SKINACT 164242

SKINACT Bellage Electric Treatment Table (Chair) User Manual

Модели: 164242

Муқаддима

This manual provides essential information for the safe and effective operation and maintenance of your SKINACT Bellage Electric Treatment Table. Please read this manual thoroughly before initial use and keep it for future reference.

The SKINACT Bellage Electric Treatment Table is a versatile, electrically adjustable chair designed for professional use in salons, spas, and medical offices. It features four independent motors for precise positioning of the backrest, leg rest, seat tilt, and overall height, ensuring optimal comfort for clients and ergonomic convenience for practitioners.

SKINACT Bellage Electric Treatment Table in beige, reclined position

Figure 1: SKINACT Bellage Electric Treatment Table (Beige)

Маълумот оид ба бехатарӣ

Adherence to these safety guidelines is crucial for preventing injury and damage to the equipment.

  • Do not use near water or in excessively damp муҳитҳо.
  • Аз дастрасии кӯдакон дур нигоҳ доред.
  • Avoid using harsh chemicals or abrasive cleaners on any part of the table.
  • Always unplug the device from the power outlet before performing any adjustments, cleaning, or maintenance.
  • Аз ҳадди ниҳоии вазни 300 фунт (136 кг) зиёд накунед.
  • Ensure all electrical connections are secure and undamaged before operation.
  • Do not operate the chair if any part is damaged or malfunctioning. Contact customer support immediately.

Ташкил кардан

The SKINACT Bellage Electric Treatment Table typically arrives pre-assembled or requires minimal assembly. Follow these general steps for initial setup:

  1. Carefully remove all packaging materials. Inspect the table for any signs of shipping damage.
  2. Place the table on a stable, level surface. Ensure adequate space around the table for full range of motion and safe operation.
  3. Connect the power cord to a grounded electrical outlet (100-120 volts, 50-60 hertz).
  4. Connect the wired remote control and any optional foot controls to their respective ports on the table's base.
  5. Adjust the leveling feet on the base to ensure the table is perfectly stable and does not wobble.
  6. Attach the desired headrest (with or without face hole) and armrests as needed.
Diagram showing electric adjustments and features of the Bellage chair

Figure 2: Key Features and Electric Adjustments

Дастурҳои амалиётӣ

The SKINACT Bellage Electric Treatment Table offers multiple points of adjustment for optimal client comfort and practitioner convenience. All adjustments are controlled via the wired remote control or optional foot controls.

Истифодаи пулти дурдаст

The wired remote control features intuitive buttons for each adjustable section of the chair. Familiarize yourself with the button layout:

  • Танзими баландӣ: Use the up/down arrows to raise or lower the entire table.
  • Кунҷи пушти пушти: Adjust the backrest from 0° to 80° incline.
  • Leg Rest Angle: Adjust the leg rest from 0° to 85° decline.
  • Seat Tilt Angle: Adjust the bed tilt angle from 0° to 10°.
Image of the wired remote control for the treatment table

Figure 3: Wired Remote Control

Adjusting Table Sections

  • Танзими қафо: Use the corresponding buttons on the remote to raise or lower the backrest.
    Close-up of the headrest without a face hole

    Figure 4: Headrest without Face Hole

  • Танзими истироҳати по: Use the corresponding buttons on the remote to adjust the leg rest angle. The leg rest also features an extension for added length.
    Diagram showing leg rest angle adjustment

    Figure 5: Leg Rest Adjustment

  • Танзими баландӣ: Use the remote to raise or lower the entire table to your desired working height.
    Diagram showing height adjustment of the treatment table

    Расми 6: Танзими баландии бадан

  • Armrest and Headrest Removal: Armrests and headrests are removable for versatility.
    Image showing how to remove the armrest

    Figure 7: Armrest Removal

    Image showing how to remove the headrest

    Figure 8: Headrest Removal

Нигоҳдорӣ

Proper maintenance ensures the longevity and optimal performance of your treatment table.

