GEYA GRT6-B2

Дастури корбарии релеи вақти хомӯшкунии таъхир GEYA GRT6-B2 10A

Electronic Type Adjustable Delay Timer 2NO2NC DIN Rail (AC/DC 24V-240V)

1. Маҳсулот ба охир расидview

The GEYA GRT6-B2 is an electronic delay off time relay designed for industrial and domestic applications. It features adjustable delay settings and is suitable for DIN rail mounting. This manual provides essential information for safe installation, operation, and maintenance.

Хусусиятҳои асосӣ:

  • Adjustable Delay: Delay can be set directly via panel knobs for convenience and intuitive control.
  • Усулҳои функсионалӣ: Supports two primary functions: Delay ON (A) and Delay OFF (B). The GRT6-B2 model features 2SPDT (2NO2NC) contacts.
  • Вақти васеъ: Time scale from 0.1 seconds to 10 days, divided into 10 selectable ranges.
  • Нишондиҳандаи ҳолати: Equipped with LED indicators for power (green light) and working status (red light).
  • Тарҳрезии компакт: Ultra-small size, only 18mm width, designed for 35mm DIN rail mounting.
GEYA GRT6-B2 Delay Off Time Relay front view
Расми 1: Пеш view of the GEYA GRT6-B2 Delay Off Time Relay, showing control knobs and terminals.

2. Маълумот оид ба бехатарӣ

Please read this manual carefully before installation and operation. Failure to follow these instructions may result in equipment damage, injury, or death. This device should only be installed and serviced by qualified personnel.

  • Пеш аз насб кардан, васл кардан ё нигоҳдорӣ дар дастгоҳ ҳамеша барқро ҷудо кунед.
  • Боварӣ ҳосил кунед, ки ҳамаи ноқилҳо ба кодексҳои барқии маҳаллӣ ва миллӣ мувофиқат мекунанд.
  • Do not operate the device if it is damaged or malfunctioning.
  • Дастгоҳро аз намӣ, чанг ва ҳарорати аз ҳад зиёд муҳофизат кунед.
  • Тасдиқи ҷилди дурустtage and current ratings before connecting to a power source.

3. Product Dimensions and Components

The GRT6-B2 relay is designed for compact installation on a DIN rail. Understanding its dimensions and component layout is crucial for proper integration into your system.

GEYA GRT6-B2 Delay Off Time Relay dimensions
Figure 2: Detailed dimensions of the GRT6-B2 relay in millimeters. The device measures 18mm in width, 95mm in height, and 64mm in depth.
GEYA GRT6-A1 and GRT6-B1 model comparison
Расми 3: Зиёдview of different GRT6 models, highlighting common components such as trigger terminal, supply terminal, LED indication, time range selection, time percentage setting, model number, and output contacts.

4. Монтаж ва кабелӣ

The GEYA GRT6-B2 relay is designed for easy installation on a 35mm DIN rail. Follow these steps for secure mounting and correct electrical connections.

4.1 Васлкунии роҳи оҳани DIN

The relay snaps onto a standard 35mm DIN rail. Ensure it is securely fastened to prevent movement during operation.

4.2 Ноқилҳои барқ

Refer to the wiring diagrams below for proper connection of the power supply and load. Always ensure power is disconnected before wiring.

GEYA GRT6-A1/B1 and GRT6-A2/B2 wiring diagrams
Figure 4: Wiring diagrams for GRT6-A1/B1 (1SPDT) and GRT6-A2/B2 (2SPDT) models. Connect L (Line) and N (Neutral) to A1 and A2 respectively for power supply. Output contacts are typically 15, 16, 18 for 1SPDT and 15, 16, 18 and 25, 26, 28 for 2SPDT.

4.3 Power Connection Demonstration

Watch this video for a visual guide on connecting power and load to the GRT6-B1 model, which shares similar wiring principles with the GRT6-B2.

Video 1: Demonstration of power connection and load access for a GEYA GRT6-B1 time relay. This video illustrates the physical wiring process and initial setup.

5. Дастурҳои истифодабарӣ

The GRT6-B2 relay offers adjustable delay functions. Follow these steps to configure and operate your device.

5.1 Function Modes

The GRT6-B2 supports two main function modes:

  • A: Delay ON: The output contacts close after a set delay time once power is applied.
  • B: Delay OFF: The output contacts open after a set delay time once the trigger signal is removed or power is disconnected.
GEYA GRT6-B2 Delay ON and Delay OFF function diagrams
Figure 5: Timing diagrams illustrating the A (Delay ON) and B (Delay OFF) functions. These diagrams show how the output (R) responds to the input voltage (Un) and trigger signal (S) over time.

5.2 Танзими вақт

The delay time is set using two rotary knobs on the front panel: one for time range and one for percentage.

GEYA GRT6-B2 How to set time
Figure 6: Instructions on how to set the delay time. First, select the desired time range (e.g., 10m for 10 minutes). Second, adjust the percentage knob (e.g., 50%) to achieve the precise delay (e.g., 5 minutes for 10m range at 50%).

5.3 Нишондиҳандаҳои LED

  • LED сабз: Ҳолати таъминоти барқро нишон медиҳад.
  • LED сурх: Indicates the working status of the relay (e.g., timing in progress, output active).

6. Нигоҳдорӣ

The GEYA GRT6-B2 time relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity and proper function.

