HONGFA HF2160-1A-12DE, HF2160-1A-24DE

HONGFA HF2160-1A-12DE and HF2160-1A-24DE Relay Instruction Manual

For Water Heaters and Air Conditioners

1. Муқаддима

This manual provides essential information for the safe and effective use of HONGFA HF2160-1A-12DE and HF2160-1A-24DE relays. These relays are designed for switching electrical circuits in various applications, including water heaters and air conditioners. Please read this manual thoroughly before installation and operation.

2. Маҳсулот ба охир расидview

The HONGFA HF2160 series relays are single-pole, single-throw (SPST) power relays. They are designed for high current switching applications. The HF2160-1A-12DE operates with a 12V DC coil, while the HF2160-1A-24DE operates with a 24V DC coil. Both models feature robust construction suitable for demanding environments.

HONGFA HF2160-1A-12DE Relay

Расми 1: Пеш view of a single HONGFA HF2160-1A-12DE relay, showing the coil voltage and contact ratings printed on the casing.

Two HONGFA HF2160-1A-12DE Relays

Figure 2: Two HONGFA HF2160-1A-12DE relays side-by-side, illustrating their compact form factor.

Поён view of HONGFA HF2160-1A-12DE Relay terminals

Расми 3: Поён view of the HONGFA HF2160-1A-12DE relay, showing the pin configuration for electrical connections.

3. Мушаххасоти

ХусусиятТафсилот
Рақамҳои намунавӣHF2160-1A-12DE (12V Coil), HF2160-1A-24DE (24V Coil)
Шакли тамос1 Form A (SPST-NO)
Рейтинги тамос30A 240VAC, 30A 125VAC, 15A 250V~ (cosθ=0.4)
Coil Voltage12V DC (HF2160-1A-12DE), 24V DC (HF2160-1A-24DE)
ИстеҳсолкунандаGMGNUBRL (for this product listing)
Андозаҳои бастаҳо1.18 x 0.79 x 0.39 инч
ВазнApproximately 1.76 ounces per relay

4. Маълумот оид ба бехатарӣ

ОГОҲӢ: Хатари зарбаи барқ. Насб ва хидматрасонӣ бояд танҳо аз ҷониби кормандони соҳибихтисос анҷом дода шавад.

  • Always disconnect power to the circuit before installing, removing, or servicing the relay.
  • Ҳаҷми релеро таъмин кунедtage and current ratings match or exceed the requirements of your application.
  • Do not exceed the specified contact ratings. Overloading can cause damage to the relay and create a fire hazard.
  • Protect the relay from moisture, dust, and extreme temperatures.
  • Verify proper wiring connections to prevent short circuits or malfunction.

5. Насбкунӣ

Relays are critical components in electrical systems. Incorrect installation can lead to equipment damage or personal injury. It is strongly recommended that installation be performed by a certified electrician or a qualified technician.

5.1 Санҷишҳои пеш аз насб

  1. Confirm the relay model (HF2160-1A-12DE or HF2160-1A-24DE) matches the required coil voltage of your control circuit (12V DC or 24V DC).
  2. Verify that the contact ratings (30A 240VAC, 30A 125VAC) are sufficient for the load being switched.
  3. Inspect the relay for any physical damage. Do not install a damaged relay.

5.2 Дастурҳо оид ба васлкунӣ

The HF2160 series relays typically feature two coil terminals and two contact terminals (one common, one normally open). Refer to the diagram on the relay casing or the application's wiring schematic for precise connections.

  • Ҷилди назоратро пайваст кунедtage (12V DC or 24V DC) to the coil terminals. Ensure correct polarity if indicated.
  • Connect the load circuit to the contact terminals. The load should be connected between the power source and the normally open (NO) contact, with the common (COM) terminal connected to the power source or load return, depending on the circuit design.
  • Secure all connections firmly to prevent loose contacts, which can cause overheating or intermittent operation.

6. Амалиёт

The HONGFA HF2160 series relay operates by energizing its coil. When the specified coil voltage (12V DC or 24V DC) is applied to the coil terminals, an electromagnetic field is generated, which pulls the armature and closes the normally open (NO) contacts. This action completes the circuit for the connected load, allowing current to flow.

