Vertiv VP5N31A0

Vertiv Geist Switched Rack PDU User Manual

Model: VP5N31A0

1. Муқаддима

The Vertiv Geist Switched Rack PDU (Power Distribution Unit) model VP5N31A0 is designed to provide reliable power distribution and advanced power management capabilities within data centers and IT environments. This 1U horizontal PDU features input power monitoring and individual outlet switching, allowing for remote control and optimization of connected equipment. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your PDU.

2. Хусусиятҳои асосӣ

  • Нуқтаҳои ивазшаванда: Remotely turn off individual NEMA 5-20R receptacles to prevent accidental overloads or power cycle unresponsive IT equipment.
  • Input Power Monitoring: Monitor power consumption at the PDU level to optimize energy usage and capacity planning.
  • Next-Generation Interchangeable Monitoring Device (IMD): Features a 128x128 high-contrast LCD for clear display of power data. The IMD includes an internal sensor that automatically adjusts screen orientation for horizontal or vertical installations.
  • Амнияти мукаммал: Incorporates secure boot with a hardware-based trust anchor to protect data and operations.
  • Redundant Power-Sharing Port: Allows connection of two IMDs for backup power to the monitoring device in case of primary power loss.
  • Сертификатсияҳои саноатӣ: UL Listed, TAA-Compliant, and RoHS certified, ensuring compliance with industry standards.
  • Эътимоднокӣ: Each unit undergoes individual testing for functionality and reliability.

3. Танзим ва насб

3.1 Кушодан ва тафтиш

Carefully unpack the PDU and inspect it for any signs of shipping damage. Report any damage to your supplier immediately. Ensure all components listed in the packing slip are present.

3.2 Васлкунии раф

The VP5N31A0 is a 1U horizontal rack-mount unit. Install the PDU into a standard 19-inch equipment rack using the provided mounting hardware. Ensure adequate airflow around the unit for proper heat dissipation.

3.3 Пайвастшавии барқ

  1. Connect the PDU's NEMA L5-30P input plug to a compatible 30A, 120V power source.
  2. Ensure the power source is properly grounded and capable of supplying the required 2.8kW capacity.
  3. Verify that the power cable is securely connected and routed to prevent accidental disconnection or damage.

3.4 Таҷҳизоти пайвастшавӣ

Plug your IT equipment into the (12) NEMA 5-20R receptacles on the PDU. Distribute the load evenly across the outlets to avoid overloading any single circuit or the PDU itself.

3.5 Пайвастшавии шабака (ихтиёрӣ)

For remote monitoring and control, connect the PDU's network port to your network infrastructure using a standard Ethernet cable. Refer to the IMD documentation for network configuration details.

4. Дастурҳои истифодабарӣ

4.1 Interchangeable Monitoring Device (IMD)

The IMD provides real-time power data and access to PDU settings. The 128x128 high-contrast LCD displays information such as total power consumption (W), energy usage (KWh), apparent power (VA), and power factor (PF).

Аз наздики view of the Vertiv Geist PDU's Interchangeable Monitoring Device (IMD) display, showing power readings and navigation buttons.

Figure 1: Close-up of the IMD display showing power metrics.

4.2 Remote Outlet Switching

The switched outlets allow for remote control of power to connected devices. This functionality is typically accessed via a web interface or network management system connected to the PDU's network port. Consult the PDU's network management guide for detailed instructions on configuring and using remote outlet control.

4.3 Power Cycling Equipment

In situations where IT equipment becomes unresponsive, the remote outlet switching feature can be used to power cycle individual devices without requiring physical access to the rack. This helps minimize downtime and streamline maintenance.

5. Нигоҳдорӣ

5.1 Нигоҳубини умумӣ

Keep the PDU and its surroundings clean and free from dust. Ensure that ventilation openings are not obstructed. Do not use liquid or aerosol cleaners directly on the unit.

5.2 Навсозии нармафзор

Periodically check the Vertiv support website for available firmware updates for your PDU's IMD. Firmware updates can provide new features, performance improvements, and security enhancements. Follow the instructions provided with the firmware update package carefully.

