1. Маълумоти муҳим оид ба бехатарӣ

Read all instructions and warnings carefully before using the GOYOJO Scuba Diving Ventilator System. Failure to follow these instructions may result in serious injury or death. This device is intended for recreational diving and snorkeling within specified limits.

Illustration showing divers at different depths, indicating safe diving limits for snorkelers (2-3 meters) and experienced divers (7-10 meters) with the GOYOJO system.

Figure 1: Recommended Diving Depth Limits. Novice snorkelers can dive to 2-3 meters, while experienced divers can reach 7-10 meters.

2. Маҳсулот ба охир расидview ва ҷузъҳо

The GOYOJO Scuba Diving Ventilator System is a compact, tankless underwater breathing device designed to supply air from the surface. It consists of a floating air compressor unit, a breathing hose, a regulator, and a Buoyancy Control Device (BCD) vest.

Унсурҳои асосӣ:

Diagram showing the labeled components of the GOYOJO Scuba Diving Ventilator System, including the ventilator unit, 14m telescopic pipe (hose), straps, activated carbon filter, and respirator (regulator).

Figure 2: System Components. Key parts include the ventilator unit, hose, regulator, and BCD.

Close-up images of the GOYOJO ventilator unit showing its dimensions (42cm x 42cm x 15cm), waterproof switch, battery indicator, and soft latex handle.

Figure 3: Ventilator Unit Details. Features include a waterproof switch, battery indicator, and soft handle for portability.

3. Насбкунӣ ва васлкунӣ

Follow these steps to prepare your GOYOJO Scuba Diving Ventilator System for use.

3.1 Пур кардани батарея

  1. Ensure the ventilator unit is dry before charging.
  2. Connect the charger to the charging port on the ventilator unit.
  3. Пуркунандаи барқро ба васлаки стандартии барқ ​​пайваст кунед.
  4. The battery indicator will show charging progress. A full charge for the 40000mAh battery takes approximately 1.5 hours to reach 80% capacity, providing up to 2.7 hours of operation.
  5. Disconnect the charger once fully charged or before use.

3.2 Assembling the System

  1. Пайваст кардани шланг: Securely attach one end of the breathing hose to the air outlet on the ventilator unit.
  2. Танзимгари пайвастшавӣ: Attach the other end of the breathing hose to the breathing regulator. Ensure all connections are tight to prevent air leaks.
  3. Attach BCD: If using the BCD vest, connect the regulator and hose assembly to the BCD's air inlet. Adjust the BCD straps for a comfortable and secure fit.
  4. Санҷиши филтр: Verify that the activated carbon filter is correctly installed in the air line.
The complete GOYOJO Scuba Diving Ventilator System laid out, showing the floating ventilator unit, the coiled air hose, the BCD vest, and the breathing regulator.

Figure 4: Fully Assembled System. The ventilator unit, hose, BCD, and regulator are connected.

4. Амалиёт

This section details how to operate your GOYOJO Scuba Diving Ventilator System safely and effectively.

4.1 Санҷишҳои пеш аз ғаввосӣ

4.2 Activating the System

  1. Place the ventilator unit on the water surface. It is designed to float.
  2. Press the waterproof power switch on the ventilator unit to turn it on. The power display will illuminate.
  3. Listen for the sound of the air pump activating.

4.3 Underwater Breathing

4.4 Buoyancy Control with BCD

4.5 Post-Dive

Video 1: Scuba Diving Ventilator System in Use. This video demonstrates the practical application of the GOYOJO diving ventilator system underwater.

5. Нигоҳдорӣ ва нигоҳдорӣ

Proper maintenance ensures the longevity and safe operation of your diving system.

5.1 Тозакунӣ

5.2 Нигоҳубини батарея

5.3 Иваз кардани филтр

5.4 Нигоҳдорӣ

6. Баррасии мушкилот

This section addresses common issues you might encounter with your GOYOJO Scuba Diving Ventilator System.

МушкилотСабаби эҳтимолӣҲалли
No air from regulatorVentilator unit not turned on; Low battery; Hose disconnected or kinked; Regulator malfunction.Ensure unit is on; Charge battery; Check hose connections and for kinks; Inspect regulator for damage.
Unit not floating correctlyImproper placement; Damage to flotation device.Ensure unit is placed flat on the water surface; Inspect for damage and contact support if necessary.
Вақти кӯтоҳи амалиётBattery not fully charged; Aging battery.Ensure battery is fully charged before use; Consider battery replacement if performance degrades significantly.
Water in air inletUnit submerged or splashed excessively.Ensure the unit remains floating on the surface; The unit is designed to prevent water ingress, but excessive submersion should be avoided.

7. Мушаххасоти техникӣ

The following specifications apply to the GOYOJO Scuba Diving Ventilator System, Model Z270BCD 2.7 (Ordinary Model).

ХусусиятМушаххасоти
БрендГОЁЖО
Рақами моделZ270BCD 2.7
Вақти максималии корӣ2.7 соат
Иқтидори батарея40000 мАч
Ҷилди номиналӣtageDC 11.1V
Maximum Dive Depth10 метр
Вазни маҳсулот6.5 кг (14.33 фунт)
Қувваи номиналӣ180 Вт
Таъмини ҳаво52 литр / дақиқа
Андозаҳо (L x W x H)40 x 40 x 15 см (16.53 x 16.53 x 5.9 инч)
A table showing product parameters for two models, Q1 (Ordinary) and Q2 (Enhanced), detailing working time, electricity, battery capacity, rated voltage, maximum dive depth, product weight, rated power, air supply, and size.

Figure 5: Product Parameter Table. Specifications for the Ordinary (Q1) and Enhanced (Q2) models.

8. Кафолат ва дастгирӣ

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact GOYOJO customer service through the retailer where the product was purchased. Keep your proof of purchase for warranty claims.

Ҳуҷҷатҳои марбут - Z270BCD 2.7

Пешview GOYOJO 0.5L Mini Scuba Tank Universal Manual
Comprehensive user manual for the GOYOJO 0.5L Mini Scuba Tank Kits, covering safety, assembly, operation, maintenance, troubleshooting, and warranty information.
Пешview Goyojo GYJ-R Energy Dispersive X-ray Spectrometer - Technical Specifications
Detailed technical specifications and features of the Goyojo GYJ-R Energy Dispersive X-ray Spectrometer (EDXRF), including hardware, software, and RoHS analysis capabilities. This document outlines the product's performance indicators, operational conditions, and after-sales service.
Пешview GOYOJO Thermal Imaging Monocular User's Manual
Explore the GOYOJO Thermal Imaging Monocular with this comprehensive user's manual. Learn about its features, specifications, safety guidelines, and operating instructions for effective thermal imaging in outdoor environments.
Пешview NVG10 Head-Mounted Digital Night Vision Device User Manual
User manual for the GOYOJO NVG10 Head-Mounted Digital Night Vision Device, detailing its features, operation, specifications, and precautions. Includes setup, usage, and maintenance information.
Пешview GOYOJO SRG-1 Portable Roughness Tester User Manual
User manual for the GOYOJO SRG-1 Portable Roughness Tester, detailing its features, operation, technical specifications, maintenance, and data definitions.
Пешview GOYOJO GR Series Thermal Imaging Monocular Instruction Manual
Comprehensive instruction manual for GOYOJO GR225, GR235, GR325, GR335, and GR335L thermal imaging monoculars. Covers product operation, safety, maintenance, and features for outdoor thermal imaging applications.