1. Муқаддима
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity K1 Wood Stove. The Prity K1 is an economical and efficient solid fuel stove, designed to provide comfortable heating for your home. It is characterized by its robust construction, aesthetic design, and high thermal efficiency.
Key features include a reinforced combustion chamber with refractory bricks for heat accumulation, a heat-resistant ceramic glass door, a durable cast iron grate, and manual dampers for precise control over combustion. The stove also features an integrated compartment for wood storage.

Тасвири 1.1: Пеш view of the Prity K1 Wood Stove with a visible fire in the combustion chamber. The stove is black with a top flue connection and a lower storage compartment.
The Prity K1 Wood Stove has a nominal heat output of 9.5 kW and an efficiency of 77.8%, capable of heating an area of approximately 52 m². It operates using wood or coal as fuel.
2. Маълумот оид ба бехатарӣ
Please read all safety instructions carefully before installing or operating the stove. Failure to follow these instructions may result in property damage, personal injury, or death.
- Насби касбӣ: Installation must be performed by a qualified professional and comply with all local and national building and fire safety codes.
- Маводҳои сӯзишворӣ: Maintain minimum clearances to combustible materials.

Тасвири 2.1: Diagram illustrating the required safety distances from combustible materials for the Prity K1 Wood Stove. The distances are specified as 40 cm to the rear, 40 cm to the sides, and 80 cm to the front.
- Сӯзишворӣ: Only use recommended solid fuels (dry wood with moisture content ≤ 20%, or coal). Never use flammable liquids, trash, or treated wood.
- Вентилятсия: Ensure adequate ventilation in the room where the stove is installed to prevent carbon monoxide buildup.
- Назорат: Never leave the stove unattended while in operation. Keep children and pets away from the hot surfaces.
- Сатҳи гарм: The stove surfaces become very hot during operation. Use protective gloves when handling the stove or adding fuel.
- дудкаш: Ensure the chimney is clean and in good condition. Regular chimney sweeping is crucial to prevent creosote buildup and chimney fires.
- Хориҷ кардани хокистар: Хокистарро дар зарфи металлӣ бо сарпӯши маҳкам, дур аз маводҳои сӯзишвор партоед.
3. Танзим ва насб
The Prity K1 Wood Stove requires assembly. It is strongly recommended that installation be carried out by a certified professional to ensure compliance with all safety standards and optimal performance.
3.1 Кушодан ва тафтиш
- Carefully unpack the stove and all components.
- Inspect for any damage that may have occurred during transit. Contact your supplier immediately if any damage is found.
- Боварӣ ҳосил кунед, ки ҳамаи қисмҳои дар рӯйхати бастабандӣ номбаршуда мавҷуданд.
3.2 Ҷойгиркунӣ
- Place the stove on a non-combustible floor protector if the floor is combustible.
- Adhere strictly to the minimum clearances to combustible materials as specified in Section 2 (Rear: 40 cm, Sides: 40 cm, Front: 80 cm).
3.3 Пайвастшавӣ ба дудкаш
- The stove is designed for a top flue connection.
- The flue pipe diameter required is 130 mm.
- Ensure all flue pipe connections are sealed properly to prevent smoke leakage.
- The chimney system must be suitable for solid fuel appliances and meet local regulations.

