҳамеша барқро ҷудо кунед.

6.1 Air Filter Cleaning (Monthly)

  • Панели пеши воҳиди дохилиро кушоед.
  • Филтрҳои ҳаворо хориҷ кунед.
  • Филтрҳоро бо истифода аз чангкашак тоза кунед ё онҳоро бо оби ширгарм ва шустушӯй нарм бишӯед.
  • Пеш аз ворид кардани дубора ба филтрҳо иҷозат диҳед, ки пурра хушк шаванд.

6.2 Outdoor Unit Cleaning (Seasonally)

  • Ҳама гуна партовҳоро (баргҳо, лой) аз атрофи воҳиди беруна тоза кунед.
  • Gently clean the outdoor coil fins with a soft brush or water hose. Be careful not to bend the fins.
  • Ensure the drainage holes at the base of the outdoor unit are clear.

6.3 Professional Servicing (Annually)

It is recommended to have a qualified HVAC technician perform an annual check-up, including refrigerant level checks, coil cleaning, and electrical connection inspections.

7. Баррасии мушкилот

Пеш аз тамос бо дастгирии муштариён, лутфан масъалаҳои зеринро тафтиш кунед:

Мушкилот Сабаби эҳтимолӣ Ҳалли
Дастгоҳ фурӯзон намешавад. No power; remote control batteries dead; circuit breaker tripped. Check power supply; replace remote batteries; reset circuit breaker.
хунуккунии нокифоя. Dirty air filters; blocked outdoor unit; windows/doors open; temperature setting too high. Clean air filters; clear obstructions from outdoor unit; close windows/doors; lower temperature setting.
Садои ғайриоддӣ. Loose parts; foreign object in fan; unit not level. Check for loose parts; inspect fan for obstructions (with power off); ensure unit is level. If noise persists, contact a technician.
Ихроҷи об аз воҳиди дохилӣ. шланги дренажии басташуда; насби нодуруст. Check and clear drain hose; contact a professional for installation inspection.

For issues not listed above or if solutions do not resolve the problem, please contact Everwell customer support or a qualified HVAC technician.

8. Мушаххасоти техникӣ

Хусусият Мушаххасоти
БрендEverwell
Рақамҳои намунавӣMGTC2423X-20, MGTC-20, MGTC2423E-20, MGTC2423C-20
Иқтидори хунуккунӣ24,000 BTU (2 тонна)
Таносуби мавсимии самаранокии энергия (SEER)20.00
Ҷилдиtage220V / 1 Phase / 60Hz
Намуди яхдонR410A
Навъи насбСистемаи тақсимшавӣ
Indoor Unit Dimensions (W×H×D)46.7 × 13.3 × 10.1 инч
Outdoor Unit Dimensions (W×H×D)36.2 × 14.9 × 27.5 инч
Хусусиятҳои махсусWi-Fi Ready, Gold Fin, Noiseless Technology, ECO, SUPER, SLEEP, TIMER Operations
СертификатсияҳоAHRI Certified, ETL Mark
EnergyGuide label for Everwell MGTC2423C-20 showing 20.00 SEER rating and installation restrictions

Figure 5: EnergyGuide label indicating the 20.00 SEER rating and states where installation is allowed.

9. Маълумот дар бораи кафолат

The EVERWELL MGTC2423X-20 Mini-Split Air Conditioner comes with a limited warranty:

  • Кафолати 5 сол компрессор
  • Қисмларга 2 йил кафолат

Important: Warranty is valid only with registered equipment and professional installation by a certified HVAC technician.

Everwell warranty details showing 5 years compressor and 2 years parts warranty, along with certifications like Wi-Fi, Inverter, GoldFin, AHRI, ETL, R410A, Noiseless

Figure 6: Warranty details and various certifications for the Everwell Mini-Split system.

10. Дастгирии муштариён

For technical assistance, warranty claims, or further inquiries, please contact Everwell customer support. Ensure you have your model number and purchase details ready when contacting support.

For the most up-to-date contact information, please visit the official Everwell webба сайт муроҷиат кунед ё ба ҳуҷҷатҳои хариди худ муроҷиат кунед.

Webсайт: www.everwellparts.com (Хурampистинод, истиноди воқеӣ метавонад фарқ кунад)

Ҳуҷҷатҳои марбут - MGTC2423X-20

Пешview Дастури хидматрасонии кондитсионер Everwell - Series MGTC
Дастури мукаммали хидматрасонӣ барои кондитсионерҳои силсилаи Everwell MGTC, ки моделҳои MGTC0913, MGTC0923, MGTC1213, MGTC1223, MGTC1823, MGTC2423 ва MGTC3623-ро дар бар мегирад. Тафсилоти амалиёт, чораҳои бехатарӣ, диаграммаҳои пайвастшавӣ, бартараф кардани мушкилот ва рӯйхати қисмҳоро дар бар мегирад.
Пешview Дастури корбар Everwell MGTC-20 Series Function Wi-Fi
Дастури корбар барои кондитсионерҳои Everwell MGTC-20 Series, ки тафсилоти танзими функсияи Wi-Fi, назорати барнома, идоракунии дастгоҳ ва ҳалли мушкилотро дар бар мегирад.
Пешview Дастурҳои насби насоси гармидиҳӣ ва кондитсионери Everwell Split System (15 SEER, R410A)
Comprehensive installation guide for Everwell 15 SEER Split System Heat Pump & Air Conditioner units (1.5-5 Tons, R410A). Covers dimensions, service space, piping, wiring, electrical characteristics, operation limits, installation procedures, location selection, refrigerant handling, vacuum drying, insulation, testing, and troubleshooting.
Пешview Дастури дастури кондитсионери навъи Everwell Split
Роҳнамои ҳамаҷониба барои кондитсионерҳои навъи Everwell, ки тафсилоти насб, истифода, чораҳои бехатарӣ, нигоҳдорӣ ва қадамҳои бартараф кардани мушкилотро дар бар мегирад.
Пешview Системаи идоракунии универсалии Everwell MCRC-002 барои кондитсионерҳои ҷудогонаи инвертории DC - Дастури истифода
Дастури истифода барои системаи идоракунии универсалии Everwell MCRC-002, ки барои кондитсионерҳои ҷудогонаи инвертерии DC пешбинӣ шудааст. Насб, ҳалли мушкилот, параметрҳои техникӣ ва кори агрегати дохилиро дар бар мегирад.
Пешview Дастури хидматрасонии кондитсионер Everwell Inverter
Дастури мукаммали хидматрасонии кондитсионерҳои Everwell Inverter, ки маълумоти техникӣ, насб, нигоҳдорӣ, бартараф кардани мушкилот ва функсияҳои муҳофизатиро барои моделҳои гуногун дар бар мегирад.