Thank you for choosing the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System. This unit is designed to provide efficient heating and cooling for residential, commercial, or hotel use. It features a built-in wireless smart kit for convenient control via smartphone, an included remote control, and comes with a wall sleeve for installation.

This manual provides essential information for the safe and effective setup, operation, and maintenance of your OLMO unit. Please read it thoroughly before installation and use.

OLMO Through-the-Wall Air Conditioner unit with remote control, smartphone app, and wall sleeve.

Figure 1: OLMO Through-the-Wall Air Conditioner and included accessories.

Насб ва насб

The OLMO Through-the-Wall Air Conditioner is designed for packaged installation. A wall sleeve is included with your unit to facilitate proper mounting.

Рӯйхати санҷиши пеш аз насб:

Wall Sleeve Installation:

The included wall sleeve (Model: OW-TTWSLV) is crucial for secure and proper installation. Follow the detailed instructions provided in the separate installation guide for precise measurements and mounting procedures. Proper sealing and insulation around the sleeve are essential for optimal performance and energy efficiency.

White metal wall sleeve for through-the-wall air conditioner.

Figure 2: Included Wall Sleeve (OW-TTWSLV).

Ҷойгиркунии воҳид:

Ensure the unit is installed in a location that allows for proper airflow around the intake and exhaust vents. Avoid placing objects directly in front of or on top of the unit that could obstruct air circulation.

Дастурҳои амалиётӣ

Your OLMO Through-the-Wall unit offers multiple control options for your convenience:

Функсияҳои идоракунии дурдаст:

The remote control allows you to adjust temperature, change modes (Cool, Heat, Fan, Dry, Auto), set fan speeds, and activate special features like Sleep Mode and Timer.

White remote control for OLMO air conditioner with various buttons for mode, fan speed, temperature, and timer.

Figure 3: Remote Control for OLMO AC Unit.

Smart Connect (Wi-Fi) Operation:

The built-in Smart Connect feature enables you to control your unit remotely using a smartphone app. Download the official OLMO app from your device's app store and follow the in-app instructions to pair your unit. This allows for convenient control from anywhere with an internet connection.

A hand holding a smartphone displaying the OLMO air conditioner control app interface.

Figure 4: Smartphone App for Smart Control.

Хусусиятҳои асосӣ:

Видео: Ба охир расидview of OLMO Through-the-Wall Air Conditioner features and capabilities. This video demonstrates the unit's design and highlights its smart connectivity and remote control options.

Нигоҳдорӣ

Regular maintenance ensures optimal performance and longevity of your OLMO air conditioner. Always disconnect power to the unit before performing any maintenance.

Тоза кардани филтри ҳаво:

The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. A dirty filter can reduce cooling/heating efficiency and airflow.

  1. Панели пеши дастгоҳро кушоед.
  2. Carefully remove the air filter(s).
  3. Филтрро бо оби гарм ва собун бишӯед. Бодиққат бишӯед.
  4. Allow the filter to air dry completely before reinserting. Do not expose to direct sunlight or heat.

Тозакунии умумӣ:

берунии агрегатро бо нарм пок кунед, гamp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure the drainage area is clear of debris.

Мушкилкушо

If you experience issues with your OLMO air conditioner, refer to the following common troubleshooting steps. For problems not listed here, or if issues persist, please contact OLMO customer support.

МушкилотСабаби эҳтимолӣҲалли
Дастгоҳ фурӯзон намешавадNo power supply; Circuit breaker tripped; Unit unplugged.Check power cord connection; Reset circuit breaker; Ensure unit is plugged into a functional 115V outlet.
хунуккунӣ/гармкунии нокифояDirty air filter; Obstructed airflow; Temperature setting too high/low; Room size exceeds capacity.Clean air filter; Remove obstructions from vents; Adjust temperature setting; Ensure unit capacity matches room size.
Воҳиди садо баланд астҚисмҳои фуҷур; Дастгоҳ ҳамвор нест; Басташавии вентилятор.Check for loose components; Ensure unit is level; Inspect fan for obstructions.
Правленияи дурдаст кор намекунадбатареяҳои мурда; Монеа байни дурдаст ва дастгоҳ.Батареяҳоро иваз кунед; Боварӣ ҳосил кунед, ки қабулкунаки дастгоҳ ба таври равшан намоён аст.