Тасвири 3.1: Тараф view of the Prity K1 Wood Stove with overall dimensions labeled. The height is 76 cm, width is 38 cm, and depth is 45 cm.
4. Амалиёт
Operating your Prity K1 Wood Stove effectively involves proper fuel selection, ignition, and air control.
4.1 Сӯзишворӣ
- The Prity K1 is designed to burn dry wood (moisture content ≤ 20%) and coal.
- Using dry, seasoned wood ensures optimal heat output and minimizes creosote buildup.
- Avoid burning wet wood, treated wood, plastics, or household waste, as these can damage the stove, create excessive smoke, and pose health risks.
4.2 Сӯхтор
- Open both the front air supply damper and the smoke damper fully.
- Place crumpled paper or natural firelighters on the cast iron grate.
- Stack small pieces of kindling wood on top of the firelighters.
- Light the firelighters and close the combustion chamber door once the kindling is burning steadily.
- Gradually add larger pieces of wood as the fire establishes.
4.3 Назорати ҳаво
The stove is equipped with two manual dampers for regulating combustion:
- Front Air Supply Dampэ: Controls the primary air intake, which feeds oxygen to the base of the fire. Open for faster burning and higher heat, close partially for slower burning.
- Дуд Дampэ: Regulates the intensity of the flames and the draft through the chimney. Adjust to achieve optimal burning and prevent excessive heat loss up the chimney.
Танзими dampers to achieve a steady, bright flame. Too much air will cause the fuel to burn too quickly, while too little air will result in a smoldering fire, increased smoke, and creosote buildup.
5. Нигоҳдорӣ
Regular maintenance ensures the longevity and safe operation of your Prity K1 Wood Stove.
5.1 Тоза кардани хокистар
- Remove ashes regularly from the ash pan beneath the grate. Do not allow ash to build up and touch the bottom of the grate, as this can restrict airflow and damage the grate.
- Always ensure the stove is completely cool before removing ashes.
- Dispose of ashes in a non-combustible metal container with a lid, and store away from any flammable materials.
5.2 Cleaning the Combustion Chamber and Glass
- Periodically clean the interior of the combustion chamber to remove any soot or creosote buildup.
- The ceramic glass door can be cleaned with a specialized stove glass cleaner when the stove is cold. Avoid abrasive cleaners that could scratch the glass.
5.3 Chimney Cleaning
- The chimney and flue pipe should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type.
- This task should be performed by a certified chimney sweep to ensure safety and compliance.
5.4 Seals and Components
- Regularly inspect the door seals for wear and tear. Worn seals can lead to air leaks, reducing efficiency and potentially allowing smoke into the room. Replace seals as needed.
- Check the condition of the refractory bricks inside the combustion chamber. Replace any cracked or broken bricks to maintain efficiency and protect the stove body.
6. Баррасии мушкилот
This section addresses common issues you might encounter with your Prity K1 Wood Stove.
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Истеҳсоли гармии паст | Wet fuel, insufficient air, poor chimney draft, excessive ash buildup | Use dry fuel, open air dampers, check chimney for blockages, remove ash |
| Excessive smoke in room | Poor chimney draft, blocked flue, door seals worn, negative room pressure | Check chimney, clean flue, replace door seals, ensure adequate room ventilation |
| Оташ хеле зуд месузад | Too much air, door not sealed properly | Partially close air dampers, check and replace door seals |
| Шиша зуд сиёҳ мешавад | Wet fuel, insufficient air, low burning temperature | Use dry fuel, ensure adequate air supply, burn at higher temperatures |
7. Мушаххасоти
Detailed technical specifications for the Prity K1 Wood Stove.

Тасвири 7.1: English table detailing product information for the Prity K1, including fuel type, energy efficiency, heat output, flue gas temperature, and dimensions.
| Хусусият | Мушаххасоти |
|---|---|
| Бренд | Прити |
| Модели | K1 |
| Ранги | Графит сиёҳ |
| Андозаҳои маҳсулот (L x W x H) | 45 х 38 х 76 см |
| Combustion Chamber Dimensions (L x W x H) | 37 х 33.7 х 32 см |
| Вазни ашё | 61 кг |
| Баромади гармӣ | 9.5 кВт |
| Самаранокӣ | 77.8% |
| Синфи самаранокии энергия | A |
| Майдони гармидиҳӣ | тахминан. 52 м² |
| Диаметри қубури дуддодашуда | 130 мм |
| Мавқеи дудкаш | боло |
| Навъи сӯзишворӣ | Dry wood (≤ 20% moisture), Coal |
| Flue Gas Temperature at Nominal Heat Output | 326 °C |
| Minimum Chimney Draft | 11 Па |
| Истеъмоли сӯзишворӣ | 2.9 кг/соат |
| Материал | Steel, Ceramic Glass, Refractory Bricks |
| Маҷлис талаб карда мешавад | Бале |
| Рақами бақайдгирии EPREL | 1269866 (View ЭПРЕЛ) |
8. Кафолат ва дастгирӣ
For warranty information, spare parts, or technical support, please contact the manufacturer directly.
- Истеҳсолкунанда: Прити
- Webсайт: www.prity-bg.com
- Почтаи электронӣ: prity95@live.com
- Телефон: +359 884 941 948
- Мавҷудияти қисмҳои эҳтиётӣ: Information unavailable.