6. Баррасии мушкилот

  • No Power to Outlets: Verify the PDU's input power cable is securely connected to a live power source. Check the circuit breaker on the PDU (if applicable) and the upstream circuit breaker.
  • IMD Display Not Active: Ensure the PDU is receiving power. If the IMD is modular, verify it is correctly seated.
  • Cannot Access PDU Remotely: Check network cable connections. Verify network settings (IP address, subnet mask, gateway) on the PDU and your network. Ensure there are no firewall restrictions.
  • Нишондиҳандаи изофабори: If the PDU indicates an overload, immediately reduce the connected load. Use the remote switching feature to turn off non-critical devices.
  • Unresponsive Equipment: Utilize the remote outlet switching feature to power cycle the specific unresponsive device.

7. Мушаххасоти

Рақами моделVP5N31A0
Формаи формаВаслкунии рафи уфуқии 1U
Вуруди ҷилдиtage120 вольт
Вуруд Ampнест кардан30 Amps
Иқтидори барқ2.8 кВт (2800 Ватт)
Васлкунаки воридотӣНЕМА L5-30P
Қуттиҳои баромад(12) NEMA 5-20R
Вазни ашё18.4 фунт
Андозаҳои бастаҳо24 x 24 x 6 инч
ИстеҳсолкунандаВертив
ASINB0DHMLBGHV
UPC767041044812

8. Кафолат ва дастгирӣ

8.1 Кафолати маҳсулот

The Vertiv Geist Switched Rack PDU VP5N31A0 comes with a standard three-year warranty. This warranty can be extended to five years if the unit is registered within 120 days of purchase. Refer to the official Vertiv webсайт барои шартҳои кафолат пурра.

8.2 Дастгирии техникӣ

For technical assistance, troubleshooting, or inquiries regarding your Vertiv product, please visit the official Vertiv support website or contact their customer service. Have your product model number (VP5N31A0) and serial number ready when contacting support.

Ҳуҷҷатҳои марбут - VP5N31A0

Пешview Geist™ Intelligent Rack PDU Installer/User Guide - Vertiv
Comprehensive installer and user guide for Vertiv's Geist™ Intelligent Rack PDU, covering installation, setup, network configuration, and advanced features for data center environments.
Пешview Насбкунандаи/Дастури корбарии Vertiv SmartRow 2 Ҳалли Инфрасохторӣ
Ин дастури мукаммал дастурҳои муфассалро оид ба насб, истифода ва нигоҳдории Vertiv SmartRow 2 Infrastructure Solution пешниҳод мекунад. Он системаро фаро мегирад.view, хусусиятҳо, дастурҳои бехатарӣ, идоракунии барқ, танзимоти шабака ва ҳалли мушкилот.
Пешview Avocent DSView ва Васлкунакҳои нармафзори Rack Power Manager: Бюллетени техникӣ
Ин бюллетени техникии Vertiv роҳнамоии ҳамаҷониба оид ба истифодаи Avocent DS медиҳадView ва плагинҳои нармафзори Rack Power Manager. Ин воситаҳо қобилиятҳои идоракунии инфрасохтори IT-ро такмил медиҳанд ва ба корбарон имкон медиҳанд, ки ба як қатор дастгоҳҳо, аз ҷумла PDUs, UPSҳо, серверҳои консолӣ ва муҳити виртуализатсия самаранок дастрасӣ, назорат ва назорат кунанд.
Пешview Дастури насбкунанда/корбар Vertiv Geist Watchdog 100
Дастури мукаммал оид ба насб ва истифодаи монитори экологӣ Vertiv Geist Watchdog 100, ки танзимот, конфигуратсияи шабакаро дар бар мегирад. web интерфейс, сенсорҳо, ҳушдорҳо ва маълумоти бехатарӣ.
Пешview Vertiv Liebert Mini-Mate Variable Capacity Condensing Unit Installer/User Guide
Comprehensive installer and user guide for the Vertiv Liebert Mini-Mate Variable Capacity Indoor Condensing Unit, covering installation, operation, maintenance, and safety for water/glycol-cooled and air-cooled models.
Пешview Avocent MergePoint Unity Quick Installation Guide
This guide provides step-by-step instructions for installing the Avocent MergePoint Unity KVM over IP and serial console switch, including connecting local ports, IQ modules, target devices, network users, and optional modems or PDUs.