Муқаддима
Thank you for choosing the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System. This unit is designed to provide efficient heating and cooling for residential, commercial, or hotel use. It features a built-in wireless smart kit for convenient control via smartphone, an included remote control, and comes with a wall sleeve for installation.
This manual provides essential information for the safe and effective setup, operation, and maintenance of your OLMO unit. Please read it thoroughly before installation and use.
Figure 1: OLMO Through-the-Wall Air Conditioner and included accessories.
Насб ва насб
The OLMO Through-the-Wall Air Conditioner is designed for packaged installation. A wall sleeve is included with your unit to facilitate proper mounting.
Рӯйхати санҷиши пеш аз насб:
- Verify power supply: This unit requires a 115V, 1-phase, 60Hz power supply. Ensure you have the correct receptacle.
- Check dimensions: The product dimensions are approximately 20.28 x 24.21 x 14.53 inches. Ensure your wall opening is appropriately sized for the unit and wall sleeve.
- Confirm refrigerant: The unit is pre-charged with R-32 refrigerant.
Wall Sleeve Installation:
The included wall sleeve (Model: OW-TTWSLV) is crucial for secure and proper installation. Follow the detailed instructions provided in the separate installation guide for precise measurements and mounting procedures. Proper sealing and insulation around the sleeve are essential for optimal performance and energy efficiency.

Figure 2: Included Wall Sleeve (OW-TTWSLV).
Ҷойгиркунии воҳид:
Ensure the unit is installed in a location that allows for proper airflow around the intake and exhaust vents. Avoid placing objects directly in front of or on top of the unit that could obstruct air circulation.
Дастурҳои амалиётӣ
Your OLMO Through-the-Wall unit offers multiple control options for your convenience:
- Digital Push Button Control Panel: Located on the unit with an LED display for direct control.
- Included Remote Controller: Provides full functionality from a distance.
- Built-In Wireless Smart Kit: Allows control via a compatible smartphone application.
Функсияҳои идоракунии дурдаст:
The remote control allows you to adjust temperature, change modes (Cool, Heat, Fan, Dry, Auto), set fan speeds, and activate special features like Sleep Mode and Timer.

Figure 3: Remote Control for OLMO AC Unit.
Smart Connect (Wi-Fi) Operation:
The built-in Smart Connect feature enables you to control your unit remotely using a smartphone app. Download the official OLMO app from your device's app store and follow the in-app instructions to pair your unit. This allows for convenient control from anywhere with an internet connection.

Figure 4: Smartphone App for Smart Control.
Хусусиятҳои асосӣ:
- Ҳолати хоб: Ҳароратро ба таври худкор барои хоби бароҳат ва сарфаи энергия танзим мекунад.
- Бозоғозии худкор: Пас аз хомӯш кардани барқ, дастгоҳ ба таври худкор бо танзимоти қаблӣ аз нав оғоз мешавадtage.
- Суръати якчанд мухлиси: Choose from various fan speeds for customized airflow.
- Вақтсанҷ: Дастгоҳро барномарезӣ кунед, то дар вақти муайян фурӯзон ё хомӯш шавад.
- Self-Evaporative System: Helps manage condensate, reducing the need for manual draining in most conditions.
- Намоиши LED: Provides clear indication of settings and operating status.
- Fresh Air Input: Allows for introduction of fresh outdoor air.
Видео: Ба охир расидview of OLMO Through-the-Wall Air Conditioner features and capabilities. This video demonstrates the unit's design and highlights its smart connectivity and remote control options.
Нигоҳдорӣ
Regular maintenance ensures optimal performance and longevity of your OLMO air conditioner. Always disconnect power to the unit before performing any maintenance.
Тоза кардани филтри ҳаво:
The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. A dirty filter can reduce cooling/heating efficiency and airflow.
- Панели пеши дастгоҳро кушоед.
- Carefully remove the air filter(s).
- Филтрро бо оби гарм ва собун бишӯед. Бодиққат бишӯед.
- Allow the filter to air dry completely before reinserting. Do not expose to direct sunlight or heat.
Тозакунии умумӣ:
берунии агрегатро бо нарм пок кунед, гamp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure the drainage area is clear of debris.
Мушкилкушо
If you experience issues with your OLMO air conditioner, refer to the following common troubleshooting steps. For problems not listed here, or if issues persist, please contact OLMO customer support.
| Мушкилот | Сабаби эҳтимолӣ | Ҳалли |
|---|---|---|
| Дастгоҳ фурӯзон намешавад | No power supply; Circuit breaker tripped; Unit unplugged. | Check power cord connection; Reset circuit breaker; Ensure unit is plugged into a functional 115V outlet. |
| хунуккунӣ/гармкунии нокифоя | Dirty air filter; Obstructed airflow; Temperature setting too high/low; Room size exceeds capacity. | Clean air filter; Remove obstructions from vents; Adjust temperature setting; Ensure unit capacity matches room size. |
| Воҳиди садо баланд аст | Қисмҳои фуҷур; Дастгоҳ ҳамвор нест; Басташавии вентилятор. | Check for loose components; Ensure unit is level; Inspect fan for obstructions. |
| Правленияи дурдаст кор намекунад | батареяҳои мурда; Монеа байни дурдаст ва дастгоҳ. | Батареяҳоро иваз кунед; Боварӣ ҳосил кунед, ки қабулкунаки дастгоҳ ба таври равшан намоён аст. |
Мушаххасоти
Detailed technical specifications for the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System (Model: OW-P08HS115WF/ OW-TTWSLV).
| Мушаххасоти | Арзиш |
|---|---|
| Номи бренд | ЭЛМ |
| Маълумоти модели | OW-P08HS115WF/ OW-TTWSLV |
| Вазни ашё | 80 фунт |
| Андозаҳои маҳсулот (D x W x H) | 20.28 x 24.21 x 14.53 инч |
| Кишвари аслӣ | Хитой |
| Самаранокӣ | Хуб |
| Иқтидор | 0.66 тонна |
| Сатҳи садо | 52 дБ |
| Навъи насб | Packaged, Through-the-Wall |
| Хусусиятҳои махсус | Назорати дурдаст, WiFi фаъол |
| Унсурҳои гармидиҳӣ | 1 |
| Ранги | Сафед |
| Ҷилдиtage | 115 вольт |
| Компонентҳои дохилшуда | Through the Wall Air Conditioner, Wall Sleeve and Remote Control |
| Қувваи хунуккунӣ | 8000 воҳидҳои гармидиҳии Бритониё |
| яхдон | R-32 |

Figure 5: Comprehensive Technical Specifications Table.
Кафолат ва дастгирӣ
For technical assistance, warranty inquiries, or further support, please contact OLMO customer service. Refer to your product packaging or the official OLMO webсайт барои маълумоти охирини тамос.
You can also visit the official OLMO store for more product information and resources: OLMO Store on Amazon.