Jaycar QC1938

Jaycar Digitech QC1938 100MHz Дастури истифодабарандаи осциллографи рақамӣ

1. Муқаддима

This manual provides detailed instructions for the safe and effective operation of your Jaycar Digitech QC1938 100MHz Digital Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. Retain this manual for future reference.

2. Маълумот оид ба бехатарӣ

Observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.

  • Манбаи нерӯ: Connect the oscilloscope only to the power source specified in this manual.
  • Ба заминканӣ: Боварӣ ҳосил кунед, ки дастгоҳ ба таври дуруст ба замин пайваст карда шудааст, то аз зарбаи барқ ​​​​пешгирӣ карда шавад.
  • Санҷишҳо: Use only probes supplied or recommended by the manufacturer. Ensure probes are rated for the voltagд чен карда мешавад.
  • Вентилятсия: Сӯрохиҳои вентилятсияро набандед. Дар атрофи дастгоҳ гардиши кофии ҳаворо таъмин кунед.
  • Муҳити зист: Operate the oscilloscope in a dry environment. Avoid exposure to moisture, dust, or extreme temperatures.
  • Хизматрасонӣ: Ҳамаи хизматрасониҳоро ба кормандони баландихтисос оид ба хизматрасонии техникӣ супоред. Кӯшиш накунед, ки асбобро худатон таъмир кунед.

3. Мундариҷаи баста

Боварӣ ҳосил кунед, ки ҳамаи ҷузъҳои дар поён овардашуда дар бастаи шумо мавҷуданд:

  • Jaycar Digitech QC1938 Digital Oscilloscope
  • 10:1 Passive Probe with 1.5m lead
  • 2 x BNC to Clip Test Leads
  • Сими USB
  • Пешвои барқ
  • Дастури корбар (ин ҳуҷҷат)

4. Маҳсулот ба охир расидview

The Jaycar Digitech QC1938 is a 100MHz Digital Oscilloscope designed for precise electronic measurements. It features a 7-inch color LCD screen, two independent channels, and a built-in waveform generator.

Пеш view of the Digitech QC1938 Digital Oscilloscope displaying a sine wave on its screen.
Расми 4.1: Пеш view of the Digitech QC1938 Digital Oscilloscope. This image shows the main display, control knobs, function buttons, and input connectors for channels 1 and 2, along with the USB port.
кунҷӣ view of the Digitech QC1938 Digital Oscilloscope, highlighting the side ventilation and handle.
Расми 4.2: кунҷӣ view of the Digitech QC1938 Digital Oscilloscope. This perspective emphasizes the robust build, integrated handle for portability, and side ventilation grilles.
кунҷӣ view of the Digitech QC1938 Digital Oscilloscope displaying a complex waveform.
Расми 4.3: Дигар кунҷӣ view of the Digitech QC1938 Digital Oscilloscope. The screen displays a different waveform, demonstrating the device's capability to visualize various signal types.

Хусусиятҳои асосӣ:

  • 7-inch TFT color LCD screen with 800 x 480 pixel resolution
  • Two independent input channels
  • 100MHz bandwidth and 1GSa/s sampсуръати давомнокӣ
  • 8M memory depth (single channel)
  • Integrated 25MHz waveform generator (Sine, Square, Ramp, Exponential, Noise, DC)
  • Auto scale function for automatic sine and square wave detection
  • 14 trigger modes including Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, and IIC
  • 5 serial protocol triggers and decodes: RS232/UART, I2C, SPI, CAN, and LIN
  • Two 3-digit digital voltmeters and a 6-digit hardware frequency indicator
  • 32 types of auto measurements with real-time statistics
  • USB Host/Device interface for computer control and data storage

5. Танзимот

5.1 Пайвастшавии барқ

  1. Connect the supplied power lead to the power input on the rear panel of the oscilloscope.
  2. Plug the other end of the power lead into a grounded AC power outlet.
  3. Барои фаъол кардани осциллограф тугмаи барқро дар панели пеш пахш кунед.

5.2 Пайвастшавии зонд

  1. Connect the BNC connector of the passive probe to either Channel 1 (CH1) or Channel 2 (CH2) input on the front panel.
  2. Attach the ground clip of the probe to the circuit's ground point.
  3. Connect the probe tip to the test point in your circuit.
  4. Ensure the probe's attenuation setting (e.g., 1X or 10X) matches the setting on the oscilloscope for accurate readings.

6. Дастурҳои истифодабарӣ

6.1 Амалиёти асосӣ

  • Auto Scale: Press the 'AUTO SET' button to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display. This function detects sine and square waves automatically.
  • Vertical Controls (VOLTS/DIV, POSITION): Use the VOLTS/DIV knobs to adjust the vertical scale (voltage per division) for each channel. The POSITION knobs shift the waveform vertically.
  • Horizontal Controls (SEC/DIV, POSITION): Use the SEC/DIV knob to adjust the horizontal scale (time per division). The horizontal POSITION knob shifts the waveform horizontally.
  • Сатҳи триггер: Adjust the 'TRIGGER LEVEL' knob to set the voltage level at which the oscilloscope captures a waveform.