Мушаххасоти

Detailed technical specifications for the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System (Model: OW-P08HS115WF/ OW-TTWSLV).

МушаххасотиАрзиш
Номи брендЭЛМ
Маълумоти моделиOW-P08HS115WF/ OW-TTWSLV
Вазни ашё80 фунт
Андозаҳои маҳсулот (D x W x H)20.28 x 24.21 x 14.53 инч
Кишвари аслӣХитой
СамаранокӣХуб
Иқтидор0.66 тонна
Сатҳи садо52 дБ
Навъи насбPackaged, Through-the-Wall
Хусусиятҳои махсусНазорати дурдаст, WiFi фаъол
Унсурҳои гармидиҳӣ1
РангиСафед
Ҷилдиtage115 вольт
Компонентҳои дохилшудаThrough the Wall Air Conditioner, Wall Sleeve and Remote Control
Қувваи хунуккунӣ8000 воҳидҳои гармидиҳии Бритониё
яхдонR-32
Detailed technical specifications table for various OLMO Through-the-Wall AC models, including power, capacity, EER, current, noise, and dimensions.

Figure 5: Comprehensive Technical Specifications Table.

Кафолат ва дастгирӣ

For technical assistance, warranty inquiries, or further support, please contact OLMO customer service. Refer to your product packaging or the official OLMO webсайт барои маълумоти охирини тамос.

You can also visit the official OLMO store for more product information and resources: OLMO Store on Amazon.

Ҳуҷҷатҳои марбут - OW-P08HS115WF/ OW-TTWSLV

Пешview OLMO Through The Wall Air Conditioner Service Manual - Models OW-08, OW-12, OW-14
Comprehensive service manual for OLMO through-the-wall air conditioners (models OW-08HS115V6TW, OW-08AC115V5SC, OW-12AC115V5SC, OW-12HS230V6TW, OW-12AC230V5SC, OW-14HS230V6TW, OW-14AC230V5SC). Covers operation, electronic functions, troubleshooting, installation, and parts.
Пешview OLMO Air Conditioning Systems: Sierra Series Mini-Splits, Through-the-Wall, and PTAC Units
Explore OLMO's range of energy-efficient air conditioning solutions, including Inverter Technology mini-split systems (Sierra Series), Through-the-Wall AC, and Packaged Terminal Air Conditioners (PTAC). Find detailed specifications, features, and product information.
Пешview OLMO Split Air Conditioner with Heat Pump User's Manual
Comprehensive user manual for the OLMO Split Air Conditioner with Heat Pump, covering safety precautions, unit specifications, features, care and maintenance, and troubleshooting.
Пешview OLMO Wall Mounted Mini Split Air Conditioning System: Use and Installation Manual
Comprehensive use and installation manual for OLMO Multi-Sierra wall-mounted mini-split air conditioning systems, covering models OS-RM09SW-230VI, OS-RM12SW-230VI, OS-RM18SW-230VI, and OS-RM24SW-230VI. Provides essential information for operation and setup.
Пешview OLMO Split Air Conditioner with Heat Pump User's Manual
Comprehensive user manual for the OLMO Split Air Conditioner with Heat Pump, covering operation, maintenance, safety precautions, and troubleshooting. Includes detailed instructions and specifications.
Пешview OLMO OS-EAH36-230VO Installation Manual for Central Split Air Handler Outdoor Unit
Get detailed installation instructions for the OLMO OS-EAH36-230VO multi-position AHU outdoor unit. This manual covers safety, setup, wiring, and testing for central split air conditioning systems.