  • Тозакунӣ: Wipe the surface with a dry cloth. For deeper cleaning, use a mild, non-abrasive cleaner specifically designed for PU upholstery. Avoid harsh chemicals.
  • Санҷиш: Regularly inspect all moving parts, electrical cords, and connections for wear or damage.
  • Молидани: Moving parts may require periodic lubrication. Consult a qualified technician if you notice any stiffness or unusual noises during operation.
  • Нигоҳдорӣ: When not in use for extended periods, store the table in a clean, dry environment, away from direct sunlight and extreme temperatures.

Мушкилкушо

If you encounter issues with your SKINACT Bellage Electric Treatment Table, try these basic troubleshooting steps before contacting support:

  • Table Not Responding:
    • Check if the power cord is securely plugged into both the table and the wall outlet.
    • Боварӣ ҳосил кунед, ки васлаки деворӣ коршоям аст, онро бо дастгоҳи дигар санҷед.
    • Verify that the remote control and foot controls are properly connected.
  • Садоҳои ғайриоддӣ ҳангоми кор:
    • Ensure no objects are obstructing the moving parts of the table.
    • If noises persist, contact customer support; do not attempt to disassemble the motors.
  • Функсияи фосилавӣ:
    • Ҳамаи пайвастҳои кабелро аз рӯи сустӣ ё осеб тафтиш кунед.
    • Avoid overloading the table beyond its specified weight capacity.

Барои мушкилоте, ки бо ин қадамҳо ҳал нашудаанд, лутфан ба бахши Кафолат ва Дастгирӣ муроҷиат кунед.

Мушаххасоти

ХусусиятТафсилот
БрендSKINACT
Рақами модел164242
Андозаҳои ашё (L x W x H)68 x 28 x 32 инч
Length (with headrest)76.8 инч
Диапазони баландӣ25.5 - 31.5 инч
Width (with armrests)35.4 инч
Кунҷи пушти сар0° to 80° incline
Bed Tilt Angle0° то 10°
Leg Rest Angle0° to 85° decline
Андозаҳои асосӣ36" Л х 23" В
Талаботи қувваи барқ100-120 volts, 50-60 hertz, 200 watts, 2 amp
МатериалMetal frame, plastic cover, foam, PU upholstery
Вазни ашё200 фунт
Иқтидори максималӣ350 фунт стерлинг
РангиБеж
Кишвари аслӣХитой
Diagram showing detailed dimensions and maximum capacity of the treatment table

Figure 9: Detailed Dimensions and Capacity

Кафолат ва дастгирӣ

Your SKINACT Bellage Electric Treatment Table comes with a КАФОЛАТИ ЯК СОЛ covering manufacturing defects and malfunctions under normal use.

For warranty claims, technical assistance, or any questions regarding your product, please contact SKINACT Customer Support. You can find contact information on the official SKINACT webсайт ё тавассути платформаи хариди худ.

Additional protection plans may be available for purchase to extend coverage beyond the standard warranty period. Please refer to your purchase details for more information on available protection plans.

Ҳуҷҷатҳои марбут - 164242

Пешview Bellage Electric Treatment Table User Manual - SkinAct
User manual for the SkinAct Bellage Fully Electric 4 Motor Treatment Table (Chair), providing instructions, warnings, specifications, installation guide, controller usage, adjustments, and maintenance information.
Пешview SkinAct Rotating Treatment Tables Safety Information
Essential safety guidelines for operating SkinAct hydraulic and electric rotating facial beds and treatment tables, focusing on stability and client safety.
Пешview SkinAct Lusso IV Chair User Manual and Assembly Guide
Comprehensive user manual and assembly instructions for the SkinAct Lusso IV electric recliner chair. Learn how to assemble, operate, and maintain your Lusso IV chair.
Пешview SkinAct ARC LED Light Therapy Dome (SKU25538) User Manual and Guide
This document provides comprehensive instructions, safety guidelines, maintenance procedures, and technical specifications for the SkinAct ARC LED Light Therapy Dome (SKU25538), a professional beauty device.
Пешview Wavevia Head Spa Electric Massage Bed User Manual - SkinAct
Official user manual for the SkinAct Wavevia Head Spa Electric Massage Bed, providing safety instructions, installation guides, operating procedures, maintenance tips, and troubleshooting for optimal use.
Пешview SkinAct Steamer Caution and Operating Instructions