6.2 Функсияҳои пешрафта

  • Генератор шакли мавҷ: Access the waveform generator menu to select and configure output waveforms such as Sine, Square, Ramp, Exponential, Noise, and DC. Connect the 'WAVE GEN' output to your circuit.
  • Усулҳои триггер: Utilize the 14 available trigger modes (Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC) to capture specific events. Select modes via the 'TRIGGER' menu.
  • Serial Protocol Decoding: The oscilloscope supports decoding for RS232/UART, I2C, SPI, CAN, and LIN protocols. Configure these settings in the 'DECODE' menu to view decoded data.
  • Андозаҳо: The device offers 32 types of automatic measurements with real-time statistics (maximum, minimum, standard deviation, etc.). Access these via the 'MEASURE' menu.
  • Пайвастшавӣ USB: Connect a USB thumb drive to the USB Host port to save oscilloscope setups, waveforms, reference waveforms, CSV files, and images. The USB Device port allows for remote control from a computer using SCPI commands.

7. Нигоҳдорӣ

7.1 Тозакунӣ

To clean the instrument, use a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.

7.2 Нигоҳдорӣ

When not in use, store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. Use the original packaging or a suitable case for protection during transport.

8. Баррасии мушкилот

If you encounter issues with your oscilloscope, refer to the following common problems and solutions:

МушкилотСабаби эҳтимолӣҲалли
Не қудратPower cable not connected; Power outlet faulty; Power button not pressedCheck power cable connection; Test power outlet; Press power button firmly
Шакли мавҷ нишон дода нашудаастProbe not connected; Incorrect input channel selected; Vertical/Horizontal scale incorrect; Trigger level too high/lowConnect probe to CH1/CH2; Select correct channel; Adjust VOLTS/DIV and SEC/DIV; Adjust TRIGGER LEVEL or use 'AUTO SET'
Шакли мавҷи ноустуворIncorrect trigger settings; No stable trigger sourceAdjust trigger level; Select appropriate trigger mode; Ensure a stable signal source
Диски USB шинохта нашудUSB drive formatted incorrectly; Drive not fully insertedEnsure USB drive is FAT32 formatted; Re-insert USB drive firmly

Агар пас аз кӯшиши ин ҳалли мушкилот мушкилот боқӣ монад, лутфан бо дастгирии муштариён тамос гиред.

9. Мушаххасоти

ПараметрМушаххасоти
Намоиш7 дюймаи TFT ранги LCD
Резолюция800 x 480 пиксел
Навъи намоишPoint, Vector
Каналҳо2
Маҷрои маҷрои100 МГц
SampLing RateТо 1 GSa/s
Амиқии хотира8M (single channel)
Диапазони амудӣ2mV / div ~ 10V / div
Қарори амудӣ8 бит
Генератори шакли мавҷСинус, Майдон, Рamp, Exponential, Noise, DC
ИнтерфейсUSB Host, USB Device
Вазн1.9 кг
Андозаҳо (L x H x W)318 мм х 150 мм х 110 мм

10. Кафолат ва дастгирӣ

Барои гирифтани маълумот дар бораи кафолат ва дастгирии техникӣ, лутфан ба ҳуҷҷатҳои ҳангоми харид пешниҳодшуда муроҷиат кунед ё бо фурӯшандаи худ тамос гиред. Барои даъвоҳои кафолат далели хариди худро нигоҳ доред.

Ҳуҷҷатҳои марбут - QC1938

Пешview Jaycar AA0378 Дастури барномасозии таймери барномарезишаванда
Ин дастур дар бораи барномасозии модули Jaycar AA0378 Timer Programmable, шарҳи вазифаҳои реле, танзимоти jumper ва пешниҳоди пештараи амалиро тафсилот медиҳад.amples барои муқаррар кардани давраҳои ON ва OFF.
Пешview Non-Contact Infrared Thermometer Operating Manual - Model QM7221
Operating manual for the QM7221 Non-Contact Infrared Thermometer, detailing features, specifications, operation, safety, and maintenance for accurate temperature measurements.
Пешview Дастури истифодабарии Ultrasonic Cleaner - YH5408
Дастури ҳамаҷонибаи корбар барои YH5408 Ultrasonic Cleaner, ки дастурҳои муҳими бехатарӣ, тавсифи қисмҳо, дастурҳои амалиёт, усулҳои тозакунӣ ва маслиҳатҳои нигоҳубинро дар бар мегирад.
Пешview Jaycar QC3150 Smart Ring дастури оғози зуд
Дастури мухтасар оид ба насб ва истифодаи ҳалқаи Smart Jaycar QC3150 бо қуттии пуркунандаи он. Дар бораи хусусиятҳо ва кори асосии он маълумот гиред.
Пешview XC3800 ESP32 Шӯрои асосӣ бо WiFi ва Bluetooth - Техникӣ ба охир расидview ва Танзимот
Маълумоти муфассал дар бораи XC3800 ESP32 Main Board, як микроконтроллери дугонаи дорои WiFi ва Bluetooth. Дастурҳои танзимотро барои муҳити таҳияи Arduino IDE ва MicroPython дар бар мегирад.
Пешview Jaycar TL4390 Mini Auto Vacuum Pump with 3D Filament Storage Bags User Manual
User manual for the Jaycar TL4390 Mini Auto Vacuum Pump, detailing its use with 3D filament storage bags. Includes setup, operation, and maintenance instructions.