  • Тозакунӣ: Дастгоҳро тоза ва аз чангу хошок тоза нигоҳ доред. Барои тоза кардан матои хушк ва мулоимро истифода баред. Моеъҳои тозакунандаро истифода набаред.
  • Санҷиш: Periodically inspect wiring connections to ensure they are secure and free from corrosion. Check for any signs of physical damage or overheating.
  • Муҳити зист: Боварӣ ҳосил кунед, ки муҳити корӣ дар ҳудуди муқарраршудаи ҳарорат ва намӣ боқӣ мемонад, то аз шикасти бармаҳал пешгирӣ кунад.

7. Баррасии мушкилот

If the GEYA GRT6-B2 relay is not functioning as expected, consider the following common issues:

  • No Power Indication (Green LED Off): Check the power supply connections (A1, A2) and ensure the voltage is within the specified range (AC/DC 24V-240V).
  • Relay Not Activating/Deactivating:
    • Verify the function mode (A or B) is correctly selected.
    • Check the time range and percentage танзимот.
    • Ensure the trigger signal (S) is correctly applied for Delay OFF functions.
    • Inspect load connections and ensure the load is functioning correctly.
  • Вақти нодуруст: Re-check the time range and percentage settings. Ensure the knobs are firmly set to the desired values.
  • Аз ҳад зиёд гармшавӣ: If the device feels excessively hot, check the load current to ensure it does not exceed the relay's maximum rating (10A/AC1).

If problems persist after checking these points, contact a qualified electrician or the manufacturer for assistance.

8. Мушаххасоти

Detailed technical specifications for the GEYA GRT6-B2 time relay.

GEYA GRT6-B2 Technical Parameters Table
Figure 7: Comprehensive table of technical parameters for GRT6-A1/B1, GRT6-A2/B2, and GRT6-At/Bt models. This includes function, supply terminals, voltage range, burden, power input, supply voltage tolerance, supply indication, time ranges, time setting, time deviation, repeat accuracy, temperature coefficient, output, current rating, switching voltage, minimum breaking capacity DC, output indication, mechanical life, electrical life (AC1), reset time, operating temperature, storage temperature, and mounting type.
GEYA GRT6-B2 General Specifications
ПараметрАрзиш
БрендГЕЯ
МоделиGRT6-B2
ФунксияDelay ON (A), Delay OFF (B)
Терминалҳои таъминотА1-А2
Ҷилдиtage ДиапазонAC/DC 24V-240V (50-60Hz)
Вуруди нерӯAC max. 6VA/1.9W
Диапазони вақт0.1s - 10 days (ON, OFF)
Танзими вақтПотенциометр
Натиҷа2xSPDT (2NO2NC)
Рейтинги ҷорӣ10A/AC1
Гузариш ҷилдиtage250VAC/24VDC
Ҳарорати корӣ-20°C то +55°C (-4°F то 131°F)
Ҳарорати нигоҳдорӣ-35°C то +75°C (-22°F то 158°F)
МонтажDIN rail EN/IEC 60715
Андозаҳо (L x W x H)64мм x 18мм x 95мм (тақрибан)
Вазнтахминан. 2.08 унс

9. Кафолат ва дастгирӣ

For warranty information, please refer to the documentation provided with your purchase or contact your seller. If you require technical support or have questions regarding the GEYA GRT6-B2 time relay, please reach out to the manufacturer or authorized distributor.

Ҳуҷҷатҳои марбут - GRT6-B2

Пешview GEYA GRT6 Series Single-Function Time Relay: Instruction Manual & Technical Specifications
Detailed instruction manual and technical specifications for the GEYA GRT6 Series single-function time relays (GRT6-A, GRT6-B). Covers applications, features, wiring diagrams, and technical parameters.
Пешview Релеи вақтӣ GEYA GRT8-EC - Хусусиятҳо ва хусусиятҳои техникӣ
Detailed technical specifications, features, and operational guidance for the GEYA GRT8-EC time relay. This relay is designed for industrial automation, controlling lighting, heating elements, motors, and fans, offering adjustable delay times and DIN rail mounting.
Пешview Эстафетаи вақти бисёрфунксионалии GEYA GRT8-M - Дастури дастур
Дастури дастурии мукаммал барои релеи бисёрфунксионалии GEYA GRT8-M, ки тафсилоти замимаҳои он, мушаххасоти техникӣ, функсияҳо, ноқилҳо ва насбро дар бар мегирад.
Пешview Дастури истифодабарии релеи вақтӣ барои бисёрфунксионалии GEYA GRT8-M
Дастури истифода барои релеи вақти бисёрфунксионалии GEYA GRT8-M, ки дар он истифодаҳо, хусусиятҳо, мушаххасоти техникӣ, вазифаҳо, андозаҳо ва диаграммаҳои симкашии он муфассал шарҳ дода шудаанд. Дастур оид ба насб ва танзим пешниҳод мекунад.
Пешview GEYA GRLE8-01 Earth Leakage Relay: Instruction Manual & Technical Specifications
Comprehensive instruction manual for the GEYA GRLE8-01 Earth Leakage Relay. Details applications, technical parameters, wiring diagrams, panel layout, testing procedures, dimensions, and ZCT accessory options for electrical safety monitoring.
Пешview Дастури истифодабарии релеи вақтии велосипедрони асимметрӣ GEYA GRT8-S
Instruction manual for the GEYA GRT8-S Asymmetric Cycler Time Relay. Covers applications, function features, technical specifications, panel and wiring diagrams, and setting instructions for ventilation, lighting, and pump control.