  • When the coil is energized, the relay contacts close, turning on the connected device (e.g., heating element, compressor).
  • When the coil is de-energized (voltage removed), the electromagnetic field collapses, and a spring returns the contacts to their normally open position, breaking the circuit and turning off the connected device.

7. Нигоҳдорӣ

HONGFA HF2160 series relays are generally maintenance-free under normal operating conditions. However, periodic inspection can help ensure long-term reliability.

  • Санҷиши визуалӣ: Periodically check the relay for signs of overheating (discoloration), physical damage, or loose connections.
  • Шароити экологӣ: Ensure the operating environment remains within the specified temperature and humidity ranges. Excessive dust or moisture can affect performance.
  • Тозакунӣ: If necessary, gently clean the exterior of the relay with a dry, soft cloth. Do not use solvents or abrasive cleaners.

8. Баррасии мушкилот

If the relay is not functioning as expected, consider the following common issues:

МушкилотСабаби эҳтимолӣҲалли
Relay does not switch (no click sound)No coil voltage, incorrect coil voltage, open coil, incorrect wiring.Check control circuit power supply. Verify coil voltage matches relay specification (12V or 24V). Inspect coil wiring for breaks or loose connections. Test coil resistance with a multimeter.
Relay switches but load does not turn onFaulty contacts, open load circuit, incorrect load wiring, overloaded contacts.Check load circuit for power and continuity. Verify load wiring. Ensure load current does not exceed relay contact rating. Replace relay if contacts are visibly damaged or not making proper connection.
Реле аз ҳад зиёд гарм мешавадOverloaded contacts, high ambient temperature, poor ventilation, continuous operation at maximum rating.Reduce load current if exceeding rating. Improve ventilation around the relay. Consider a relay with higher current capacity if continuous operation at maximum rating is required.
Амалиёти фосилавӣLoose connections, fluctuating control voltage, worn contacts.Tighten all wiring connections. Stabilize control voltage. Replace relay if contacts are worn.

If troubleshooting steps do not resolve the issue, consult a qualified technician.

9. Кафолат ва дастгирӣ

Specific warranty information for the HONGFA HF2160-1A-12DE and HF2160-1A-24DE relays is not provided in this manual. For warranty details, technical support, or further assistance, please contact the manufacturer or your point of purchase. Ensure you have your purchase details and the relay's model number available when contacting support.

Manufacturer: GMGNUBRL

Ҳуҷҷатҳои марбут - HF2160-1A-12DE, HF2160-1A-24DE

Пешview Hongfa UEC1 Series AC Contactors: Product Catalog and Technical Specifications
Comprehensive catalog detailing Hongfa's UEC1 series AC contactors, including product overview, technical characteristics, ordering information, electrical durability, accessories, and installation dimensions.
Пешview Xiamen Hongfa BCM (Body Control Module) User Manual - HF3758/12
Official user manual for the Xiamen Hongfa Body Control Module (BCM), model HF3758/12. Details system overview, parameters, functions, and appearance of the automotive electronic component.
Пешview Hongfa KEY FOB User Manual - System Overview, Parameters, and Functions
Comprehensive user manual for the Hongfa KEY FOB, detailing system overview, technical parameters, system functions, physical appearance, product information, and regulatory compliance statements (FCC, IC).
Пешview Hongfa HF46F Subminiature Intermediate Power Relay Datasheet
Technical specifications and characteristics for the Hongfa HF46F subminiature intermediate power relay, including contact data, coil data, safety approval ratings, and characteristic curves.
Пешview Hongfa HF7520 Subminiature Power Relay Datasheet
Technical specifications, ordering information, dimensions, and characteristic curves for the Hongfa HF7520 subminiature power relay, a high-performance component for various applications.
Пешview Hongfa HFV9-G Automotive Relay Datasheet and Specifications
Detailed specifications, features, applications, electrical characteristics, ordering information, and dimensions for the Hongfa HFV9-G Automotive Relay. Includes technical data, performance curves, and ordering codes.