NORDEN-логотип

NORDEN NFA-T01LM Loop Extension Module

NORDEN-NFA-T01LM-Loop-Extension-Module-fig-1

Маълумот оид ба маҳсулот

Мушаххасоти

  • Мутобиқат: EN 54 Part 18 (European Standard)
  • Вуруди ҷилдиtage: DC24V
  • Bus Input Range: 1000м

Дастурҳои истифодаи маҳсулот

Насбкунӣ

  • Омодасозии насб
    This interface module must be installed, commissioned, and maintained by qualified or factory-trained service personnel. Ensure compliance with all local codes in your area or standards like BS 5839 Part 1 and EN54.
  • Монтаж ва кабелӣ
    1. Install the loop extension module where anti-interference is needed or for extending bus communication distance within 1000m.
    2. Securely fix the module with screws in a suitable location.
    3. Refer to the external wiring terminal diagram for proper wiring.

Loop Extension Module Configuration

  • Outline Dimension Chart
    Refer to the outline dimension chart for the physical size of the loop extension module.
  • Принсипи кор
    The loop extension module collects bus signals, processes them through the MCU to output a standard bus waveform. The signal isolation circuit extends the bus communication distance and corrects the bus waveform through an optocoupler.

РАҲДДИҲ 
Ҳамаи ҳуқуқ маҳфуз аст.
Маълумот дар ин ҳуҷҷат бояд бидуни огоҳӣ тағир дода шавад

Бехатарии маҳсулот 
Барои пешгирии ҷароҳати вазнин ва талафоти ҷони ё молу мулк, пеш аз насб кардани детектор дастурҳоро бодиққат хонед, то кори дуруст ва бехатари системаро таъмин кунед.

Муқаддима

Барview

  • The NFA-T01LM Loop Extension Module operates on a DC24V power supply and utilizes an internal electrical isolation circuit to achieve real-time isolation and transmission of input and output bus signals, delivering a standard bus waveform. This module enhances the bus’s resistance to interference and helps extend the communication range. It is particularly effective in environments where external interference occurs or where longer communication distances are required.
  • Compliant with EN 54 Part 18 (European Standard), the unit features a discreet design suitable for modern buildings. Its plug-in assembly allows easy installation and maintenance. Fully compatible with the NFA-T04FP Intelligent Addressable Fire Alarm Control Panel, it ensures seamless addressable communication without compatibility issues.

Хусусиятҳо ва манфиатҳо

  • Мутобиқати EN54-18
  • Built-in MCU processor
  • Input bus, the output bus signal between the electrical isolation, electromagnetic interference has a good inhibitory capacity, stable and reliable work. Input Fire or Supervisory signal configuration.
  • Нишондиҳандаи ҳолати LED
  • To correct the bus signal, the output standard bus waveform
  • Fast intelligent bus output short circuit judge function, bus output short circuit protection function; after the bus is normal, it can recover the bus output in time
  • Тарҳрезии аз ҷиҳати эстетикӣ ҷолиб

Мушаххасоти техникӣ 

Мутобиқат EN 54-18: 2005
Вуруди ҷилдиtage Loop Power:24VDC [16V to 28V]

External PSU: 20 to 28VDC

Истеъмоли ҷорӣ Loop: ≤5mA

External PSU: ≤500mA

Bus input range: ≤1000m Bus output range: ≤1000m
Most cascade се
Protocol/Addressing Norden, Value ranges from 1 to 254
Ҳолати нишондиҳанда Normal: Single blink/Fault: Steady-on
Material / Colour Metal / Gray
Dimension / LWH 155.0мм×97.0мм×40.0мм
Ҳарорати корӣ -10°С то +55°С
Намӣ 0 to 95% Relative Humidity, Non-condensing

Насбкунӣ

Омодасозии насб
This interface module must be installed, commissioned, and maintained by a qualified or factory-trained service personnel. The installation must be installed in compliance with all local codes having jurisdiction in your area, or BS 5839 Part 1 and EN54.

Монтаж ва симгузаронй

  1. The loop extension module is used for anti-interference. When used outside the site should be installed in the presence of disturbances, such as the shielding effect of the iron shell. , extension module as an extended bus communication distanc, is used; it should be installed at the output end of long long-distance bus controller within 1000m; fixed by screws, installed in the room.
  2. The external wiring terminal diagram is shown below:

    NORDEN-NFA-T01LM-Loop-Extension-Module-fig-1

    • D1, D2: 24В терминали вуруди барқ
    • I1, I2: Bus input terminal
    • 01, 02: Bus output terminal, 01 is the positive, 02 is the negative.
    • Талаботи ноқил: no polarity signal, two buses using RVS twisted pair,
    • Sectional area≥1.0mm²;
    • DC24V power using BV line, Sectional area≥1.5mm²
      NOTE: The NFA-T01LM cannot be used in the loop.

Loop extension module configuration

Outline dimension chart

NORDEN-NFA-T01LM-Loop-Extension-Module-fig-3

Принсипи кор
The loop extension module collects the bus signal through the bus transceiver circuit, and outputs the control bus output circuit after the MCU processes the standard bus waveform; the signal isolation circuit bus input and output through an optocoupler can extend the bus communication distance and can correct the bus waveform.

Истифода ва амалиёт

  1. The use of the loop extension module must follow the following requirements:
    Meet the technical parameters defined in this specification
  2. After the loop extension module is installed, or in the use of the process to be tested every six months, the test method is as follows:
    1. The fire alarm controller is used to connect the front-end coding device with the extension module, and the coding equipment should be able to log in correctly.
    2. The detector, which is connected to the bus through the extension module is reports to the fire alarm, and the controller should be able to receive the alarm information correctly.

Муомилот ва нигоҳдорӣ
Transport, storage, and handling equipment shall be carried out in a packing condition. Loading and unloadprocessescess must be handled with care to prevent collision damage. StorageThehe environment shouldmaintainedn ventilation, dry, and avoid open storage.

Нигоҳдории умумӣ

  • Пеш аз гузаронидани таъмир ба кормандони мувофиқ хабар диҳед.
  • Disable the loop extension module on the control panel to prevent false alarms.
  • Do not attempt to repair the circuitry of the loop extension module; it may affect the operation to respond to a fire condition and will void the manufacturer’s warranty.
  • Notify again proper personnel after conducting the maintenance, and make sure to enable the loop extension module and confirm if up and running.
  • Perform the maintenance semiannually or depending on the site conditions.

Мулоҳизаҳои асосӣ

  • On-duty personnel should be familiar with the operation of the equipment, not the wrong operation.
  • This module for fire protection products must strictly implement the duty system and the shift in use, and make a running record.
  • Not every half a year is a function of the module test.

Замимаи 1

Limitations of the Loop extension module

  • The loop extension module cannot last forever. To keep the loop extension module working in good condition, please maintain the equipment continuously according to recommendations from manufacturers and relevant national codes and laws. Take specific maintenance measures based on different environments.
  • This loop extension module contains electronic parts. Even though it is made to last for a long period of time, any of these parts could fail at any time. Therefore, test your module at least every half-year according to national codes or laws. Any loop extension module, fire alarm devices, or any other components of the system must be repaired and/or replaced immediately as they fail.

ДАР БОРАИ ШИРКАТ

Саволҳои зуд-зуд додашаванда

Ҳаҷми вуруд чистtage requirement for the NFA-T01LM Loop Extension Module?

The module operates on a DC24V power supply.

How far can the bus input range of the module extend?

The bus input range can extend up to 1000m.

Ҳуҷҷатҳо / Сарчашмаҳо